![Mitsubishi Electric AnyWire DB A20 Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/mitsubishi-electric/anywire-db-a20/anywire-db-a20_handbook_238819049.webp)
6
REPLACING THE I/O MODULES
6
- 16
(5) Comparisons between AJ55TB2-8T and A20PB-08U
: Compatible,
: Partially changed, ×: Not compatible
*1
When used on 12VDC, consider the use of an external relay.
Specifications
AJ55TB2-8T
A20PB-08U
Compat-
ibility
Precautions for
replacement
Number of output points
8 points
8 points
Insulation method
External output
↔
Internal circuit:
Photocoupler
Internal circuit
↔
Transmission circuit:
Not insulated
External output
↔
Internal circuit: Not insulated
Internal circuit
↔
Transmission circuit:
Photocoupler
The insulated locations are
different.
Output type
Sink type
Sink type
Rated load voltage
12/24VDC
24VDC
12VDC cannot be used.
*1
Operating load voltage
range
10.2 to 30VDC
(peak voltage 30VDC)
21.6 to 27.6VDC
(ripple voltage 0.5Vp-p or less)
Operating voltage range is
different.
Maximum load voltage
0.5A/point
4A/common
0.2A/point
1.6A/common
The maximum load current
per point has decreased.
Check the specifications of
the load to be used.
Maximum inrush current
4A, 10ms or less
500mA or lower
Inrush current has decreased.
Check the specifications of
the load to be used.
Leakage current at OFF
0.1mA or lower
0.1mA or lower
Maximum voltage drop at
ON
0.9VDC or lower (TYP.) 0.5A
1.5VDC or lower (MAX.) 0.5A
1V or lower
Check the specifications of
the load to be used.
Response
time
OFF
ON
2ms or less
1ms or less
ON
OFF
2ms or less (resistance load)
1ms or less
Surge suppressor
Zener diode
None
×
The surge suppressor is not
built-in.
Common terminal
arrangement
8 points per common
(2-wire type terminal block)
8 points per common
(2-wire type terminal block)
Operation indicator
ON indication (LED)
ON indication (LED)
External wiring method
24-point terminal block (M3 screw)
Transmission circuit included
20-point terminal block (M3 screw)
Transmission circuit included
Wiring must be changed.
Existing wires can be used but
applicable crimping terminals
are different.
For details, refer to Section
6.3.
Applicable wire size
0.75 to 2mm
2
0.3 to 1.25mm
2
(when the following applicable crimping
terminals are used: 0.75 to 2mm
2
)
Applicable crimping
terminal
1.25-3, 1.25-YS3A,
2-S3, 2-YS3A
V1.25-3, V1.25-YS3A,
V2-S3, V2-YS3A
For wire sizes 0.75 to 2mm
2
R2-3SL, RAV2-3SL, RAP2-3SL,
VD2-3S, VD2-3.5SS, VD2-3.5S,
VDAV2-3.5SS, VDAV2-3.5S
External
power
supply
Voltage
10.2 to 30VDC
–
–
External power supply for the
A20PB-08U is unnecessary.
Current
30mA
(24VDC TYP. per 1 common)
–
–
I/O module
power
supply
Voltage
15.6 to 27.6VDC
(peak voltage 27.6VDC)
21.6 to 27.6VDC
(ripple voltage 0.5Vp-p or less)
Operating voltage range is
different.
Current
55mA
21mA
Because the external power
supply and the I/O module
power supply are shared, the
consumed current is
decreased.
External dimensions
50(H) × 114(W) × 66(D) mm
40(H) × 100(W) × 60(D) mm
The shape is different.
Installation method
Screw mounted
Screw mounted
×
Because mounting hole size is
different, reworking is
required.
Mounted to DIN rail
Mounted to DIN rail
The A20PB-08U can be
mounted to the existing DIN
rail.
Weight
0.3kg
0.13g