background image

F

2-9

&DUDFWp

UL

VWLT

XHVWHF

KQ

LT

XHV

3DUDPqWUDJ

H

(

7

(

97

(

7

Dim

ensions 

fa

c

e

 ava

n

t,

 Large

ur x

 

haut

eur 

x pr

of

ondeur

, m

m

.

367 

274 x

 6,

0

335 

430 x

 6,

0

290 x

 247 

5,

0

P

rof

ondeu

r d

’enc

ombrem

ent

, mm

S

ans l

e

 conne

ct

eur

 D-s

ub:

 90.

 

A

v

ec 

le

 conn

ect

e

u

r D-

sub:

 1

10.

Sa

ns 

le connec

teur D-s

ub:

 90.

 

A

v

ec 

le connec

teur D-s

ub:

 1

10.

Sans

 l

e

 c

onnect

eur D-s

ub:

 109.

 

A

v

ec

 le connect

eur D-sub

: 130.

D

é

c

oupe pour

 f

a

ce 

avant

V

o

ir 

sc

h

é

ma

S

3

-03028

S3

-03107

S3-

03142

P

rot

ec

ti

on de 

la f

a

ce

 avan

t du 

te

rmi-

nal

IP

 6

5

, NE

M

A

 4

P

rot

ec

ti

on 

du bor

ni

er

 arr

re

IP

 2

0

Carac

ri

s

tiques 

du 

clavier

M

embr

anes 

de clav

ie

r av

ec dis

que de 

press

ion polyes

ter

 prot

é

g

é

s p

a

r un 

fi

lm

 d

’A

u

to

te

x 2F

200 

im

prim

é

 sur la 

fa

ce arri

è

re - 

Dur

é

de vie 1 

m

illions d

’op

é

rat

ions

. See 

$SSHQGL[

%

.

F

a

ce arri

è

re du 

te

rm

in

al

A

c

ier bi

c

h

rom

a

te

 j

a

u

ne.

P

o

id

s

 S

ans l

e

 conne

ct

eur

 

D-s

u

b

3,

5 k

g

4,

0 k

g

3,

kg

Po

rt

 s

é

rie RS-4

22

Conn

ect

eur

 à

 25 br

oches 

fe

melle D-

sub av

ec 

fi

xation s

tandar

d p

a

r vis 

4-40 

UNC.

Po

rt

 s

é

rie RS-2

32

Conn

ect

eur

 à

 9 

br

oches m

â

le D-sub

 avec

 f

ixat

ion st

andard p

a

r vis 4-40 

U

NC.

R

é

s

e

rvat

io

n pour 

ext

ension

2

1

2

M

é

moire f

lash pour l

´applicat

ion

2

 Mb

Horloge t

e

m

p

s r

é

el

±

10 P

P

M

 + 

erreur

 due 

aux 

variat

ions

 de 

la t

e

mp

é

ra

tu

re am

bi

an

te

 et

 de 

la t

ens

io

n

 d

’aliment

at

ion.

 

E

rreur 

to

ta

le ma

ximale 1 

min.

/m

oi

s

 = 12 

min.

/an.

 Dur

é

de vie:

 10 ans

 de la bat

te

rie pour l

’horloge de 

te

m

p

s

 r

é

el

s

.

Содержание E900

Страница 1: ...inal drawings C 1 Cable drawings D 1 MITSUBISHI ELECTRIC AUTOMATION USA 1999 Mitsubishi Electric Automation absolves itself of all responsabilities for damage and injuries that may occur during installation or use of this equipment Mitsubishi Electric Automation absolves itself of all responsabilities for any type of modification made to the equipment ...

Страница 2: ...ran cantidad de campos de aplicación del equipo es responsabilidad del ususario la adquisición de los conocimientos necesarios para su correcta aplicación en cada caso concreto Mitsubishi Electric Automation USA se desresponsabilizan de los daños que puedan ocurrir durante la Instalación o uso del equipo Mitsubishi Electric Automation USA elude cualquier responsabilidad derivada de cualquier tipo ...

