11
2SHUDWLRQ)RU:LUHG5HPRWHFRQWUROOHU
3.6. 3D i-see Sensor setting
3.6.1 3D i-see Sensor setting
Main
Main menu
Operation
MENU
ON
OFF
RETURN SELECT
HOLD
Main menu: RETURN
Cursor
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
MENU
ON
OFF
RETURN SELECT
HOLD
Setting display: SELECT
Cursor
Comfort
Manual vane angle
3D i-See sensor
MENU
ON
OFF
RETURN SELECT
HOLD
MENU
ON
OFF
RETURN SELECT
HOLD
Setting display: SELECT
Cursor
3D i-See sensor
Air distribution
Energy saving option
Seasonal airflow
2
Select “Comfort” from the
Operation menu, and press the
[SELECT/HOLD] button.
3
Select “3D i-See sensor” with the
[F1] or [F2] button, and press the
[SELECT/HOLD] button.
4
Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT/HOLD] button.
• Air distribution
6HOHFWWKHDLUÀRZGLUHFWLRQFRQWURO
PHWKRGZKHQWKHDLUÀRZGLUHFWLRQ
is set to “Auto”.
• Energy saving option
Operates the energy-save mode
according to whether persons are
detected in the room by the 3D
i-see Sensor.
6HDVRQDODLUÀRZ
When the thermostat turns off, the
fan and the vanes operate accord-
ing to the control settings.
1
Select the M-NET address for the
units to whose vanes are to be
¿[HGZLWKWKH>)@RU>)@EXWWRQ
and press the [SELECT/HOLD]
button.
3UHVVWKH>)@EXWWRQWRFRQ¿UPWKH
unit.
The vane of only the target indoor
unit is pointing downward.
2
Select the menu with the [F4] but-
ton.
'HIDXOWĺ$UHDĺ'LUHFW,QGLUHFW
ĺ'HIDXOW«
Default: The vanes move the same
as during normal operation.
During cooling mode, all of the
vanes move to the horizontal air-
ÀRZGLUHFWLRQ
During heating mode, all of the
YDQHV PRYH WR WKH GRZQ DLUÀRZ
direction.
Area: The vanes move to the down
DLUÀRZGLUHFWLRQWRZDUGDUHDVZLWK
a high floor temperature during
cooling mode and toward areas
ZLWKDORZÀRRUWHPSHUDWXUHGXU
-
ing heating mode. Otherwise,
the vanes move to the horizontal
DLUÀRZGLUHFWLRQ
Direct/Indirect: The vanes auto-
matically move relative to the areas
where persons are detected.
The vanes operate as indicated in
the following table.
3
When Direct/Indirect is selected,
set each air outlet.
Select the air outlet with the [F1] or
[F2] button, and change the setting
with the [F4] button.
After changing the settings for all of
the air outlets, press the [SELECT/
HOLD] button to save the settings.
* In order to enable this function,
WKH DLUÀRZ GLUHFWLRQ PXVW EH VHW
to “Auto”.
3.6.2 Air
distribution
Air distribution
Input display: SELECT
Address
Check
M-NET address
Identify unit Check button
MENU
ON
OFF
RETURN SELECT
HOLD
Air distribution
Select: SELECT
Cur.
M-NET address
Auto vane
Direct/Indirect setting
Direct/Indirect
MENU
ON
OFF
RETURN SELECT
HOLD
Vane setting
Direct
Indirect
Cooling
KRUL]RQWDOĺVZLQJ
keep horizontal
Heating
keep downward
GRZQZDUGĺKRUL]RQWDO
MENU
ON
OFF
RETURN SELECT
HOLD
Direct/Indirect setting
:
Direct
: Indirect
: Indirect
: Direct
Select: SELECT
Outlet
Angle
1
Select “Operation” from the Main
menu, and press the [SELECT/
HOLD] button.