*1: Replaceable with Q Series large type input module QX11L.
*2: Replaceable with Q Series large type output module QY11AL.
*3: Replaceable with Q Series large type output module QY13L.
*4: Replaceable with Q Series large type output module QY23L.
*5: Replaceable with Q Series large type output module QY51PL.
*6: Replaceable with one slot when Q Series output module QY81P is selected and conversion adapter ERNT-AQTY81 is used.
(Q Series large type base unit mountable)
* Replacement when using mixed voltage/current input for existing A (Large Type) Series module.
The 1-slot type conversion adapter can be used when using voltage input only or current input only.
MELSEC-A Series
module model
Input/Output
Conversion adapter (2-slot type)
MELSEC-Q Series
module model
Model
Shape
AY11A*
2
ERNT-AQTY10A
AX11*
1
ERNT-AQTX11
AY10A*
2
, AY10A-UL
AX11EU*
1
AY11AEU*
2
AY13*
3
AY13E*
3
ERNT-AQTY13
AY13EU*
3
Output
Input
ERNT-AQTY23
AY23*
4
AY51*
5
, AY51-UL
QX10 x 2 modules
QY50 x 2 modules
QY22 x 2 modules
AY51-S1*
5
ERNT-AQTY51
AY81*
6
AY81EP*
6
QY18A x 2 modules
QY10 x 2 modules
QY80 x 2 modules
Terminal block
(38-points)
MELSEC-A Series
MELSEC-Q Series
MELSEC-A Series
module model
Input/Output
Conversion adapter (2-slot type)
MELSEC-Q Series
module model
Model
Shape
(Voltage/Current mixed input)
A68AD
ERNT-AQT68AD-GH
A68AD-S2
(Voltage/Current mixed input)
A68ADN
(Voltage/Current mixed input)
A616AD
(Voltage input)
ERNT-AQT616AD
A616AD
(Current input)
Output
Input
ERNT-AQT616DA
A616DAV
A616DAI
Q64AD-GH x 2 modules*
Q68DAVN x 2 modules
Q68ADV x 2 modules
Q68DAIN x 2 modules
Q68ADI x 2 modules
Terminal block
(38-points)
Terminal block
(18-points)
x 2 modules
MELSEC-A Series
MELSEC-Q Series
(a) Conversion adapter
1) 1-slot type (Mountable to Q Series large type base unit)
Separate adapter are available for the I/O module, analog module and high-speed counter module.
The 1-slot type conversion adapter can also be mounted on the Q Series large base unit.
Refer to Section "2.1.2 Upgrade to Q Series using Q Series large type base unit and I/O modules".
2) 2-slot type (Not mountable to Q Series large type base unit)
(a) For I/O module
(b) For analog module
Terminal block
(18-points)
x 2 modules
MELSEC-A Series
module model
Mountable conversion adapter fixing mount
MELSEC-Q Series
module model
Base adapter model
ERNT-AQB68
A38B
,
A38HB
A38B-UL
A68B, A68B-UL
A58B, A58B-UL
A35B, A35B-UL
ERNT-AQB35
A65B, A65B-UL
ERNT-AQB65
A55B, A55B-UL
Q65B
,
Q55B
A32B, A32B-UL
A62B
A52B
Q68B
Q35B
ERNT-AQF12 ERNT-AQF8 ERNT-AQF5 ERNT-AQF3
ERNT-AQB58
Q68B
ERNT-AQB35
Q38B
,
Q38DB
ERNT-AQB65
Q68B
ERNT-AQB55
Q65B
,
Q55B
ERNT-AQB32
Q33B
ERNT-AQB62
Q63B
,
Q52B
ERNT-AQB52
Q52B
ERNT-AQB68
Q612B
ERNT-AQB38
Q38B
,
Q38DB
ERNT-AQB38
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Q312B
,
Q312DB
Conversion adapter fixing mount model
Remarks
Description
3-slot conversion adapter fixing mount
ERNT-AQF3
5-slot conversion adapter fixing mount
ERNT-AQF5
8-slot conversion adapter fixing mount
A conversion adapter fixing mount is
required to mount conversion adapters.
ERNT-AQF8
12-slot conversion adapter fixing mount
ERNT-AQF12
An adapter is used to mount a Q Series base unit using installation holes of the existing A (Large Type) Series
large type base unit.
(b) Base adapter
A mount to fix the conversion adapters.
(c) Conversion adapter fixing mount
•
Tips for using the upgrade tool manufactured by Mitsubishi Electric Engineering Co., Ltd.
(a) The programmable controller side modules are Q Series modules.
The specifications and functions may be different from those of the A (Large Type) Series modules.
Refer to the specification comparison in the corresponding module's transition handbook to confirm
compliance with the specifications and functions of the external device.
(b) Q Series main/extension base unit can be used with Q Series large type base unit. Select a base unit
according to the module configuration after replacement.
(Example of base unit combination)
• Main base unit: Q312B (Q Series standard type)
(Upgrade tool manufactured by Mitsubishi Electric Engineering Co., Ltd. is used.)
• Extension base unit: Q68BL (Q Series large type base unit)
Note that only the following CPU types can be used with Q Series large type base unit.
High Performance Model QCPU
Universal Model QCPU (except for Q00JCPU)
MELSECNET/H remote I/O station
(There are no restrictions on the CPU type if only the upgrade tool manufactured by Mitsubishi
Electric Engineering Co., Ltd. is used.)
• The 1-slot type conversion adapter may be difficult to mount depending on the existing wire size. In such
cases, consider using a Q Series large base unit.
Tip
45
2.1 Replace A/QnA (Large Type) Series with Q Series
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание Artisan MELSEC-A
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 25: ...MEMO 22 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 26: ...PartⅠ Hardware 23 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 58: ...MEMO 55 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 90: ...MEMO 87 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 110: ...MEMO 107 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 124: ...MEMO 121 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 131: ...MEMO 128 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 132: ...Part Ⅱ Programming 129 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 160: ...Part Ⅲ Application 157 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 192: ...MEMO 189 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 194: ...MEMO 191 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 195: ...MEMO 192 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...