3300 ICP Technician’s Handbook
Restore a Database
Use this procedure to restore a previously saved database.
Tip:
The system does not allow you to log in during the restore and reset
period. Once the system has completed the restore and reset, you should
see "deleting/ipservicesdb.tar" in the RTC. This is a good indication that you
can log back in to the System Administration Tool.
Tip:
Restoring a database from one platform to another requires that the two
databases match in the modules and add-ons, including embedded analog
circuits programmed. As an example, the database from a controller
programmed with TDM modules cannot be restored on an MXe Server unless
all of the TDM configurations are deleted first. Furthermore, the IP address
of the source platfom (where the backup was done) and the destination
platform (where the backup is restored) must match; otherwise, the Restore
will fail (see the following Note for an exception to this rule). To avoid failure,
change the IP address in the destination before restoring; then, after the
restore, change it back.
Note:
MCD 4.0 SP4 and MCD 5.0 controllers will accept databases from
other controllers; there is no need to match the IP addresses first. Certain
rules apply when restoring these databases, particularly in SDS-sharing
networks. See “Restoring Foreign 3300 ICP Databases” in the System
Administration Tool Help for more information.
Restore path
Restore allowed?
Prior to release 3.3 database
No
3.3 to release 4.1 or later
Yes
MX database to MXe
No - if AOB was configured
Yes - if you first delete the AOB configuration
Other controller database to
MXe Server
No - if other controller has TDM interfaces or
CIMs are configured
Yes - if delete all TDM configs, all CIM
configs, voice mail and record-a-call
Database from one system with
embedded analog circuits to
another system with embedded
analog circuits
No - if systems provide for different numbers
of embedded analog circuits
Yes - if the number of embedded circuits
match
Note:
The LX and the MXe Server have no embedded circuits.
Note:
You cannot restore a database backed up from a 3300 system (LX, AX,
MXe) to an MXe Server.
Содержание 3300
Страница 1: ...MITEL 3300 IP Communications Platform Technician s Handbook Mitel Communications Director Release 5 0 ...
Страница 10: ...x Enter document Title using Variable ...
Страница 11: ...Chapter 1 Getting Started ...
Страница 12: ...2 3300 ICP Technician s Handbook ...
Страница 20: ...10 3300 ICP Technician s Handbook ...
Страница 21: ...Chapter 2 Initial Setup ...
Страница 22: ...12 3300 ICP Technician s Handbook ...
Страница 48: ...38 3300 ICP Technician s Handbook ...
Страница 49: ...Chapter 3 Installation and Programming ...
Страница 50: ...40 3300 ICP Technician s Handbook ...
Страница 91: ...Chapter 4 Software Installation ...
Страница 92: ...82 3300 ICP Technician s Handbook ...
Страница 124: ...114 3300 ICP Technician s Handbook ...
Страница 125: ...Chapter 5 Maintenance ...
Страница 126: ...116 3300 ICP Technician s Handbook ...
Страница 166: ...156 3300 ICP Technician s Handbook ...
Страница 167: ...Chapter 6 Install and Replace Units ...
Страница 168: ...158 3300 ICP Technician s Handbook ...
Страница 214: ...204 3300 ICP Technician s Handbook Figure 71 MXe MXe Server RTC E2T APC on the Main Board bottom view ...
Страница 247: ...Appendix A Hardware Reference ...
Страница 248: ...238 3300 ICP Technician s Handbook ...
Страница 251: ...241 Hardware Reference Figure 90 AX Controller Card View Figure 91 AX Controller Rear Panel ...
Страница 252: ...242 3300 ICP Technician s Handbook Figure 92 MXe Controller Front Panel Figure 93 MXe Controller Back Panel Redundant ...
Страница 254: ...244 3300 ICP Technician s Handbook Figure 97 MXe Server Back panel Figure 98 CX Controller Front Panel ...
Страница 255: ...245 Hardware Reference Figure 99 CXi Controller Front Panel Figure 100 CX and CXi Controller Back Panel ...
Страница 256: ...246 3300 ICP Technician s Handbook Figure 101 CX II Controller Front Panel Figure 102 CXi II Controller Front Panel ...
Страница 279: ...Appendix B Installation Planner ...
Страница 280: ...270 3300 ICP Technician s Handbook ...
Страница 308: ...298 3300 ICP Technician s Handbook ...
Страница 309: ...Appendix C Typical Network Configurations ...
Страница 310: ...300 3300 ICP Technician s Handbook ...
Страница 338: ...328 3300 ICP Technician s Handbook ...
Страница 339: ...Appendix D Status LEDs ...
Страница 340: ...330 3300 ICP Technician s Handbook ...
Страница 370: ...360 3300 ICP Technician s Handbook SX 200 Bay LEDs BCC III Figure 160 Peripheral Cabinet FIM LEDs ...
Страница 378: ...368 3300 ICP Technician s Handbook ...
Страница 379: ...Appendix E FRU Part Numbers ...
Страница 380: ...370 3300 ICP Technician s Handbook ...
Страница 390: ...380 3300 ICP Technician s Handbook ...
Страница 391: ...Appendix F System Capacity and Parameters ...
Страница 392: ...382 3300 ICP Technician s Handbook ...
Страница 402: ...392 3300 ICP Technician s Handbook ...
Страница 403: ...Appendix G Older Hardware and Software ...
Страница 404: ...394 3300 ICP Technician s Handbook ...
Страница 410: ...400 3300 ICP Technician s Handbook Figure 163 Windows 2000 FTP Site Tab Figure 164 Windows 2000 Security Accounts Tab ...
Страница 418: ...408 3300 ICP Technician s Handbook ...
Страница 431: ......