8
Cylinder Technical Data
12
Pre-Plumbed Slimline Cylinder Installation Manual
PRE-PLUMBED SLIMLINE CYLINDER UNIT
ECOSLIM-
180L-PP-MEUK
ECOSLIM-
150L-PP-MEUK
Nominal hot water volume (litres) 150 180
Water Flow Rate (l/min) W50 - W85 14.3 - 25.8 14.3 - 25.8
Pump 1 x Grundfos UPS2 25-60 1 x Grundfos UPS2 25-60
Connection Size (mm) Heating / DHW (mm) 22 22
Primary Expansion Vessel (Litres) 12 19
Charge Pressure (MPa (Bar)) 0.3 (3) 0.3 (3)
Water Safety Devices Water Circuit Control Thermistor (°C) 1 - 80 1 - 80
Pressure Relief Valve (MPa (Bar)) 0.3 (3) 0.3 (3)
Expansion Relief Valve (Cold) 0.6 (6) 0.6 (6)
DHW Tank Control Thermistor 40-70 40-70
High Limit Stat (°C) Mechanical 80 Mechanical 80
Temp and Pressure Relief Valve (°C)/ (MPa (Bar)) 90 / 0.7 (7) 90 / 0.7 (7)
Dimensions (mm) Width 475 475
Depth 565 565
Height 1880 1950
Weight empty/full (kg) 65.5 / 215.5 69.5 / 249.5
Cylinder Material Tank Cylinder Material Stainless Steel Stainless Steel
Heating Surface Area (m
2
) 2 3
Insulation Insulation Type
Polyurethane (PU) Insulation with CO
2
Blowing Agent
Insulation Thickness (mm) 50 50
Standing Heat Loss (kWh/24hrs) 1.31 1.6
GWP of Insulation 0 0
ODP of Insulation Less than 5 Less than 5
Electrical Data Control Board Electrical Supply 220-240v, 50Hz 220-240v, 50Hz
Phase Single Single
Fuse Rating - MCB Sizes (A)
*1
10 10
Electrical Supply 220-240v, 50Hz 220-240v, 50Hz
Phase Single Single
Capacity (kW) 3 3
Max Running Current (A) 13 13
Fuse Rating - MCB Sizes (A)
*1
16 16
Mechanical Zones DHW and 1 heating zone
*2
DHW and 1 heating zone
*2
Optional simplified wireless room thermostat and wireless receiver
PAR-WT50-E controller and PAR-WR51-E receiver
optionally
powered by
outdoor unit
Immersion
Heater
*1 MCB Sizes BS EN60898-2 & BS EN60947-2 *2 Optional 2 zone accessory available