GX Gateway Hardware Installation Guide
23
Cables
Gigabit Ethernet Connection (RJ-45)
Caution:
Always use standard telecommunication cables with a minimum of 26 AWG wire gauge.
•
Gigabit Ethernet requires all four pairs to be present.
•
Category 5 cables can be used for 10/100 Base T-Connections.
•
Category 5e or 6 cables are recommended for Gigabyte Ethernet.
•
It is possible to use either a crossover or a straight Ethernet cable as the Mitel GX Gateways
perform automatic MDI/ MDIX detection, meaning that they adapt to the type of cables connected to
them. The Auto MDI/ MDIX feature only works when the unit are configured in auto detect mode,
which is the default mode.
Pin Name
Description
TIA/EIA 568A
TIA/EIA 568B
1
Bl_DA+/Tx+
Bi-directional pair A+
(T)
white/green
white/orange
2
Bl_DA-/Tx-
Bi-directional pair A-
(Transmit-)
green
orange
3
Bl_DB+/Rx+
Bi-directional pair B+
(R)
white/orange
white/green
4
Bl_DC+
Bi-directional pair C+
blue
blue
5
Bl_DC-
Bi-directional pair C-
white/blue
white/blue
6
Bl_DB-/Rv-
Bi-directional pair B-
(Receive -)
orange
green
7
Bl_DD+
Bi-directional pair D+
white/brown
white/brown
8
Bl_DD-
Bi-directional pair D-
brown
brown