3. SPECIFICATIONS
MELSEC-A
3-1
3. SPECIFICATIONS
This section explains the AJ71PB96F/A1SJ71PB96F the general specifications, performance
specifications, and transmission specifications.
3.1 General
Specification
This section explains the AJ71PB96F/A1SJ71PB96F general specifications.
Table 3.1 General Specification
Item Specifications
Ambient operating
temperature
0 to 55
°
C
Ambient storage temperature
-20 to 75
°
C
Ambient operating humidity
10 to 90%RH, Non-condensing
Ambient storage humidity
10 to 90%RH, Non-condensing
Frequency
Acceleration
Amplitude
No. of sweeps
10 to 57Hz
—
0.075mm
(0.003inch)
Vibration resistance
57 to 150Hz
9.8m/s
2
{1G}
—
10 to 57Hz
—
0.035mm
(0.001inch)
57
to
150Hz
4.9m/s
2
{0.5G}
—
Shock resistance
Conforming to JIS B3501, IEC 1131-2
(147m/s
2
{15G}, 3 times in each of 3 directions X Y Z)
Operating ambience
No corrosive gases
Operating elevation
2000m (6562 feet) max.
Installation location
Control panel
Over voltage category
*
1
II max.
Pollution level
*
2
2 max.
*1: This indicates the section of the power supply to which the equipment is assumed to be
connected between the public electrical power distribution network and the machinery within the
premises. Category II applies to equipment for which electrical power is supplied from fixed
facilities. The surge voltage withstand level for up to the rated voltage of 300V is 2500V.
*2: This index indicates the degree to which conductive material is generated in terms of the
environment in which the equipment is used. Pollution level 2 is when only non-conductive
pollution occurs. A temporary conductivity caused by condensation must be expected
occasionally.
10 times each in
X, Y, Z directions
(for 80 min.)
Conforming to
JIS B3501,
IEC 1131-2
Under intermittent
vibration
Under continuous
vibration