6. PARAMETER DEFINITIONS
6.1 IND = 0000h, Real-Time Monitor Area
*1 Bit-Map for PNU = Eh Input Terminal Monitor:
*2 Bit-Map for PNU = Fh Output Terminal Monitor:
The bit-wise data here reflect Pr.190 to Pr.195. If the assignments for the
terminals are changed, the bit-map may not be the same.
PNU
Definition
Minimum Setting
Increments
A500/F500 A500L/F500L
0h
Output frequency
0.01Hz
0.01Hz
1h
Output Current
0.01A
0.1A
2h
Output Voltage
0.1V
0.1V
4h
Frequency Setting
0.01Hz
0.01Hz
5h
Running Speed
1 r/min
1 r/min
6h
Motor Torque (0.1%)
0.01%
0.01%
7h
Converter Output Voltage
0.1V
0.1V
8h
Regenerative Brake Duty
0.1%
0.1%
9h
Electronic Overcurrent Protection Load
Factor
0.1%
0.1%
Ah
Output Current Peak Value
0.01A
0.1A
Bh
Peak Voltage
0.1V
0.1V
Ch
Input Power
0.01kW
0.1kW
Dh
Output Power
0.01kW
0.1kW
Eh
Input Terminal (*1)
Fh
Output Terminal (*2)
10h
Load Meter
11h
Motor Excite Current
0.01A
0.1A
12h
Position Pulse
13h
Cumulative Energy Time
1 h
1 h
15h
Orientation Status
16h
Actual Operation Time
1 h
1 h
17h
Motor Load Factor
0.1%
0.1%
18h
Cumulative Power
1kWh
1kWh
15-12
11
10
9
8
7
6
5
4
3
2
1
0
0
CS
RES STOP MRS JOG
RH
RM
RL
RT
AU
STR STF
15-6
5
4
3
2
1
0
0
Relay
FU
OL
IPF
SU
RUN