English-43
English
U-12
Remote control (continued)
Carry out as necessary
5) Read
command
The computer sends the command without datacode to the monitor.
After receiving this command, the monitor returns the command with datacode including the current status to the computer.
Example: When the computer asks the power status of the monitor, and the status of the monitor is powered-on.
Control command from computer
Return command from monitor to
computer
Description of command
30 30 76 50 0D ‘0’‘0’‘v’‘P’[enter]
Sending a command for checking the
power status
30 30 76 50 31 0D ‘0’‘0’‘v’‘P’‘1’[enter]
Monitor is powered-on.
Structure of the Read-command
ASCII
HEX
Function
Data (Receive)
Function
Data (Receive)
POWER
ON
vP
1
76 50
31
OFF (Sleep)
vP
0
76 50
30
Input
RGB-1 (HDMI)
vI
r1
76 49
72 31
RGB-2 (DVI-D)
vI
r2
76 49
72 32
RGB-3 (D-SUB)
vI
r3
76 49
72 33
RGB-4 (BNC)
vI
r4
76 49
72 34
OPTION*
vI
r5
76 49
72 35
RGB-6 (DISPLAY PORT)
vI
r6
76 49
72 36
Video
vI
v1
76 49
76 31
DVD/HD
vI
v2
76 49
76 32
S-VIDEO
vI
v3
76 49
76 33
Internal
temperature
Around the main
board
Resolution
1˚C
tc1
(ex.) +25
74 63 31
2B 20 32 35
Around the power
supply
Resolution
1˚C
tc2
(ex.) +31
74 63 32
2B 20 33 31
*
OPTION can be used when an extension module is mounted on the option slot.
NOTE:
The monitor will acknowledge the power-on/off command issued from the OPS-compliant computer, however, it will not execute
the command. This is not a malfunction. For automatic operation, use SCHEDULE in the CONFIGURATION2 menu of the OSD
screen function.
LAN Remote control
When you connect the monitor and the computer using network devices such as LAN hub and LAN cable (see page 28) and then
confi gure the network settings using the OSD screen function in advance, you can remote-control the monitor using the same
commands as those for RS-232C.
1. Setting
procedure
(1) Set the following network parameters using the OSD menu. (See page 53.)
• DHCP client ON/OFF, IP address, subnet mask and default gateway
(2) Set the IP address described above and the port number (63007 or 3007) using the application program of your computer to
perform the socket communication.
(3) Send the same control command as that for RS-232C or RS-485 via TCP/IP socket communication.
(4) Check the return command sent from the monitor. When it is received successfully, the setting is completed.
CAUTION:
Do not connect the CAT5 IN or the CAT5 OUT connector to the LAN connector. If connected, both of the connectors may fail.