Страница 3: ...iones que se acompañan El equipo debe estar conectado a tierra tal como se describe en las instrucciones de instalación La instalación debe ser realizada por personal cualificado Los cables de alimentación señal y alta tensión deben estar suficientemente separados No monte el equipo en lugares donde reciba luz solar directa XUDQWH HO XVR Mantenga limpio el equipo Las paradas de emergencia y otras ...

Страница 4: ...mas mantenimiento de recetas y canales de tiempo Los terminales tienen una forma de trabajar básicamente orientada a objeto lo cual facilita bastante su utilización El terminal se programa directamente desde un ordenador personal con el paquete de software SW MTA WIN para Windows De ahora en adelante nos refer iremos al producto SW MTW WIN como el software del PC Todo el proyecto se alma cena en e...

Страница 5: ...ienda el uso del software del PC Para instalarlo con sulte el manual específico del producto Los parametros en el terminal y en el software del PC deben ajustarse de la misma manera 1RPEUH 86 Cable 1 MTA PROG C Cable 2 MTA D25 C Cable 3 MTA MINI D25 Cable 4 100 240 VAC E900T E900VT E910T Cable 1 56 56 Ordenador personal ...

Страница 6: ...LVWHP D 6LVWHPD R 1 Sistema A o QnA 15m Cable 2 15m Cable 2 CR01 RS 422 RS 232 Advertencia No válido para el sistema AnE sistema FX 56 56 15m Cable 2 15m Cable 2 CR01 15m Cable 3 or Cable 2 Cable 4 15m Cable 3 CR01 or Cable 2 Cable 4 CR01 56 56 Sistema FX0 o FX2N ...

Страница 7: ... RQH LyQ DO PyNXOR H Ver apéndice A para la configuración del módulo C24 8 4 4 1 6 5 6 8 5 56 56 CH1 E C24 232 CAB Ver apéndice D 56 56 CH2 E C24 422 CAB Ver apéndice D 56 56 CH2 E C24 422 CAB Ver apéndice D ...

Страница 8: ...E 1 7 6 5 6 8 5 6 4 5 6 4 56 56 Cable 1 56 56 56 56 CH1 Cable 1 CH2 E C24 422 CAB ...

Страница 9: ...poner del juego de carac teres IBM Consulte el manual de la impresora para una correcta configuración Si desea conectar el terminal a una impresora con un interfaz paralelo debe utilizar la tarjeta de expansión IFC PI Ver el manual de la tarjeta para más información 56 56 MAC PRINT CAB Impersora ...

Страница 10: ...GLFL Material parte posterio Chapa de acero cromada en amarillo Peso Excl conector D sub 3 5 Kg 4 0 kg 3 3 Kg Puerto serie RS 422 Conector hembra D sub de 25 pin montado sobre el chasis con tornillos de sujección estándar 4 40 UNC Puerto serie RS 232 Conector macho D sub de 9 pin montado sobre el chasis con tornillos de sujección estándar 4 40 UNC Slots de expansión 2 slots de expansión incorpora ...

Страница 11: ...vida 25000 h en temperature ambiente 25 C Pantalla táchi Tensión de alimentación 100 240 VAC Temperatura ambiente 0 a 50 C Temperatura de almacenamiento 20 a 70 C Humedad relativa Máx 85 sin condensación Tests EMC en el terminal El terminal cumpre las normas funddamentales del artículo ouarto de la directiva 89 336 EEC Probado según las normas EN50081 2 Emisión y EN50082 2 inmunidad 3DUDPHWHU 7 97...

Страница 12: ...s de cet équipement l utilisateur doit lui même acquérir les connaissances nécessaires pour utiliser correctement ces produits pour les applications particulières Mitsubishi Electric Automation USA se dégage de toutes responsabilités pour tous les dommages éventuels techni ques et corporels qui pourraient apparaître durant l installation ou l utilisation de ce produit Mitsubishi Electric Automatio...

Страница 13: ...ci Cet équipement doit être installé exclusivement par du personnel qualifié Les câbles haute tension et les câbles véhiculant un signal ou une alimentation basse tension doivent être séparés Le produit ne doit pas être monté sous un éclairage direct Q XWLOLVDWLRQ Conservez l équipement dans un état de propreté compatible avec le fonctionnement Les fonctions de sécurité et d arrêt d urgence ne dev...

