15
GB
H
A
D
J
A
Main unit
B
Corner of drain pipe
C
Claw on the main unit
D
Grille
1
E
Hole on the grille
F
Hook for temporary installation
G
Screw with captive washer
H
Ceiling surface
J
No gap
K
$GMXVWWKHQXWRIPDLQXQLWXVLQJDZUHQFK
etc.
)LJ
)LJ
)LJ
)LJ
)LJ
)LJ
F
E
D
A
B
C
C
D
G
K
C
B
A
D
H
E
C
B
G
F
D
A
G
C
F
E
B
A
A
Clamp of the main unit
B
Electrical box
C
Lead wires of the grille
D
CNV connector on the controller board
A
CN4Z on the controller board
B
CN5Y on the controller board
C
Lead wire of i-see Sensor corner panel
D
Clamp
E
Hole of grille (Pass the lead wire.)
F
Screw
3
G
i-see Sensor corner panel
4
< The grille temporary installed >
7HPSRUDU\LQVWDOODWLRQRIWKHJULOOH)LJ
-RLQWKHFRUQHURIGUDLQSLSHRQWKHPDLQXQLWZLWKWKHFRUQHUZLWKKROHRQWKHJULOOH
and put them together temporarily by hanging the hook of the grille to the claw of
the main unit.
)L[LQJWKHJULOOH
%\WLJKWHQLQJWKHSUHLQVWDOOHGVFUHZV¿[WKHJULOOHRQWRWKHPDLQXQLW)LJ
Note:
Make sure there is no gap between the main unit and the grille or between the
grille and the ceiling surface. (Fig. 6-6)
If there is a gap between the grille and the ceiling:
:LWKWKHJULOOHDWWDFKHGVOLJKWO\DGMXVWWKHLQVWDOODWLRQKHLJKWRIWKHPDLQXQLWDQG
clear the gap.
Caution:
:KHQWLJKWHQLQJWKHVFUHZPDNHVXUHWKDWWKHWLJKWHQLQJWRUTXHLV1P
WR1P1HYHUXVHDQLPSDFWVFUHZGULYHU
$IWHUWLJKWHQLQJWKHVFUHZFRQ¿UPWKDWWKHWZRJULOOHKRRNV)LJDUH
ODWFKHGRQWRWKHKRRNVRQWKHPDLQXQLW
:LUHFRQQHFWLRQ)LJ
/RRVHWKHVFUHZV¿[LQJWKHHOHFWULFDOER[FRYHURQWKHPDLQXQLWDQGVOLGHWKH
cover to open.
5RXWHWKHOHDGZLUHIURPVLGHRIWKHHOHFWULFDOER[
0DNHVXUHWRFRQQHFWDFRQQHFWRUIRUYDQHPRWRUZKLWHSROHVWR&19FRQ
-
nector (white) on the controller board of the main unit.
/HDGZLUHVWKDWOHDGRIIWKHJULOOHPXVWEHKHOGWRJHWKHUZLWKRXWVODFNXVLQJDFODPS
into the electrical box.
,QVWDOOLQJVLJQDOUHFHLYHU)LJ
Route the lead wire (white, 9 poles) for signal receiver corner panel from the side
of the electrical box on the main unit.
0DNHVXUHWRFRQQHFWWR&1ZKLWHRQWKHFRQWUROOHUERDUG
0DNHVXUHWKDWWKHOHDGZLUHRIWKHVLJQDOUHFHLYHUFRUQHUSDQHOLVSDVVHGWKURXJK
the claw of bellmouth.
7KHUHPDLQLQJOHDGZLUHPXVWEHKHOGWRJHWKHUZLWKRXWVODFNXVLQJDFODPSLQWR
the electrical box.
3XWWKHFRYHUEDFNRQWKHHOHFWULFDOER[ZLWKVFUHZV
Note:
Make sure wires are not caught in the electrical box cover.
,QVWDOOWKHVLJQDOUHFHLYHUFRUQHUSDQHOWRWKHSDQHODQG¿[ZLWKWKHVFUHZ
The signal receiver corner panel can not be installed on the drain pipe side for the
main unit. (Refer to Fig. 6-11)
A
Signal receiver corner panel
B
Hole of grille (Pass the lead wire.)
C
Claw of bell mouth
D
Wire
E
Clamp
F
Cable band (Secure the lead wire.)
G
CN90 on controller board
H
Screw
,QVWDOODWLRQRILVHH6HQVRUFRUQHUSDQHO)LJ
5RXWHWKHOHDGZLUHIURPWKHVLGHRIHOHFWULFDOER[
5RXWHWKHOHDGZLUHFRQQHFWRUZKLWHSROHVDQGZKLWHSROHVRIWKHLVHH6HQ
-
sor corner panel
4
from the side of the electrical box on the main unit and connect
to the connector CN4Z and CN5Y on the controller board.
7KHUHPDLQLQJOHDGZLUHRILVHH6HQVRUFRUQHUSDQHOPXVWEHKHOGWRJHWKHUZLWKRXW
slack using the clamp into the electrical box.
3XWWKHFRYHUEDFNRQWKHHOHFWULFDOER[ZLWKVFUHZV
Note:
Make sure wires are not caught in the electrical box cover.
7KHLVHH6HQVRUFRUQHUSDQHOVKRXOGEH¿[HGRQWRWKHJULOOH
1
with screw
3
.
* If the position of the i-see Sensor was changed from default position (position
3
)
to the other position, change the function settings. (Fig. 6-11)
7KHLVHH6HQVRUFRUQHUSDQHOFDQQRWLQVWDOOHGRQWKHGUDLQSLSHVLGHIRUWKHPDLQ
unit. (Refer to Fig. 6-11)
Position
1
'HIDXOWVLJQDOUHFHLYHUSRVLWLRQ$LURXWOHWLGHQWL¿FDWLRQPDUNVƑƑƑƑƑ
Position
2
$LURXWOHWLGHQWL¿FDWLRQPDUNVƑƑƑ
Position
3
'HIDXOWLVHH6HQVRUSRVLWLRQ$LURXWOHWLGHQWL¿FDWLRQPDUNVƑƑƑƑƑ
Position
1
Position
2
Position
3
Refrigerant pipe
Prohibited installation
position
Drain pipe
,QVWDOOLQJWKHJULOOH