6. Electrical work
CHECK
CHECK
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
CHECK
CHECK
CHECK
2) For wireless remote controller (Fig. 6-10)
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.
1
Going to the function select mode
Press the
CHECK
button
F
twice continuously.
(Start this operation from the status of remote controller display turned off.)
CHECK
is lighted and “00” blinks.
Press the temp button
C
once to set “50”. Direct the wireless remote control-
ler toward the receiver of the indoor unit and press the
h
button
A
.
2
Setting the unit number
Press the
temp buttons
C
and
D
to set the unit number “00”. Direct the
wireless remote controller toward the receiver of the indoor unit and press the
min
button
B
.
3
Selecting a mode
Enter 04 to change the power voltage setting using the
temp buttons
C
and
D
. Direct the wireless remote controller toward the receiver of the indoor
unit and press the
h
button
A
.
Current setting number:
1 = 1 beep (1 second)
2 = 2 beeps (1 second each)
3 = 3 beeps (1 second each)
4
Selecting the setting number
Use the
temp buttons
C
and
D
to change the power voltage setting to 01
(240 V). Direct the wireless remote controller toward the sensor of the indoor
unit and press the
h
button
A
.
5
To select multiple functions continuously
Repeat steps
3
and
4
to change multiple function settings continuously.
6
Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit and
press the
button
E
.
Note: Whenever changes are made to the function settings after installation
or maintenance, be sure to record the changes with a mark in the “Setting”
column of the Function table.
6.3.. Function setting on the remote controller
Refer to the indoor unit operation manual.
Fig. 6-10
Function table
Select unit number 00
Mode
Settings
Mode no.
Setting no. Initial setting
setting
Power failure automatic recovery
Not available
01
1
Available
*1
2
Ο
*2
Indoor temperature detecting
Indoor unit operating average
02
1
Ο
Set by indoor unit’s remote controller
2
Remote controller’s internal sensor
3
LOSSNAY connectivity
Not Supported
03
1
Ο
Supported (indoor unit is not equipped with outdoor-air intake)
2
Supported (indoor unit is equipped with outdoor-air intake)
3
Power voltage
240 V
04
1
220 V, 230 V
2
Ο
Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller])
Mode
Settings
Mode no. Setting no. Initial setting
setting
Filter sign
100Hr
07
1
2500Hr
2
Ο
No filter sign indicator
3
Fan speed
Silent
08
1
Standard
2
Ο
High ceiling
3
No. of air outlets
4 directions
09
1
Ο
3 directions
2
2 directions
3
Installed options (high-performance filter)
Not supported
10
1
Ο
Supported
2
Up/down vane setting
Equipped with vanes (vanes angle setup
3
)
11
1
Equipped with vanes (vanes angle setup
1
)
2
Equipped with vanes (vanes angle setup
2
)
3
Ο
*1 When the power supply returns, the air conditioner will start 3 minutes later.
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.