diMEnSiOnS
Upper View
Front View
Upper View
Front View
PUHZ-W50VHA2(-BS)
PUHZ-W85VHA2(-BS)
Upper View
Front View
Product Information
Heating
PUHZ-(H)W50-140VHA(2)/YHA2(-BS)
Ecodan Monobloc Air Source Heat Pumps
A++
127%
3.25
A++
162%
4.12
A
99%
4.8
1.63
2.95
-15 ~ +35°C
45
40
22
14.3
12
950
330+30
*5
740
64
220-240v, 50Hz
Single
5.4 [13]
16
A++
128%
3.27
A++
162%
4.12
A
97%
8.3
2.96
2.80
-20 ~ +35°C
48
42
22
25.8
13.5
950
330+30
*5
943
77
220-240v, 50Hz
Single
10.3 [23]
25
A++
126%
3.22
A++
157%
3.99
A
96%
14.0
4.81
2.91
-25 ~ +35°C
53
46
28
40.1
9
1020
330+30
*5
1350
134
220-240v, 50Hz
Single
14.9 [35]
40
A++
126%
3.22
A++
157%
3.99
A
96%
14.0
4.81
2.91
-25 ~ +35°C
53
46
28
40.1
9
1020
330+30
*5
1350
148
380-415v, 50Hz
3
5.1 [13]
16
HEAT PUMP SPACE
HEATER - 55˚C
HEAT PUMP SPACE
HEATER - 35˚C
HEAT PUMP COMBINATION
HEATER - Large Profile
*1
HEATING
*2
(A-3/W35)
OPERATING AMBIENT TEMPERATURE (°C DB)
SOUND PRESSURE LEVEL AT 1M (dBA)
*3*4
LOW NOISE MODE (dBA)
*3
WATER DATA
DIMENSIONS (mm)
*7
WEIGHT (kg)
ELECTRICAL DATA
ErP Rating
ɳ
s
SCOP
ErP Rating
ɳ
s
SCOP
ErP Rating
ɳ
wh
Capacity (kW)
Power Input (kW)
COP
Pipework Size (mm)
Flow Rate (l/min)
Water Pressure Drop (kPa)
Width
Depth
Height
Electrical Supply
Phase
Nominal Running Current [MAX] (A)
Fuse Rating - MCB Sizes (A)
*6
OUtdOOr Unit
PUHZ-W50VHA2(-BS) PUHZ-W85VHA2(-BS)
PUHZ-HW140VHA2(-BS) PUHZ-HW140YHA2(-BS)
A++
125%
3.20
A++
164%
4.18
A
100%
11.0
3.65
3.01
-20 ~ +35°C
53
46
28
32.1
6.3
1020
330+30
*5
1350
133
220-240v, 50Hz
Single
11.2 [29.5]
32
PUHZ-W112VHA(-BS)
*1 Combination with EHPT20X-MHCW Cylinder
*2 Under normal heating conditions at outdoor temp: -3°CDB / -4°CWB, outlet water temp 35°C, inlet water temp 30°C.
*3 Under normal heating conditions at outdoor temp: 7°CDB / 6°CWB, outlet water temp 35°C, inlet water temp 30°C as tested to BS EN14511.
*4 Sound power level of the PUHZ-W50VHA2 is 61dBA, PUHZ-W85VHA2 is 62.5dBA, PUHZ-W112VHA is 65dBA, PUHZ-HW140VHA2 is 65.5dBA, PUHZ-HW140YHA2 is 67.5dBA. Tested to BS EN12102.
*5 Grille.
*6 MCB Sizes BS EN60898-2 & BS EN60947-2.
*7 Flow Temperature Controller (FTC) for standalone systems PAC-IF062B-E Dimensions WxDxH (mm) - 520x150x450
Printed on September 26th 2015 SAP No. 282526
UNITED KINGDOM Mitsubishi Electric Europe
Living Environmental Systems Division
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881
IRELAND Mitsubishi Electric Europe
Westgate Business Park, Ballymount, Dublin 24, Ireland
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Telephone:
01707 282880
email:
web:
heating.mitsubishielectric.co.uk
Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2015. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the
right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing
and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to
the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
ɳ
s
is the seasonal space heating energy efficiency (SSHEE)
ɳ
wh
is the water heating energy efficiency
PUHZ-(H)W112-140VHA(2) / YHA2(-BS)
Содержание ecodan PUHZ-W50VHA2
Страница 4: ...2 ...
Страница 14: ...11 INSTALLATION Pipe Work Schematic Single Zone Fig 2 0 12 ...
Страница 15: ...12 INSTALLATION Pipe Work Schematic Twin Zone Fig 2 1 13 ...