OSD screen functions (continued)
CONFIGURATION2
CAT5 CONTROL
* Confi gurable only when the CAT5 Rx BOX (option) is
mounted on the option slot.
You can adjust the correction amount for the images
transmitted via CAT5 cable.
[CAT5 CABLE LENGTH]
Select the cable length, and the defaults of all the
adjustment values are automatically determined. After that,
you can set the adjustment items in detail according to the
type of the cable you use.
[CAT5 EQ.]
You can adjust the correction amount for the frequency
characteristics of the image signal.
Make adjustments so that blur and smear of the displayed
letters and graphic objects are minimized.
[CAT5 RED GAIN, GREEN GAIN, BLUE GAIN]
You can adjust the R, G, and B signal levels.
When the displayed image is dark, increase the R, G, and B
values equally. Adjusting GREEN GAIN fi rst makes it easy to
fi nd optimum levels.
When whites aren’t displayed as intended, adjust the
balance among R, G, and B. Adjusting RED GAIN and BLUE
GAIN with GREEN GAIN kept constant makes adjustment
easy.
NOTE: Before performing the color adjustment described
above, check the TINT settings on page 47.
[CAT5 RED SKEW, GREEN SKEW, BLUE SKEW]
Adjust each value so that the color deviation in the
displayed letters and graphic objects is minimized.
SERIAL CONTROL
* RS-485 can be set only when an optional CAT5 Rx BOX
is mounted on the option slot.
Select the communication interface (RS-232C, RS-485, or
LAN) for the serial communication function.
For connection of the signal cable, see page 23 to 29.
RS485 TERMINATION
* RS-485 can be set only when an optional CAT5 Rx BOX
is mounted on the option slot.
Turn ON or OFF the termination resistance of the RS-485
interface.
ON: Select this setting to use the monitor alone or to
confi gure the monitor as the one at the end of the
connection when more than one monitor is multi-
connected.
OFF: Select this setting to confi gure the monitor as other
than the one at the end of the connection when more
than one monitor is multi-connected.
LAN SETTING
You can set the communication parameters for the LAN
network.
DHCP CLIENT
Select whether to use DHCP client or not.
Select OFF when not using it, and select ON when using
it.
IP ADDRESS
When DHCP CLIENT is OFF, set the IP address of the
monitor.
When DHCP CLIENT is ON, you can check the value set
by the DHCP server.
SUBNET MASK
When DHCP CLIENT is OFF, set the gateway mask. Set it
to 255.255.255.0 for normal use.
When DHCP CLIENT is ON, you can check the value set
by the DHCP server.
DEFAULT GATEWAY
When DHCP CLIENT is OFF, set the IP address of the
gateway router to externally connect the local area
including the monitor.
When DHCP CLIENT is ON, you can check the value set
by the DHCP server.
PORT NUMBER
The port number (3007 and 63007) of the monitor is
displayed.
RESET
LAN settings are reset.
CONTROL TIME OUT
When using remote control, the timeout for transmission
intervals among codes within the control command can be
set.
10 ms: Set the time out intervals to 10 milliseconds.
2 s:
Set the time out intervals to 2 seconds.
30 s: Set the time out intervals to 30 seconds.