GB
. Operation
Notes:
Any person at the following places cannot be detected.
Ɣ
Along the wall on which the air conditioner is installed
Ɣ
Directly under the air conditioner
Ɣ
:
here any obstacle, such as furniture, is between the person and
the air conditioner
A person may not be detected in the following situations.
Ɣ
Room temperature is high.
Ɣ
A person wears heavy clothes and his/her skin is not exposed.
Ɣ
A heating element of which temperature changes signi
¿
cantly is
present.
Ɣ
Some heat sources, such as a small child or pet, may not be sensed.
Ɣ
A heat source does not move for a long time.
The
D i-See sensor operates once approximately every
minutes
to measure the floor temperature and detect persons in the room.
Ɣ
The intermittent operating sound is a normal sound produced when
the
D i-See sensor is moving.
Ɣ
:
hen 1 MA Remote Controller is used to control multiple indoor
units, No occupancy Auto-OFF cannot be used.
.6.4 Seasonal airflow function
F1
F2
F3
F4
Seasonal airflow
Select:
Seasonal airflow
Cooling/Heating
1
Select the setting with the [F4]
button.
2)) ĺ &RROLQJ RQO\ ĺ +HDWLQJ
RQO\ĺ&HDWLQJĺ2))«
After changing the setting, press
the [SELECT] button to save the
setting.
OFF: The function is disabled.
Cooling only: When the thermostat
turns off during cooling mode, the
vanes move up and down.
Heating only: When the thermostat
turns off during heating mode,
the vanes move to the horizontal
airflow direction to circulate the air.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
* In order to enable this function,
the airflow direction must be set
to “Auto”.
Notes:
Ɣ
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Ɣ
Available directions depend on the type of unit connected.
Ɣ
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1.
:
hile the display is in “STAND BY” or “DEFROST” states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
. In heat mode, when room temperature is higher than the tem-
perature setting.
.7. Ventilation
For LOSSNAY combination
Ŷ
The following 2 patterns of operation is available.
5XQWKHYHQWLODWRUWRJHWKHUZLWKLQGRRUXQLW
5XQWKHYHQWLODWRULQGHSHQGHQWO\
Notes: (for wireless remote controller)
Ɣ
Running the ventilator independently is not available.
Ɣ
No indication on the remote controller.
4. Timer
Ŷ
Timer functions are different by each remote controller.
Ŷ
For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller.