![Mitsubishi Electric Apricot LS700 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/mitsubishi-electric/apricot-ls700/apricot-ls700_owners-handbook-manual_239306018.webp)
S y s t e m d e s c r i p t i o n a n d i n s t a l l a t i o n
LS700 HANDBOOK 1/7
Secondary Fan Specifications
This chassis has been tested for adherence to thermal
specifications using a single system fan and a full
complement of typical add-in cards and peripherals.
Because the power and cooling requirements for add-in card
components vary widely, this testing cannot guarantee that
every add-in card will meet its particular thermal
requirements in all possible system configurations.
If you integrate the system with add-in cards that draw
significant power, it is recommended that you install a front
cooling fan. If you add a secondary fan, it must meet these
specifications. Full installation information can be found in
chapter 2. Suitable fans can be obtained from your Apricot
supplier.
Parameter
Specification
Size
80 mm
Voltage
12 V DC
Airflow
26 CFM
Auxiliary Speaker Specifications
Some systems will be supplied with only a simple ‘beep’
speaker fitted to the motherboard. If you add an auxiliary
speaker, it must meet these specifications. Full installation
information can be found in chapter 2.
Parameter
Specification
Size
57 mm (approx)
Impedance
8 Ohms