• For your safety, thoroughly read the following instructions prior to installation.

Safety Precautions

• Thoroughly read the following “Safety Precautions” to ensure proper installation.
• Observe the following important safety precautions at all times.
• Hazards that can occur from incorrect handling are classified by the symbols below:

WARNING
CAUTION

Incorrect handling can result in death or serious injury.

Incorrect handling can result in bodily injury and/or structure damage.

 

WARNING

Only a dealer or qualified technician should 

perform installation.

Properly install all parts according to the 

instructions in the Installation Manual.

After installation, check for a refrigerant leak.

Do not make any modifications or alterations.

Consult your dealer for repair.

When installing or relocating the unit, check that 

no substance other than the specified refrigerant 

(R410A) enters the refrigerant circuit.

In the event of a refrigerant leak, thoroughly 

ventilate the room.

• Improper installation may result in refrigerant gas leakage and 

equipment damage.

• If the wrong twinning pipe or wrong size connecting pipe is used, 

air conditioning performance will suffer.

• If leaked refrigerant comes in contact with a heat source, such 

as a fan heater, stove, or electric grill, toxic gases will be  

generated.

• Improper installation may result in water leakage, electric shock, 

or fire.

• Any presence of foreign substance or air can cause abnormal 

pressure rise or explosion.

• If refrigerant leaks and comes in contact with an open flame, 

toxic gases will be generated.

CAUTION

Do not touch the refrigerant pipes and refrigerant 

circuit components with bare hands during and 

immediately after operation.

• During or immediately after operation, certain parts of the unit 

such as pipes and compressor may be either very cold or hot, 

depending on the state of the refrigerant in the unit at the time. 

To reduce the risk of frostbites and burns, do not touch these 

parts with bare hands.

Properly dispose of packing materials.

• Plastic bags can pose suffocation and choking hazards: keep 

them out of the reach of children. Tear the plastics bags before 

disposing of them.

 

* See the Installation Manual that came with the outdoor unit for installation instructions.

WT09183X01

Mitsubishi Electric Air Conditioner CITY MULTI

 

CMY-R100NCBK, CMY-R200NCBK, CMY-R300NCBK

 

Twinning Kit Installation Manual

Содержание CITY MULTI CMY-R100NCBK

Страница 1: ...r wrong size connecting pipe is used air conditioning performance will suffer If leaked refrigerant comes in contact with a heat source such as a fan heater stove or electric grill toxic gases will be generated Improper installation may result in water leakage electric shock or fire Any presence of foreign substance or air can cause abnormal pressure rise or explosion If refrigerant leaks and come...

Страница 2: ...0NCBK High pressure Low pressure OD22 2 7 8 ID28 58 1 1 8 2 OD28 58 1 1 8 ID34 93 1 3 8 CMY R300NCBK High pressure OD19 05 3 4 ID22 2 7 8 2 Low pressure OD34 93 1 3 8 ID41 28 1 5 8 3 List of field supplied parts Refrigerant pipes other than the ones provided in the kit Heat resistant insulation material for field supplied refrigerant pipes Insulation cover tape 2 Selecting the Correct Size Refrige...

Страница 3: ...tion The section of the field supplied pipe that connects to the twinning pipe must have at least 500 mm 19 11 16 in of straight section If the straight section is less than 500 mm 19 11 16 in it may result in equipment damage 4 Pipe connection Make sure the pipes from the twinning pipe to the outdoor unit are sloped downwards A B If twinning pipe is installed above the base of the outdoor unit it...

Страница 4: ...inning kit Insulation cover Tape field supply Tape field supply 5 Miscellaneous Notes Secure the field supplied pipes with a pipe cover and a cable tie in place to keep them from coming in contact with other pipes as necessary The pipe section before the twinning pipe must have at least 500 mm 19 11 16 in of straight section Twinning kit On site piping On site piping Tape field supplied To be gap ...

Отзывы: