47
SYSTEM SET-UP
Inserting desired temperatures
Once the required modes have been activated the required temperatures need to be inserted, this is a separate process that
FDQEHFRPSOHWHGXVLQJWKHIROORZLQJVWHSV7KHUHFRPPHQGHGVHWWLHDWLQJ(&2µFDQEHIRXQGRQSRW
:DWHUµSDJH
Normal
Display
Step 2:
7KH ILUVW RSWLRQ ZLOO EH ¶ZDWHU WHPS KHDWLQJ·
Each time button E is pressed it will move to the
next available mode.
Water Temp
Heating
Water Temp
Heating Eco
No.1
Water Temp
Heating Eco
No.2
Water Temp
Hot Water
Water Temp
Anti-Freeze
Water Temp
Cooling
Temp Offset
Heating
Temp Offset
Cooling
Note:
These options
can be disre-
garded. They
might have
been removed
or disabled.
Step 1:
From the regular display holding button H will
activate the controller. The display will flash
ZLWKWKHZRUGV¶ORDGLQJ·
Desired
Temperature
Step 3:
The up and down F buttons can be
used to select the desired temperature.
Pressing button E will move to next
available mode. Temperature changes of
that mode can then be made.
Desired
Temperature *
Desired
Temperature *
Desired
Temperature
H
E
E
E
E
E
E
E
E
E
E
E
E
F
F
F
F
1
2
3
4
¶6HWWLQJV·
Normal
Display
A
H
Step 4:
From any of the modes in step 3,
pressing button A will memorise these
VHWWLQJV 7KH VFUHHQ ZLOO IODVK ¶VHWWLQJV·
for several settings. Holding down button
H will end the set-up.
There are a selection of modes on the controller that the end user can choose for set-up purposes; please note that some of
these may have been removed or disabled for use with the Ecodan unit. From the normal display it will always skip progress
WR¶ZDWHUWHPSKHDWLQJ·HDFKSUHVVRIEXWWRQ(ZLOOVNLSWRWKHQH[WDYDLODEOHPRGH:KHQVHWWLQJXSWKHFRQWUROOHUSUHVVLQ
g
button A must be used to memorize the settings.
How to lock the Buttons
:KLOHKROGLQJGRZQWKHEXWWRQ$SUHVVDQGKROGGRZQWKHEXWWRQ,IRUVHFRQGV7KH´/RFNHGµLQGLFDWLRQDSSHDUVRQWKH
screen (display 8), indicating that the lock is now engaged.
,IORFNLQJKDVEHHQGLVDEOHGLQ)XQFWLRQ6HOHFWLRQRIUHPRWHFRQWUROOHUWKHVFUHHQZLOOGLVSOD\WKH´1RW$YDLODEOHµPHVVDJH
ZKHQ\RXSUHVVWKHEXWWRQVDVGHVFULEHGDERYH,I\RXSUHVVDORFNHGEXWWRQWKH´/RFNHGµLQGLFDWLRQGLVSOD\ZLOOEOLQNR
n
the display.
How to Unlock the Buttons
1. While holding down the button A press and hold down the button I for 2 seconds
³
so
WKDWWKH´/RFNHGµLQGLFDWLRQGLVDSSHDUVIURPWKHVFUHHQGLVSOD\
Fig. 4.6
Throughout the system set-up buttons on the controller are referenced by letters and displays by numbers ; this key can be found on page 41