8
GB
2.3.2. Installing the refrigerant piping
Check the Connection Kit accessories and parts
1
Pipe cover × 2
2
Thermistor holder - ø9.52 × 1
3
Thermistor holder - ø12.7 × 1
Connect Connection Kit to the liquid pipe.
When brazing the refrigerant pipes, be sure to braze, after covering a wet cloth to the insulation pipes of the units in order to prevent
it from burning and shrinking by heat.
Press the pipe cover
1
on the liquid piping against the Connection Kit and wrap it to hold it in place.
Fasten the supplied bands 20 mm from each of the pipe covers
1
.
Wrap the pipe cover
1
with tape.
Connection kit
Refrigerant pipe (procure locally)
Brazing
To indoor unit
To outdoor unit
(120)
20
20
Connection kit
Band (procure locally)
Refrigerant pipe
(procure locally)
1
Pipe cover
Tape (procure locally)