![Miteq DNB1-11.2TR Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/miteq/dnb1-11-2tr/dnb1-11-2tr_manual_1807877035.webp)
Operation | 27
1/3 Rack Block Downconverters (Option 17)
DNB1-XTR, Rev.N, 8/14/2012
®
FREQUENCY BAND NUMBER INFORMATION = BNM (Block Converters Only)
There is no SET command.
The QUERY command required no parameters.
Command
Command
Parameters
Parameters
Remote Command Sequence: $BNM
Unit Response:
$BNMb
BNM: Band number indicator
b: Single-digit ASCII numeric character representing number of Bands
INTERNAL CALENDAR/CLOCK = CLK
The SET command requires a twenty-character parameter that sets the date and time of the Internal Calendar/Clock.
Command
Command
Parameters
Parameters
Remote Command Sequence: $CLKYyyyyMmmDddHhhNnnSss
Unit Response:
$CLK
The QUERY command requires no parameters.
Command
Command
Parameters
Parameters
Remote Command Sequence:
?CLK
Unit Response:
?CLKYyyyyMmmDddHhhNnnSss
Y: Year indicator
yyyy: Year, Four-digit ASCII numeric characters.
M: Month indicator
mm: Month, Two-digit ASCII numeric characters
D: Day indicator
dd: Day, Two-digit ASCII numeric characters
H: Hour indicator
hh: Hour, Two-digit ASCII numeric characters
N: Minute indicator
nn: Minute, Two-digit ASCII numeric characters
S: Second indicator
ss: Second, Two-digit ASCII numeric characters