9

en

Do not reconstruct or change the settings of the protection devices.

- If the pressure switch, thermal switch, or other protection device is shorted or

operated forcibly, or parts other than those specified by Mitsubishi Electric are
used, fire or explosion may result.

To dispose of this product, consult your dealer.

The installer and system specialist shall secure safety against leakage
according to local regulation or standards.

- Choose the appropriate wire size and the switch capacities for the main power

supply described in this manual if local regulations are not available.

Pay special attention to the place of installation, such as basement, etc.
where refrigeration gas can accumulate, since refrigerant is heavier than
the air.

This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the
appliance.

This appliance is intended to be used by expert or trained users in shops,
in light industry and on farms, or for commercial use by lay persons.

Do not repetitively turn on and off the unit in a short period.

Wait until the power-supply voltage and the power-supply frequency
stabilize before turning on the power supply.

1.2.  Precautions for devices that use R32 

refrigerant

Caution:

Do not use existing refrigerant piping.

- The old refrigerant and refrigerant oil in the existing piping contain a large

amount of chlorine which may cause the refrigerant oil of the new unit to
deteriorate.

- R32 is high-pressure refrigerant and can cause the existing piping to burst.

Use refrigerant piping made of phosphorus deoxidized copper and copper
alloy seamless pipes and tubes. In addition, be sure that the inner and
outer surfaces of the pipes are clean and free of hazardous sulphur,
oxides, dust/dirt, shaving particles, oils, moisture, or any other
contaminant.

- Contaminants on the inside of the refrigerant piping may cause the refrigerant

residual oil to deteriorate.

Store the piping to be used during installation indoors and keep both ends
of the piping sealed until just before brazing. (Store elbows and other joints
in a plastic bag.)

- If dust, dirt, or water enters the refrigerant cycle, deterioration of the oil and

compressor failure may result.

Apply a small amount of ester oil, ether oil, or alkyl benzene to flares. (for
indoor unit)

- Infiltration of a large amount of mineral oil may cause the refrigerant oil to

deteriorate.

Do not use a refrigerant other than R32.

- If another refrigerant (R22, etc.) is mixed with R32, the chlorine in the

refrigerant may cause the refrigerant oil to deteriorate.

Use a vacuum pump with a reverse flow check valve.

- The vacuum pump oil may flow back into the refrigerant cycle and cause the

refrigerant oil to deteriorate.

Do not use the following tools that are used with conventional refrigerants.
(Gauge manifold, charge hose, gas leak detector, reverse flow check valve,
refrigerant charge base, refrigerant recovery equipment)

- If the conventional refrigerant and refrigerant oil are mixed in the R32, the

refrigerant may deteriorate.

- If water is mixed in the R32, the refrigerant oil may deteriorate.
- Since R32 does not contain any chlorine, gas leak detectors for conventional

refrigerants will not react to it.

Refrigerant R32 is flammable. Do not use a naked-flame type detector.

Carry a refrigerant leak detection sensor when installing or removing the
unit.

Do not use a charging cylinder.

- Using a charging cylinder may cause the refrigerant to deteriorate.

Do not use antioxidant or leak-detection additive.

Be especially careful when managing the tools.

- If dust, dirt, or water gets into the refrigerant cycle, the refrigerant may

deteriorate.

1.3. Before installation

Caution:

Do not install the unit where combustible gas may leak.

- If the gas leaks and accumulates around the unit, an explosion may result.

Do not use the air conditioner where food, pets, plants, precision
instruments, or artwork are kept.

- The quality of the food, etc. may deteriorate.

Do not use the air conditioner in special environments.

- Oil, steam, sulfuric smoke, etc. can significantly reduce the performance of the

air conditioner or damage its parts.

When installing the unit in a hospital, communication station, or similar
place, provide sufficient protection against noise.

- Sound pressure level does not exceed 70 dB(A). However, inverter equipment,

private power generator, high-frequency medical equipment, or radio
communication equipment may cause the air conditioner to operate
erroneously, or fail to operate. On the other hand, the air conditioner may affect
such equipment by creating noise that disturbs medical treatment or image
broadcasting.

Do not install the unit on or over things that are subject to water damage.

- When the room humidity exceeds 80% or when the drain pipe is clogged,

condensation may drip from the indoor unit or hydro unit. Perform collective
drainage work together with the outdoor unit, as required.

Do not install the unit where corrosive gas may be generated.

- Doing so can corrode the pipes, resulting in refrigerant leakage and fire.

Check that markings of the unit are not illegible.

- Illegible warning or caution markings may cause damage to the unit, resulting

in injury.

1.4.  Before installation (relocation) - 

electrical work

Caution:

Ground the unit.

- Do not connect the ground wire to gas or water pipes, lightning rods, or

telephone ground lines. Improper grounding may result in electric shock.

Install the power cable so that tension is not applied to the cable.

- Tension may cause the cable to break and generate heat and cause a fire.

Install a leak circuit breaker, as required.

- If a leak circuit breaker is not installed, electric shock may result.

