Option 2: Cylinder unit powered by independent source.
If the cylinder unit and outdoor unit have separate power supplies, the following
requirements MUST be carried out:
• Change the connector connections in the control and electrical box of
the cylinder unit (see Figure 7-3)
• Turn the outdoor unit DIP switch SW8-3 to ON
• Turn on the outdoor unit BEFORE the cylinder unit.
L
N
S1
S2
S3
S1
S2
S3
TB1
L
N
ECB1
L
N
ECB2
L
N
Wiring
circuit
breaker
or
Isolating
switch
Power
supply
~/N
0V
50Hz
Earth
leakage
circuit
breaker
*1
Earth
leakage
circuit
breaker
*1
Wiring
circuit
breaker
or
Isolating
switch
Power
supply
~/N
0V
50Hz
Outdoor unit
Cylinder unit
Power
supply
~/N
0V
50Hz
Power
supply
~/N
0V
50Hz
Wiring
circuit
breaker
or
Isolating
switch
Wiring
circuit
breaker
or
Isolating
switch
For
booster
heater
(Primary circuit)
For
Immersion
heater
(DHW tank)
To control
board
<1 phase>
<Figure 7-4>
Electrical connections 1 phase
<Figure 7-3>
Description
Power supply
Capacity (Indoor unit Ref.) Breaker
Wiring
Booster heater (Primary circuit)
~/N 230 V 50 Hz
kW (EHPT0X-VMH*)
16 A *1
.5 mm²
6 kW (EH*T0X-VM6**)
A *1
6.0 mm²
Immersion heater (DHW tank)
~/N 230 V 50 Hz
kW (EH*T0*-VM*H*)
16 A *1
.5 mm²
Cylinder unit power supply
~/N 230 V 50 Hz
Cylinder unit input capacity
Main switch (Breaker)
*1
16 A
Wiring
Wiring No. × size (mm²)
Cylinder unit power supply
× Min. 1.5
Cylinder unit power supply earth
1 × Min. 1.5
Cylinder unit - Outdoor unit
*
× Min. 0.
Cylinder unit - Outdoor unit earth
—
Circuit
rating
Cylinder unit L - N
*
0V AC
Cylinder unit - Outdoor unit S1 - S
*
—
Cylinder unit - Outdoor unit S - S
*
4V DC
*1. A breaker with at least 3.0 mm contact separation in each pole shall be provided. Use earth leakage breaker (NV).
The breaker shall be provided to ensure disconnection of all active phase conductors of the supply.
*2. Max. 120 m
*.
The values given in the table above are not always measured against the ground value.
Note:
1. Wiring size must comply with the applicable local and national codes.
2. Indoor unit/outdoor unit connecting cords shall not be lighter than polychloroprene sheathed flexible cord. (Design 60245 IEC 57)
Indoor unit power supply cords shall not be lighter than polychloroprene sheathed flexible cord. (Design 60227 IEC 53)
3. Install an earth longer than other cables.
4. Please keep enough output capacity of power supply for each heater. Insufficient power supply capacity might cause chattering.
*1 If the installed earth leakage circuit breaker does not have an over-current protection function, install a breaker with that function along the same power line.
*2 Affix label B which is included with the manuals near each wiring diagram for cylinder unit and outdoor units.
OCH531