![Mitsubishi Electric FR-A7AR E Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/mitsubishi-electric/fr-a7ar-e/fr-a7ar-e_instruction-manual_239761021.webp)
16
INSTALLATION AND WIRING (FR-E700 SERIES (E kit))
(4) Correctly install the insulating sheet between the inverter and plug-in option. (Refer to
page
installation method of an insulation sheet.)
(5) Securely fit the connector of the plug-in option to the inverter connector along the guides.
(6) Securely fix the both top and bottom of the plug-in option to the inverter with the accessory mounting
screws. (tightening torque 0.45N
m to 0.55N
m) If the screw holes do not line-up, the connector may
not have been plugged snugly. Check for loose plugging.
(7) Remove the PU cover provided on the front cover for plug-in option and install the other PU cover,
which was removed in (2).
(8) When wiring to the plug-in option is completed, install the front cover for plug-in option to the inverter.
(9) Install the option small cover to the front cover 1.
(10) Install the front cover 1 to the inverter.
(5) Option connector of inverter
(6) Mounting screws
Front cover for
plug-in option
plug-in option
(8)
Option small cover
(9)
(10)
(4)
(7) Replace
Insulation sheet