Use power line cables of sufficient current carrying capacity and rating.

- Cables that are too small may leak, generate heat, and cause a fire.

Use only a circuit breaker and fuse of the specified capacity.

- A fuse or circuit breaker of a larger capacity, or the use of substitute simple

steel or copper wire may result in a general unit failure or fire.

Do not wash the air conditioner units.

- Washing them may cause an electric shock.

Be careful that the installation base is not damaged by long use.

- If the damage is left uncorrected, the unit may fall and cause personal injury or

property damage.

Install the drain piping according to this Installation Manual to ensure
proper drainage. Wrap thermal insulation around the pipes to prevent
condensation.

- Improper drain piping may cause water leakage causing damage to furniture

and other possessions.

Be very careful about transporting the product.

- One person should not carry the product. Its weight is in excess of 20 kg.
- Some products use PP bands for packaging. Do not use any PP bands as a

means of transportation. It is dangerous.

Safely dispose of the packing materials.

- Packing materials, such as nails and other metal or wooden parts, may cause

stabs or other injuries.

- Tear apart and throw away plastic packaging bags so that children will not play

with them. If children play with a plastic bag which has not been torn apart, they
face the risk of suffocation.

When air flow decrease is detected of a circulation fan beside the hydro
unit installed at the height of less than 1.8 m from the ground, the system
must be powered off within 10 seconds from the detection. Before
powering off the system, connect the contactor to the power cable of the
outdoor unit and open the contactor. For the connection procedures,
specifications, and installation location of the contactor, refer to the
manual of the outdoor unit.

1.5.  Before starting the test run

Caution:

Turn on the power at least 12 hours before starting operation.

- Starting operation immediately after turning on the main power switch can

result in irreversible damage to internal parts. Keep the power switch turned on
during the operational season.

Do not touch the switches with wet fingers.

- Touching a switch with wet fingers can result in an electric shock.

Do not touch the refrigerant pipes during and immediately after operation.

- During and immediately after operation, the refrigerant pipes may be hot or

cold, depending on the condition of the refrigerant flowing through the
refrigerant piping, compressor, and other refrigerant cycle parts. Your hands
may suffer burns or frostbite if you touch the refrigerant pipes.

Do not operate the air conditioner with the panels and guards removed.

- Rotating, hot, or high-voltage parts can cause injuries.

Do not turn off the power immediately after stopping operation.

- Always wait at least 5 minutes before turning off the power. Otherwise,

drainage water leakage or mechanical failure of sensitive parts may occur.

Check for refrigerant leaks before service. 

- If the refrigerant leaks, fire may result.

WT09052X01_en.book  9 ページ  2019年1月17日 木曜日 午前10時49分

Содержание City Multi CMH-WM250V-A

Страница 1: ... εγχειρίδιο εγκατάστασης πριν αρχίσετε την εγκατάσταση της μονάδας κλιματισμού tr MONTAJ ELKİTABI Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını monte etmeden önce bu elkitabını dikkatle okuyunuz 中 简 安装手册 为了安全和正确地使用本空调器 请在安装前仔细阅读本安装手册 sk NÁVOD NA INŠTALÁCIU Pre bezpečné a správne použitie si pred inštalovaním klimatizačnej jednotky prosím starostlivo prečítajt...

Страница 2: ...mation contact your local distributor Item Piping in the figure Max length Max equivalent length Total piping length A A B C D E a b c d e f g 1000 Farthest indoor unit from outdoor unit L1 A A C D E g A B c 165 190 Between outdoor unit and hydro unit refrigerant pipework A 110 Farthest indoor unit from hydro unit L3 A C D E g A B c 60 60 Height between outdoor unit and indoor unit outdoor unit ab...

Страница 3: ...Connecting pipe diameter of hydro unit If the connecting pipe diameter of hydro unit differs from that of outdoor unit expand or reduce the pipe diameter at the inlet of the hydro unit Hydro unit Unit model Model name Outdoor unit side PUHY M200 CMH WM250V A PUHY M250 1 2 PUHY M300 3 CMH WM350V A 4 PUHY M350 PUHY M400 5 CMH WM500V A PUHY M450 PUHY M500 Hydro unit Unit model Model name Outdoor unit...

Страница 4: ...r covering B If a polyethylene cover is used as an outer covering asphalt roofing is not necessary Insulation material A Glass fiber Steel wire Adhesive Heat resistant polyethylene foam Adhesive tape Outer covering B Indoor Vinyl tape Under the floor and exposed Waterproof hemp cloth Bronze asphalt Outdoor Waterproof hemp cloth Zinc plate Oily paint A Downward slope 1 100 or more B Drain hose C Un...

Страница 5: ...ire C Blown asphalt D Base paper E Pipe F Glass wool Note Absorbent material G Asphalt felt H Cotton tape After wrapping it around a pipe brush polyester synthetic resin over the tape Fig 5 2 1 A B C D E Fig 5 2 2 A Adhesive Completely fill joints of foam polystyrene pipe insulation and a gap between a pipe and foam polystyrene pipe insulation with adhesive B Pipe C Form polystyrene pipe insulatio...

Страница 6: ...ter pipe supply pipe B Bind here using band or tape C Galvanized steel sheet cover D Soldering E Caulking waterproof material elastomeric sealant F Mortal waterproofing membrane G Concrete 150 mm A B C D C A D A Sleeve B No thermal insulation C Thermal insulation materials D Pipe Fig 5 2 5 Thermal and cold insulation work on a pipe penetrating through a beam 250 mm A B C D E Fig 5 2 6 A Pipe B Hea...

Страница 7: ... B D E C A Control box B Power source wiring C ø32 hole closed rubber bushing D Transmission wiring E Clip cables here Fig 6 0 1 CMH WM250V A CMH WM350V A CMH WM500V A WT09052X01_en book 7 ページ 2019年1月17日 木曜日 午前10時49分 ...

Страница 8: ...y this company may lead to damage fire explosions etc Do not spray water on electrical parts This could lead to shorting fire smoke electrical shock unit failure etc Do not create a situation where the refrigeration circuit is sealed yet incomplete with oil or refrigerant in the system This may result in an explosion Do not touch electrical components during or directly after operation This may le...

Страница 9: ...ital communication station or similar place provide sufficient protection against noise Sound pressure level does not exceed 70 dB A However inverter equipment private power generator high frequency medical equipment or radio communication equipment may cause the air conditioner to operate erroneously or fail to operate On the other hand the air conditioner may affect such equipment by creating no...

Страница 10: ...ater provide sufficient space for maintenance accordingly For details refer to the Data Book or installation manual for the panel heater Warning Be sure to install the unit in a place that can sustain the entire weight If there is a lack of strength it may cause the unit to fall down resulting in an injury Caution Be sure to install the unit horizontally Install the hydro unit level less than 1 ti...

Страница 11: ...ng Fig 4 1 1 P 3 Note Be sure to use non oxidative brazing Refrigerant piping connection examples Obtain joints and elbows on site as necessary according to the pipe diameter and connect the pipes as shown in the figures below Fig 4 1 2 P 4 1 When routing the pipes through the front of the unit 2 When routing the pipes through the bottom of the unit 3 Pipe connection port and connecting pipe Model...

Страница 12: ...hen certain specifications presented by the client must be met ensure that they also meet the specifications on the chart above The brazed connections must be covered with insulation with its seam facing upward and fastened with the bands 4 4 Drain piping work Drain or condensation water will be discharged from hydro units during test run If this will be a problem install a separately sold drain p...

Страница 13: ...plied strainer in the inlet pipe on the unit to keep foreign objects e g bolts and stones out of the water side heat exchanger Route the piping so that the pipes will not interfere with replacement of internal components e g pumps of the unit 5 2 Water pipe insulation 1 Thermal insulation work on pipes Cold hot water pipes require thermal insulation to prevent condensation on the pipe surface whil...

Страница 14: ...ystem and the lowest indoor unit m 100 MPa C Vertical separation between the top of the system and the hydro unit m 100 MPa A D 0 25 0 9 d B D 0 25 0 9 e C D 0 25 0 7 f The design pressure of the expansion vessel is 1 1 A C MPa or above Calculate the tank volume by assigning D that satisfies d to f to formula c Please choose ε for using antifreeze solution on the type and temperature range used ε ...

Страница 15: ...factory Set the address switch to an address that equals the address of the outdoor units that are connected to the hydro unit plus 1 Please refer to the outdoor unit installation manual 8 Test run Before commencing a test run please check the following After installing piping and wiring the indoor units and hydro units check to see again that there is no refrigerant leakage water leakage the indo...

Страница 16: ...7 WEIGHT YEAR OF MANUFACTURE IP CODE SERIAL No kg IP24 HYDRO UNIT MAXIMUM WATER PRESSURE 0 8MPa 8 0bar ALLOWABLE PRESSURE Ps 4 15MPa 41 5bar REFRIGERANT R32 RATED CURRENT A A RATED INPUT RATED CURRENT RATED INPUT Cooling Cooling FREQUENCY Hz UNIT RATING 220 230 240 50 60 50 60 50 60 H MODEL V kW kW Heating Heating WT09052X01_en book 16 ページ 2019年1月17日 木曜日 午前10時49分 ...

Страница 17: ...WT09052X01_en book 17 ページ 2019年1月17日 木曜日 午前10時49分 ...

Страница 18: ...WT09052X01_en book 18 ページ 2019年1月17日 木曜日 午前10時49分 ...

Страница 19: ...WT09052X01_en book 19 ページ 2019年1月17日 木曜日 午前10時49分 ...

Страница 20: ...the following EU regulations Low Voltage Directive 2014 35 EU Electromagnetic Compatibility Directive 2014 30 EU Machinery Directive 2006 42 EC Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WT09052X01_en book 20 ページ 2019年1月17日 木曜日 午前10時49分 ...

Отзывы: