PRECAUTIONS  

 

(1)  For wiring to the terminal block, refer to the manual of the connected programmable controller module, 

published by Mitsubishi Electric Corporation. 

 

 12

COVERAGE OF WARRANTY   

 

If any fault or defect (hereinafter referred to as “failure”) attributable to us occurs within the terms of the product 
warranty, we shall replace the product free of charge via your local sales office. 
 

Terms of warranty 

The terms of the product warranty shall be one (1) year from the date of purchase or the delivered day to the 
designated place. 
 

Scope of warranty 

(1) The scope of warranty shall be limited to normal use based on the usage conditions, methods and 

environment, the specifications, or safety precautions of the product, etc., defined in the instruction manuals. 

(2) The following conditions are not covered with the warranty and subject to charge the product replacement, 

even if the valid warranty period remains. 

1) Failure resulting from inappropriate storage or handling, carelessness or negligence by customer, or failure 

caused by customer's hardware or software design. 

2) Failure caused by unapproved modifications, etc., to the product by customer. 
3) Failure that could have been avoided if, when our product was assembled into customer's device, 

safeguards defined by legal regulations applicable to customer's device or functions or structures 
considered standard by the industry had been provided. 

4) Failure recognized as preventable if the consumed products specified in instruction manuals, etc., were 

normally maintained or replaced. 

5) Replacement of consumable parts (relays, etc.). 
6) Failure caused by external factors beyond anyone’s control such as fires or abnormal voltage, and failure 

caused by force majeure such as earthquakes, lightning, or wind and water damage. 

7) Failure caused by reasons unpredictable by scientific technology standards at shipment from our factory. 
8) Any other failure not attributable to us or which customer identifies not attributable to us. 
 

 13. EXCLUSION

 

FROM LIABILITY FOR OPPORTUNITY LOSS AND SECONDARY LOSS

 

Regardless of the warranty period, we shall have no liability for compensation for any damage caused by 
reasons not attributable to MEE, any opportunity loss or lost profit caused by a failure of our products, any 
damage or secondary damage caused by special circumstances whether or not foreseeable, any accident, any 
damage of other manufacturers products, or any customer's work such as products replacement, readjustment 
or launch of local machinery equipment, etc. 

 
 
 

Содержание FA-TH16XRA20S

Страница 1: ...h this product only For programmable controller system safety precautions refer to the user s manual of the programmable controller used In this manual the safety precautions are classified into two levels WARNING and CAUTION WARNING Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury CAUTION Indicates that incorrect handling may cause hazardous con...

Страница 2: ...current or an overcurrent caused by a load short circuit flows for a long time it may cause smoke and fire To prevent this configure an external safety circuit such as a fuse Configure a circuit to turn on the programmable controller and then the external power supply If the external power supply is turned on first an accident may occur due to an incorrect output or malfunction Design Precautions ...

Страница 3: ...que range Undertightening can cause the product to drop short circuit or malfunction Overtightening can damage screws and or the product causing the product to drop short circuit or malfunction Be sure to shut off the external power supply for the system in all phases before installing or removing the product Failure to do so may damage the product or cause the product to malfunction or fail Do no...

Страница 4: ... so may cause a malfunction When disconnecting a cable from the product do not pull the cable itself For a cable with connector hold the connector and pull it out For a cable connected to a terminal block loosen the terminal block screws before removing the cable Failure to do so may result in a malfunction or damage to the product or cable Before connecting the cables check the type of interface ...

Страница 5: ...use of the product do not mount remove the module and the cable more than 50 times IEC 61131 2 compliant respectively Exceeding the limit of 50 times may cause malfunction Startup and maintenance of a control panel must be performed by qualified maintenance personnel with knowledge of protection against electric shock Lock the control panel so that only qualified maintenance personnel can operate ...

Страница 6: ...res must issue an EC Declaration of Conformity and the products must bear a CE marking 1 Authorized representative in Europe The authorized representative in Europe is shown below Name Mitsubishi Electric Europe B V Address Mitsubishi Electric Platz 1 40882 Ratingen Germany 2 How to use the FA Goods in compliance with the EMC and Low Voltage Directives For information on how to conform to the EMC ...

