3
*1
This setting is applicable to the AJ61BT11 of hardware version F or later and
the A1SJ61BT11 of hardware version G or later. For the modules with other
versions, the setting is "1 station" and "4 stations" only.
*2
Each of Ver.1.10 compatible CC-Link cables, CC-Link dedicated cables
(Ver.1.00), and CC-Link dedicated high-performance cables cannot be used
together with other cable types.
If different cable types are used together, normal data transmission is not
guaranteed.
Also attach the terminating resistor which matches the cable. (Refer to
section 5.1)
RAS function
• Auto return function
• Slave station cutoff function
• Error detection by the link special relay/register
Number of parameter
registration to
E
2
PROM
10000 times
Number of occupied
I/O points
32 points (I/O assignment: special 32 points)
Internal current
consumption (5VDC)
AJ61BT11:0.45A, A1SJ61BT11:0.4A
Weight AJ61BT11:0.4kg
,
A1SJ61BT11:0.25kg
Item