Страница 14: ... des canaux horodateurs Le terminal est programmé directement par un PC avec le logiciel de programmation SW MTA WIN pour windows Dans les paragraphes suivants ce produit sera désigné comme le logiciel PC Le projet de programme est entièrement stocké dans le terminal Le terminal possède pour la plupart de ces fonctions un mode opératoire qui en facilite son utilisation Bascluez du mode operatión e...

Страница 15: ...andé d utiliser le logiciel PC Pour installer le logiciel PC référez vous au manuel de ce produit Il faut le paramètrage du logiael PC et du terminal soient les mênues 1RP 86 Cable 1 MTA PROG C Cable 2 MTA D25 C Cable 3 MTA MINI D25 Cable 4 100 240 VAC E900T E900VT E910T Cable 1 56 56 Personal computer ...

Страница 16: ...HW 4Q VHULHV VHULHV HW 1 VHULHV A et QnA system 15m Cable 2 15m Cable 2 CR01 56 56 Note Not valid for the system AnE FX system 45 56 15m Cable 2 15m Cable 2 CR01 15m Cable 3 ou Cable 2 Cable 4 15m Cable 3 CR01 ou Cable 2 Cable 4 CR01 56 56 FX0 et FX2N system ...

Страница 17: ...UWHV Consultez l appendice A pour la configuration du module C24 8 4 4 1 6 5 6 8 5 56 56 CH1 E C24 232 CAB Consultez l appendice D 56 56 CH2 E C24 422 CAB Consultez l appendice D 56 56 CH2 E C24 422 CAB Consultez l appendice D ...

Страница 18: ...F 2 7 6 5 6 8 5 6 4 5 6 4 56 56 Cable 1 56 56 56 56 CH1 Cable 1 CH2 E C24 422 CAB ...

Страница 19: ...semble de cara ctère IBM Se référer au manuel de l imprimante pour une configuration correcte Si vous voulez connecter le pupitre a l imprimante avec une uaison paralellee vous devez utiliser la carte d extension IFC PI Consultez le manuel pour le IFC PI pour plus d informations 56 56 MAC PRINT CAB Imprimante ...

Страница 20: ...branes de clavier avec disque de pression polyester protégés par un film d Autotex 2F200 imprimé sur la face arrière Durée de vie 1 millions d opérations See SSHQGL Face arrière du terminal Acier bichromate jaune Poids Sans le connecteur D sub 3 5 kg 4 0 kg 3 3 kg Port série RS 422 Connecteur à 25 broches femelle D sub avec fixation standard par vis 4 40 UNC Port série RS 232 Connecteur à 9 broche...

Страница 21: ... texte Rétro éclairage durée de vis 25000h a temperature 25 C Touch screen Alimentation 100 240 VAC Température de fonctionnement 0 50 C Température de stockage 20 70 C Humidité relative 85 maximum sans condensation Test EMC sur le terminal Le terminal est conforme avec l essentiel des protections demandées dans l article 4 de la directive 89 336 EEC Testé en accord avec EN50081 2 emission et EN50...

Страница 22: ...st acquire the appropriate knowledge needed to use the equipment correctly for particular applications Mitsubishi Electric Automation USA absolves itself of all responsibilities for damage and injuries that may occur during installation or use of this equip ment Mitsubishi Electric Automation USA absolves itself of all responsibilities for any type of modification made to the equipment Only approv...

Страница 23: ...lation instructions The product must be grounded according to the accompanying installation instructions This equipment must be installed by qualified personnel High voltage signal and supply cables must be separated The product should not be mounted in direct sunlight Q XVH Keep the equipment clean Emergency stop and other safety functions should not be controlled from the terminal Do not touch t...

Страница 24: ...e channels The terminal have for the most part an object oriented way of working which makes them easy to use The terminal can be programmed directly from the terminal or from a personal computer with the software package SW MTA WIN for Windows Hereafter the product SW MTA WIN is referred to as the PC software The whole programmed project is transferred to the terminal and stored in the terminal C...

