WIRING DIAGRAM
6
PLFY-P20VEM-E.UK PLFY-P25VEM-E.UK PLFY-P32VEM-E.UK
PLFY-P40VEM-E.UK
PLFY-P50VEM-E.UK
PLFY-P63VEM-E.UK PLFY-P80VEM-E.UK
PLFY-P100VEM-E.UK
PLFY-P125VEM-E.UK
CN27
CN32
CN51
CN52
SW2
SW3
F1
MF
MV
DP
FS
TB2
TB5
TB15
LEV
W.B
RU
BZ
LED1
LED2
SW1
SW2
POWER SUPPLY
TRANSMISSION
MA-REMOTE CONTROLLER
FAN MOTOR
VANE MOTOR
MT
I-SEE SENSOR MOTOR
DRAIN PUMP
DRAIN FLOAT SWITCH
TERMINAL
BLOCK
LINEAR EXPANSION VALVE
I. B
INDOOR CONTROLLER BOARD
CONNECTOR DAMPER
REMOTE SWITCH
CENTRALLY CONTROL
REMOTE INDICATION
CAPACITY CODE
SW1
MODE SELECTION
MODE SELECTION
SW11
ADDRESS SETTING 1s DIGIT
SW12
ADDRESS SETTING 10s DIGIT
SW14
BRANCH NO.
SW21
CEILING HEIGHT
DISCHARGE OUTLET NUMBER
OPTION SELECTOR
SW22
SWE
DRAIN PUMP (TEST MODE)
PAIR NO. SETTING
SWITCH
FUSE (T 6.3AL 250V)
SYMBOL
OPTION PART
PCB FOR WIRELESS REMOTE CONTROLLER
RECEIVING UNIT
BUZZER
LED (OPERATION INDICATION : GREEN)
LED (PREPARATION FOR HEATING : ORANGE)
EMERGENCY OPERATION (HEAT / DOWN)
EMERGENCY OPERATION (COOL / UP)
SYMBOL
NAME
NAME
TH21
TH22
TH23
ROOM TEMP. DETECTION
(0ºC/15k
Ω
, 25ºC/5.4k
Ω)
PIPE TEMP. DETECTION / LIQUID
(0ºC/15k
Ω
, 25ºC/5.4k
Ω)
PIPE TEMP. DETECTION / GAS
(0ºC/15k
Ω
, 25ºC/5.4k
Ω)
THERMISTOR
1
19
20
20
2
CNV
(WH)
CN20
(RD)
I-SEE
SENSOR
CN44
(WH)
5
5
5
5
MV
I-SEE SENSOR
CORNER PANEL
(OPTION PART)
MV
MV
MV
M
M
M
M
LEV
M
MT
M
LED1
LED2
1
1
3
7
4
1
DP
3~
MF
CNP
(WH)
MS
1
2
3~
MS
CN5Y
(WH)
W.B
I.B
RU
LED2 LED1
SW2
SW1
CNB
9
6
9
BZ
5
3
1
1
4
CND
(BK)
BK
RD
CNMF
(WH)
1
4
1
4
1
6
1
9
CN51
(WH)
CN52
(GN)
S
M2
M1
2
1
TB5
TB15
10s DIGIT
1s DIGIT
SW1
SW12
SW11
SW14
0 9 8 7 6 5 4 3 2 1
SW3
0 9 8 7 6 5 4 3 2 1
SW2
6 5 4 3 2 1
SW21
6 5 4 3 2 1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
SW22
4 3 2 1
0123
45
678
9A
B
C
D
EF
0 1
2
3
45
6
7
8
9
0 1
2
3
45
6
7
8
9
3
1
CN90
(WH)
CN4F
(WH)
CN4Z
(WH)
CN32
(WH)
1
5
1
5
1
5
SWE
ON
OFF
tº
TH21
FS
tº
TH23
tº
TH22
CN60
(WH)
BU
F1
+
-
Refer to table 1.
TO NEXT
INDOOR UNIT
PULL
BOX
FUSE(16A)
BREAKER
(16A)
L
N
1
2
CN27
(RD)
TO OUTDOOR UNIT BC CONTROLLER
ME-REMOTE CONTROLLER
24-30V DC
TO MA-REMOTE CONTROLLER 8.7-13V DC
POWER SUPPLY
~/N 220-240V 50Hz
220V 60Hz
* Be sure to turn off the source power and
then disconnect fan motor connector.
(Failure to do so will cause trouble in
Fan motor)
BRANCH No.
4
1
4
1
CN4G
AUTOMATIC FILTER
ELEVATION PANEL
(OPTION PART)
CN4G
(BU)
4
5
4
NOTES:
1. At servicing for outdoor unit, always follow the wiring
diagram of outdoor unit.
2. In case of using MA-Remote controller, please connect
to TB15. (Remote controller wire is non-polar.)
3. In case of using ME-Remote controller, please connect
to TB5. (Transmission line is non-polar.)
4. Symbol [S]of TB5 is the shield wire connection.
5. Symbols used in wiring diagram above are,
: terminal block, : connector.
6. The setting of SW2 differs in the capacity and model.
For the detail, refer to the table 1.
7. Make sure to turn off the indoor and the outdoor units
before replacing indoor controller board.
8. is the switch position.
Mark
LED1
Main power supply
Power supply for
MA-Remote controller
Main Power supply (Indoor unit:220-240V AC)
power on → lamp is lit
Power supply for MA-Remote controller
on → lamp is lit
LED2
Meaning
Function
LED on indoor board for service
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
25
MODELS
MODELS
SW2
SW2
32
40
50
63
ON
OFF
1 2 3 4 5 6
20
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
MODELS
SW2
80
100
ON
OFF
1 2 3 4 5 6
125
<Table 1> SW2 (CAPACITY CODE)
OCH657