TD
34/1531-ANF901 43 B1 2016-03-31
Installation Guide
9
3.4 OPERATING MODE
Besides normal operation the product can be operated in three other modes, that is,
Boot Mode, Demonstration Mode and Troubleshoot Mode.
3.4.1 NORMAL OPERATION
All configuration and settings for the product’s software, such as maintenance, software
upgrade and troubleshooting, are performed in the web user interface described in the
product’s user documentation.
3.4.2 BOOT MODE
If the software cannot be accessed, the product can be set in Boot Mode from the web
user interface. From this interface, it is possible to install new software, start
Troubleshoot Mode, see settings and to reset the module back to factory default
settings
1
.
Placing the product in Boot Mode is performed manually by the user but if the product
detects several major errors the module can place itself in Boot Mode.
1. Network settings such (IP address, Host name, etc.) will not be changed when resetting back to factory default.
* also used if the Power parameter conflicts with the actual setup.
Red
Red
Blue
Blue
Yellow
Yellow
Status LED
Blue
Mode LED
Blue
Blue
Yellow
Yellow
Blue
Status OK
Starting up/shutting down
Feedback
(1 sec.)
Error/fault
Warning
Boot mode
Demonstation mode
Waiting for automatic
startup (1 min.)
Troubleshoot mode and
during firmware upgrade
Mass storage mode
Standby module synchronized
Standby module during
synchronization
Yellow
Power LED
Blue
Blue
Yellow
Status LED
Mode LED
Blue
Blue
Confirmation is done and settings
can be activated
Secured settings
Indicates that manual confirmation is required
Red
Power LED
Closing down caused by
low voltage
Power
Power OK
Blue
Red
Low voltage*
Active module during
synchronization
Active module synchronized
Blue
Blue
Red
Blue