Страница 25: ...d that the PC software is used To install the PC software see the manual for this product The communication parameters in the terminal and in the PC software should be set in the same way 1DPH 86 Cable 1 MTA PROG C Cable 2 MTA D25 C Cable 3 MTA MINI D25 Cable 4 100 240 VAC E900T E900VT E910T Cable 1 56 56 Personal computer ...

Страница 26: ...VHULHV VHULHV DQG 1 VHULHV A and QnA system 15m Cable 2 15m Cable 2 CR01 RS 422 RS 232 Not valid for the AnE system NOTE FX system 15m Cable 2 15m Cable 2 CR01 56 56 56 56 15m Cable 3 or Cable 2 Cable 4 15m Cable 3 CR01 or Cable 2 Cable 4 CR01 FX0 and FX2N system ...

Страница 27: ...RQ WR DQ PRGXOH LQ WKH 0 6 3 V VWHP See Appendix A for settings on an C24 module 8 4 4 1 6 5 6 8 5 56 56 CH1 E C24 232 CAB See appendix D 56 56 CH2 E C24 422 CAB See appendix D 56 56 CH2 E C24 422 CAB See appendix D ...

Страница 28: ...GB 3 7 6 5 6 8 5 6 4 5 6 4 56 56 Cable 1 56 56 56 56 CH1 Cable 1 CH2 E C24 422 CAB ...

Страница 29: ...quipped with IBM character set Refer to the printer manual for the correct configuration If you want to connect the terminal to a printer with a parallel interface you have to use the expansion card IFC PI See the manual for IFC PI for further information 56 56 MAC PRINT CAB Printer ...

Страница 30: ...nt on reverse side 1 million operations See SSHQGL Reverse side material Yellow chromated steel plate Weight Excl D sub 3 5 kg 4 0 kg 3 3 kg Serial port RS 422 25 pin D sub contact chassis mounted female with standard locking screws 4 40 UNC Serial port RS 232 9 pin D sub contact chassis mounted male with standard locking screws 4 40 UNC Expandion slot 2 1 2 Flash memory for application 2 Mb Real ...

Страница 31: ...5000 h at the ambient temperature of 25 C Touch screen Supply voltage 100 240 VAC Ambient temperature 0 to 50 C Storage temperature 20 to 70 C Relative humidity Max 85 non condensing EMC tests on the terminal Noise tested according to EN50081 2 emission and EN50082 2 immunity The terminal conforms with the essential protection requirements in article four of the directive 89 336 EEC 3DUDPHWHU 7 97...

Страница 32: ...ais Devido às diversas aplicações possiveis deste equipamento o utilizador deve adquirir os conhecimentos adequados necessários à sua utilização correcta em aplicações particulares À Mitsubishi Electric Automation USA não cabe responsabilidade alguma em caso de eventuais danos ocorridos durante a instalação ou uso deste equipamento A Mitsubishi Electric Automation USA não se responsabiliza por nen...

Страница 33: ...amento Deve ser estabelecida a ligação à terra conforme as instruções Este equipamento deve ser instalado por pessoal qualificado Os cabos de sinal e alimentação devem ser separados O produto não deve ser exposto directamente ao sol 1D XWLOL DomR Mantenha o equipamento limpo Paragem de emergência e outras funções de segurança não devem ser controladas a par tir do terminal Não toque as teclas o ec...

Страница 34: ...o dinâmica alarmes receitas e canais de tempo Os terminais possuem uma metodologia de programação orientada por objectos que os torna fáceis de usar O terminal é programado directamente do PC com o programa SW MTA WIN para Windows Posteriormente o programa SW MTW WIN é referido como software Todo o projecto programado é memorizado no terminal Change operation mode according to the following table ...

Страница 35: ... PC na programação do terminal Para instalar o software consultar o manual do produto The cmmunication parameters in the terminal and in the PC software should be set in the same way 1DPH 86 Cable 1 MTA PROG C Cable 2 MTA D25 C Cable 3 MTA MINI D25 Cable 4 100 240 VAC E900T E900VT E910T Cable 1 56 56 Personal computer ...

Страница 36: ...H 4Q 6pULH 6pULH H 1 A e QnA system 15m Cable 2 15m Cable 2 CR01 56 56 Note Not valid for the system AnE FX system 15m Cable 2 15m Cable 2 CR01 56 56 45 56 15m Cable 3 or Cable 2 Cable 4 15m Cable 3 CR01 or Cable 2 Cable 4 CR01 FX0 e FX2N system ...

Страница 37: ...P 4 6 LJDomR DR PyGXOR See Appendix A for settings on an C24 module 8 4 4 1 6 5 6 8 5 56 56 CH1 E C24 232 CAB See appendix D 56 56 CH2 E C24 422 CAB See appendix D 56 56 CH2 E C24 422 CAB See appendix D ...

Страница 38: ...P 4 7 6 5 6 8 5 6 4 5 6 4 56 56 Cable 1 56 56 56 56 CH1 Cable 1 CH2 E C24 422 CAB ...

Страница 39: ... com a configuração de caracter IBM Recorra ao manual da impressora para uma correcta configuração If you want to connect the terminal to a printer with a parallel interface you have to use the expan sion card IFC PI See the manual for IFC PI for further information 56 56 MAC PRINT CAB Printer ...

Страница 40: ...ilme com revestimento Autotex 2 F200 passível de ser impresso dos dois lados See SHQGL Material da parte traseira Placa de aço amarelo cromado Peso Excl D sub 3 5 kg 4 0 kg 3 3 kg Porta de série RS 422 Ficha fêmea 25 pin D sub com parafusos 4 40 UNC Porta de série RS 232 Ficha macho 9 pin D sub com parafusos 4 40 UNC Aberturas de expansão 2 1 2 Memória rápida for application 2 Mb Relógio de tempo ...

Страница 41: ...5000 h at the ambient temperature of 25 C Touch screen Tensão de alimentação 100 240 VAC Temperatura ambiente 0 to 50 C Temperatura de armazenamento 20 to 70 C Humidade relativa Máx 85 sem condensação Testes EMC ao terminal Teste de ruído de acordo com EN50081 2 emissão e EN50082 2 imunidade Este terminal está em conformidade com os requisitos essenciais do artigo quatro da directiva 89 336 EEC 3D...

Страница 42: ...LRQ RI 6HWWLQJ 6ZLWFK 1RWHV 21 2 SW11 ON Main channel settings RS 422 RS 232C Valid for modes A to D SW12 ON Data length 8 bits 7 bits SW13 OFF Transmission speed setting Refer to the table below SW14 ON SW15 ON SW16 OFF Parity check Enabled Disabled SW17 OFF Parity setting Even Odd Valid only when SW16 is ON SW18 OFF Stop bit 2 bits 1 bit SW21 ON Sum check Enabled Disabled For dedi cated protocol...

Страница 43: ...er minal resist ance Present Absent Valid only when SW11 is ON SW24 OFF Receive area terminal resist ance Present Absent 6ZLWFK HIDXOW FRPP VHWWLQJV LQ VRIWZDUH WR 6HWWLQJ LWHPV 3RVLWLRQ RI 6HWWLQJ 6ZLWFK 1RWHV 21 2 SW23 ON Computer link Multidrop Compu ter link Multidrop link Must be ON SW24 OFF Multi drop set tings Master station Local sta tion Valid only when SW23 is OFF DXGUDWH 8Q XVDEOH SW13 ...

Страница 44: ...p set tings Master station Local sta tion Valid only when SW2 is OFF SW02 Only R4 ON Computer link Multidrop Compu ter link Multidrop link Must be ON SW03 OFF Unused SW04 ON Write during RUN Enabled Disabled For dedi cated protocol SW05 OFF Transmission speed setting Refer to the table below SW06 ON SW07 ON SW08 ON Data length 8 bits 7 bits SW09 OFF Parity check Enabled Disabled SW10 OFF Parity se...

Страница 45: ...XVDEOH SW13 OFF ON OFF ON OFF ON OFF ON SW14 OFF OFF ON ON OFF OFF ON ON SW15 OFF OFF OFF OFF ON ON ON ON 6ZLWFK HIDXOW FRPP VHWWLQJV LQ VRIWZDUH WR 6HWWLQJ LWHPV 3RVLWLRQ RI 6HWWLQJ 6ZLWFK 1RWHV 21 2 SW01 OFF Operation set ting Interlock ing Independ ent CH1 always OFF SW02 ON Data length 8 bits 7 bits SW03 OFF Parity check Enabled Disabled SW04 OFF Parity setting Even Odd Valid only when SW03 is...

Страница 46: ...on the left side of the AJ71QC24 N DXGUDWH SW09 OFF ON OFF ON OFF ON OFF SW10 OFF OFF ON ON OFF OFF ON SW11 OFF OFF OFF OFF ON ON ON SW12 OFF OFF OFF OFF OFF OFF OFF DXGUDWH SW09 OFF ON OFF ON OFF ON SW10 OFF OFF ON ON OFF OFF SW11 OFF OFF OFF OFF ON ON SW12 OFF OFF OFF OFF OFF OFF DXGUDWH SW09 OFF ON OFF ON OFF ON SW10 ON ON OFF OFF ON ON 6ZLWFK HIDXOW FRPP VHWWLQJV LQ VRIWZDUH WR 6HWWLQJ LWHPV 3...

Страница 47: ...in 115200 BPS The settings of the switches must correspond with the communication settings in SW MTA WIN and in the terminal For more detailed information see the manual to the module SW11 ON ON OFF OFF OFF OFF SW12 OFF OFF ON ON ON ON DXGUDWH ...

Страница 48: ...mylacetate Glycerine White spirit Butycellosolve Methanol Fromic acid 50 Ether Triacetin Acetic acid 50 Sodium hypchlorite 20 Bleach Dowanol DRM PM Phosphoric acid 30 Hydrogen peroxide 25 Acetone Hydrochloric acid 36 Potassium carbonate Metyl ethyl ketone Nitric acid 10 Washing powders Dioxan Trichloracetic acid 50 Fabric conditioner Cyclohexanone Sulphuric acid 10 Ferric chloride MIBK Cutting oil...

Страница 49: ...visible staining Bichromate Turpentine substitute Potassium ferrocya nide ferricyanide Universal brake fluid Acetonitrile Decon Sodium bisulphate Aviation fuel Petrol Teepol Water Sea water Concentrated mineral acids Concentrated caustic solution High pressure steam at over 100 C Benzyl alcohol Mehylene chloride Top Job Grape Juice Ariel Ajax Jet Dry Milk Persil Vim Gumption Coffee Wisk Domestos F...

Страница 50: ...ed Autotex has been tested to 0 5 million switch operation at 40 C 40 F without loss of function 0D LPXP XVH WHPSHUDWXUH Low moderate humidity 85 C High humidity 90 RH 40 C 2XWGRRU XVH In common with all polyester based films Autotex is not suitable for use in conditions of long term exposure to direct sunlight Tomato juice Tomato ketchup Lemon juice Mustard ...

Страница 51: ...C 1 2XWOLQH ...

Страница 52: ...C 2 QVWDOODWLRQ ...

Страница 53: ...C 3 7H W VWULS ...

Страница 54: ...C 4 2XWOLQH ...

Страница 55: ...C 5 QVWDOODWLRQ ...

Страница 56: ...C 6 56 56 E900 E900 E900 E900 ...

Страница 57: ...D 1 DEOH GUDZLQJV E900 ...

Страница 58: ...D 2 Cable ...

Страница 59: ...D 3 E900 AJ71C24 AJ71UC24 ...

Страница 60: ...D 4 AJ71UC24 A1S J71UC24 R4 ...

Страница 61: ...D 5 E900 Cable Length ...

Страница 62: ...D 6 E900 QnA QnAS ...

Страница 63: ...D 7 E900 FX0S FX0N FX2N ...

Страница 64: ...D 8 E900 ...

Страница 65: ...D 9 E900 E900 E900 E900 E900 ...

Страница 66: ...D 10 E900 Cable Length ...

Отзывы: