3300 ICP Hardware User Guide
200
Release 3.3
OR
-
Click
Next
to accept the location displayed and continue. You see a read-only list of
the configurations you have made.
23. Click
Next
.
24. Ensure that the
Read manual instructions to complete the installation
check box is
selected, and click
Finish
. The
SWinstallGuide.txt
README file opens.
25. From the
SWinstallGuide.txt
file, record the parameters you need to complete step 31
of the next sub-procedure, "Rebooting".
26. Close the instructions window.
Rebooting
27. Launch your communications program that connects to the 3300 ICP serial port.
28. Type
reboot
, and press ENTER. The 3300 Controller reboots, and a Hyperterminal
window (RTC) opens on the installer's laptop/PC. You can also reboot by pressing the
Reset
button on the front panel of the 3300 Controller.
29. Press a key at the
Press any key to stop auto-boot
prompt. Note that you have 10
seconds to complete this step. If 10 seconds elapse before you press a key, the system
will auto-boot.
30. At [VXWorks Boot] type
c
, and press ENTER.
31. Change the following parameters as indicated in the RTC by inserting the information you
recorded in step 25 of "Installing 3.3 software (upgrading)" (note that the parameters are
case-sensitive):
-
Boot device : motfcc
-
File name : Boot_Install
-
Host inet : <the IP address of the FTP server PC host (your PC)>
-
User (u) : <user name for FTP server in PC host>
-
Ftp password (pw) (blank = use rsh) : <password for FTP server in PC host>
-
Flags (f) : 0x0 (for RTC only)
32. At [VXWorks Boot], type
@
, or press the
Reset
button on the controller.
Setting your purchased Mitel options
33. Launch a browser if you do not still have one running, and go to the IP address of the 3300
Controller (for example, http://<RTC IP address>). You see the 3300 ICP ESM login page.
Timer:
The system takes approximately 10 minutes to copy the files to the specified
location.
Tip:
If you miss the 10-second timeout, manually reset the controller by pressing the
Reset
button. The RTC opens, and you once again have 10 seconds to complete step 29.
Timer:
The system takes approximately 30 minutes to re-format the hard drive and install
the software.
Note:
Your laptop/PC must have the same subnet address as the RTC IP (for example,
192.168.1.x, where x is a variable) to launch ESM.
Содержание Navigator 3300 ICP
Страница 1: ...HARDWARE USER GUIDE ...
Страница 2: ......
Страница 9: ...Chapter 1 Before You Begin ...
Страница 10: ...3300 ICP Hardware User Guide 2 Release 3 3 ...
Страница 14: ...3300 ICP Hardware User Guide 6 Release 3 3 ...
Страница 15: ...Chapter 2 Specifications ...
Страница 16: ...3300 ICP Hardware User Guide 8 Release 3 3 ...
Страница 95: ...Specifications Release 3 3 87 ...
Страница 117: ...Chapter 3 Installing ...
Страница 118: ...3300 ICP Hardware User Guide 110 Release 3 3 ...
Страница 150: ...3300 ICP Hardware User Guide 142 Release 3 3 Backplane Connector Arrangements Peripheral Wiring Backplane ...
Страница 180: ...3300 ICP Hardware User Guide 172 Release 3 3 ...
Страница 181: ...Chapter 4 Install Upgrades and FRUs ...
Страница 182: ...3300 ICP Hardware User Guide 174 Release 3 3 ...
Страница 239: ...Chapter 5 Programming ...
Страница 240: ...3300 ICP Hardware User Guide 232 Release 3 3 ...
Страница 243: ...Chapter 6 Troubleshooting ...
Страница 244: ...3300 ICP Hardware User Guide 236 Release 3 3 ...
Страница 255: ...Troubleshooting Release 3 3 247 Troubleshoot the DID Loop Tie Trunk Card Troubleshoot the DNI Line Card ...
Страница 257: ...Troubleshooting Release 3 3 249 Troubleshoot LS GS Trunk Card ...
Страница 258: ...3300 ICP Hardware User Guide 250 Release 3 3 ...
Страница 259: ...Troubleshooting Release 3 3 251 Troubleshoot the ONS Line Card Troubleshoot the ONS CLASS CLIP Card ...
Страница 266: ... Trademark of Corporation Copyright 2003 Corporation All rights reserved Mitel Networks Mitel Networks ...