Страница 7: ...CATIONS 4 CONNECTED TARGET MODEL PLC MODULE CONNECTION CABLE 7 INSTALLATION METHOD 11 PRECAUTIONS 12 COVERAGE OF WARRANTY 13 EXCLUSION FROM LIABILITY FOR OPPORTUNITY LOSS AND SECONDARY LOSS FOR YOUR SAFETY Japanese manual number 50D FA9010 009 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation can...

Страница 8: ...tinuous vibration 5 to 8 4Hz 1 75mm 8 4 to 150Hz 4 9m s2 0 5G Shock resistance Compliant with JIS B 3502 and IEC61131 2 147m s2 15G 3 times each in X Y and Z directions Operating atmosphere No corrosive gas Operating altitude 1 2 000m or lower Installation location Inside the control panel Overvoltage category 2 II or lower Pollution level 3 2 or lower 1 Do not use or store the module under the at...

Страница 9: ...ernal supply power 24 VDC 10 ripple factor within 5 CLASS 2 Module consumption current Approx 10mA when 24 VDC not inc PLC consumption current Dielectric withstand voltage insulation resistance Between eac input between external power supply and inputs 2500 VAC 1 minute 10MΩ or higher Withstand noise Simulator noise 500 Vp p noise width 1 μs based on noise simulator with noise frequency of 25 to 6...

Страница 10: ...tor type A1SX41 Note 2 A1SX41 S1 A1SX41 S2 A1SX42 Note 2 A1SX42 S1 A1SX42 S2 FA CBL FM2V Note 1 FA CBL FM2LV Note 1 A1SH42 Note 2 A1SH42 S1 A1SH42P Note 2 A1SH42P S1 Input side FA CBL FM2V Note 1 FA CBL FM2LV Note 1 CC Link connector type AJ65SBTCF1 32D AJ65BTC1 32D At positive common FA CBL FM2H Note 1 FA CBL FM2LH Note 1 MELSEC F Series MELSEC iQ F Series Connector type FX2NC 16EX FX2NC 32EX FX3...

Страница 11: ...ries module from our MEEFAN website and replace the sheet as needed URL http www mee co jp sales fa meefan parts cad fa_goods cad_list html Terminal block symbol paper MELSEC iQ R and MELSEC Q series Hexadecimal Note 5 Front Back MELSEC iQ F and MELSEC F series Octal Downloadable from our website Front Back Note 5 This sheet is attached to the module Note 6 When using the MELSEC iQ F or MELSEC F s...

Страница 12: ...12 6 MODULE MOUNTING ORIENTATION Horizontal mounting Vertical mounting ...

Страница 13: ...1 1 When cable with terminal block is used Attach the terminal block securely to the PLC module with attachment screws Programmable controller module QX40 other Insert the connector to the back and then fully secure the connector with a clip Connection cable FA CBL TMV20 Switch etc ...

Страница 14: ... Switch etc Insert the connector to the back and then fully secure the connector with a clip Programmable controller module QX40 other Attach the power wires securely to the PLC module terminal block Connection cable FA CBL M20 FA CBL YM20 ...

Страница 15: ...tor to the programmable controller module using the mounting screws Programmable controller module QX41 other Insert the connector to the back and then fully secure the connector with a clip Connection cable FA CBL FM2V FA CBL FM2LV FA CBL FM2H FA CBL FM2LH Insert the connector to the back and then fully secure the connector with a clip Switch etc Switch etc ...

Страница 16: ...16 7 2 2 When a 20P connector cable is used ...

Страница 17: ...17 8 EXTERNAL CONNECTION EXAMPLE 9 HOW TO DISMOUNT AND SET THE DEVICE REMOVE ...

Страница 18: ...ESS TERMINALS Solderless terminal dimensions Unit mm Round non insulated solderless terminal Round insulated solderless terminal Y non insulated solderless terminal Y insulated solderless terminal Terminal block shape Unit mm ...

Страница 19: ...3 Failure that could have been avoided if when our product was assembled into customer s device safeguards defined by legal regulations applicable to customer s device or functions or structures considered standard by the industry had been provided 4 Failure recognized as preventable if the consumed products specified in instruction manuals etc were normally maintained or replaced 5 Replacement of...

Страница 20: ...tation atomic power electric power aerospace or medical applications please contact your nearest Mitsubishi sales representative Although this product was manufactured under conditions of strict quality control the product shall be systematically provided with backup and fail safe functions when it is used in facilities where breakdowns of the product are likely to cause a serious accident or dama...

Отзывы: