Installation
Mitsubishi Electric, MA00776C
9
2
Installation
2.1 Space Requirements
– Installation plate thickness: 1.5 - 9.0 mm (0.06 - 0.35 inch)
– Space requirements when installing the operator panel:
Caution
The openings on the enclosure are for air convection. Do not cover these
openings.
2.2 Installation Process
1. Unpack and check the delivery. If damage is found, notify the supplier
.
Note:
Place the operator panel on a stable surface during installation.
Dropping it or letting it fall may cause damage.
2. Place the panel cut out where the operator panel is to be situated, draw along the
outer sides of the holes and cut according to the markings. If access to the text
strip is needed, add extra space in the lower left corner.
50 mm
50 mm
100 mm
285 mm
177 mm
56 mm
100 mm
100 mm
(6.97 inch)
(2.0 inch)
(4.0 inch)
(4.0 inch)
(2.0 inch)
(4.0 inch)
(2.20 inch)
(11.22 inch)
x 6
Panel cut out 245.5 x 138.5 mm
(9.67 x 5.45 inch)
5.0 mm
18.0 mm
For text strip
(0.20 inch)
(0.71 inch)
Содержание E1070
Страница 1: ...MITSUBISHI ELECTRIC E1070 Installation manual MA00776C 2008 07 English ...
Страница 4: ...Table of Contents Mitsubishi Electric MA00776C ...
Страница 8: ...Safety Precautions 8 Mitsubishi Electric MA00776C ...
Страница 12: ...Installation 12 Mitsubishi Electric MA00776C ...
Страница 14: ...Technical Data 14 Mitsubishi Electric MA00776C ...
Страница 18: ...Operator Panel Drawings 18 Mitsubishi Electric MA00776C 5 2 E1070 Outline Drawing No S 5031 Date 2004 10 14 ...
Страница 19: ...Operator Panel Drawings Mitsubishi Electric MA00776C 19 5 3 E1070 Text Strip Drawing No S 5027 Date 2004 08 12 ...
Страница 20: ...Operator Panel Drawings 20 Mitsubishi Electric MA00776C ...