7 FUNCTIONS
7.6 CC-Link IE Field Network Communication Function
89
7
■
Data storage content
Read parameters in the data storage of each channel.
The following table show the parameter configuration.
<Receive data configuration>
Index (lower byte) + index (upper byte) + su parameter length (bytes) + parameter
Data storage content is not writable. An error occurs in the RIWT instruction if the write is attempted.
Address code: 0H to 7H
Item
Description
Access code
24H
Attribute code
05H
Address code
00H to 07H (corresponding to channel numbers 1 to 8)
Data size
684 bytes
Data
1st to 684th bytes: Data storage saved in the IO-Link module (Default: 00H)
Address code: 10H to 17H
Item
Description
Access code
24H
Attribute code
05H
Address code
10H to 17H (corresponding to channel numbers 1 to 8)
Data size
684 bytes
Data
685th to 1368th bytes: Data storage saved in the IO-Link module (Default: 00H)
Address code: 20H to 27H
Item
Description
Access code
24H
Attribute code
05H
Address code
20H to 27H (corresponding to channel numbers 1 to 8)
Data size
680 bytes
Data
1369th to 2048th bytes: Data storage saved in the IO-Link module (Default: 00H)
Содержание CC-Link IE Field NZ2GF12A-60IOLH8
Страница 1: ...CC Link IE Field Network Waterproof Remote IO Link Module User s Manual NZ2GF12A 60IOLH8 ...
Страница 2: ......
Страница 30: ...28 3 PROCEDURES BEFORE OPERATION MEMO ...
Страница 100: ...98 8 MODULE FUNCTION BLOCKS MEMO ...
Страница 109: ...9 PROGRAMMING 9 2 Program Example of Setting Parameters Using a Dedicated Instruction 107 9 ...
Страница 116: ...114 9 PROGRAMMING 9 3 Example of Program to Communicate with an IO Link Device ...
Страница 118: ...116 10 MAINTENANCE AND INSPECTION MEMO ...
Страница 155: ...APPX Appendix 7 Additional or Changed Functions 153 A MEMO ...
Страница 157: ...I 155 MEMO ...
Страница 161: ......