MITECH Garden/Tower-MICRO Series Скачать руководство пользователя страница 1

 
 
Garden/Tower-MICRO Rev. 2 - 03/2015 – 

MITECH srl reserves the right to change the information in this document without warning.

 

 

    
    

 

English

    

    
    

Series 

 

G

G

G

G

G

G

G

G

A

A

A

A

A

A

A

A

R

R

R

R

R

R

R

R

D

D

D

D

D

D

D

D

E

E

E

E

E

E

E

E

N

N

N

N

N

N

N

N

----

----

T

T

T

T

T

T

T

T

O

O

O

O

O

O

O

O

W

W

W

W

W

W

W

W

E

E

E

E

E

E

E

E

R

R

R

R

R

R

R

R

    

    

M

M

M

M

M

M

M

M

IIII

IIII

C

C

C

C

C

C

C

C

R

R

R

R

R

R

R

R

O

O

O

O

O

O

O

O

    

    

 

 

Use and installation manual

Содержание Garden/Tower-MICRO Series

Страница 1: ...nt without warning English Series G G G G G G G GA A A A A A A AR R R R R R R RD D D D D D D DE E E E E E E EN N N N N N N N T T T T T T T TO O O O O O O OW W W W W W W WE E E E E E E ER R R R R R R R M M M M M M M MI I I I I I I IC C C C C C C CR R R R R R R RO O O O O O O O Use and installation manual ...

Страница 2: ...s 6 Wall mounting 6 Ground mounting 7 Fixing the column to the base 8 Inserting the cover and closing the column 9 Mounting the lamp 10 Examples of installation 11 Example of how to protect an independent building 12 Column supply 13 Microwave Barrier Detection System 14 Introduction 14 Technical specifications and connections 15 Warnings and general characteristics 16 Notes 17 18 19 ...

Страница 3: ...ut protection cover IMPORTANT Power the device using the 13 8 Vdc stabilised voltage only In order for the column to work correctly ensure the power voltage never falls below 12 Vdc It is imperative you switch on the temperature control system for both internal and external installations power supply 24Vac ...

Страница 4: ...n components 2 3 1 4 Part Part Part Part Quantity Quantity Quantity Quantity Description Description Description Description 1 1 Aluminum profile 2 1 IR polycarbonate cover 3 1 Upper cover 4 1 Lower cover 5 1 Receiver or transmitter microwave device 6 1 Tamper 5 6 ...

Страница 5: ... TW e GAR 1 Wall fixing base 2 TW e GAR 1 Bracket 3 TW e GAR 4 Screws with washers 4 TW e GAR 3 Clamps 5 solo GAR 1 Upper lamp cover 6 solo GAR 1 Lamp holder Optional Optional Optional Optional Pa Pa Pa Part rt rt rt Quantity Quantity Quantity Quantity Description Description Description Description 7 only GAR GAR LAMP CO WH Globe 32 cm diameter colour cognac CO or white WH 8 TW e GAR GAR POW Dual...

Страница 6: ...e optical path of the transmitter used by the receiver column is not exposed to direct sunlight at dawn and sunset 4 If possible do not use switching power supplies that cause disturbance to power supplies when amplified by optically synchronized systems Mounting options Columns may be mounted in two ways 1 with a specific wall mounting base 2 with a specific ground mounting base Which in turn may...

Страница 7: ...inth This fixing method is the most secure It requires a cement base in which to anchor the clamps provided Ensure the plinth contains a tube Ø 20 mm through which to thread the cables with fixing gussets Drill 3 holes of Ø 8 mm in the ground level with the base fixing holes Insert TE M8 steel gussets not supplied and fix the base 210 200 210 Ø33 200 Ø33 200 ...

Страница 8: ...base guide Insert the aluminium profile into the base guide and into the relevant slot in the lower cover Insert the connecting bracket between the lower cover and the aluminium profile Screw 2 TE M6x20 screws through the bracket and the base and 2 TE M6x25 screws through the bracket and the profile M6x25 M6x20 squadretta ...

Страница 9: ...20 Inserting the cover and closing the column Insert the polycarbonate cover from above making it slide down as far as the column base and inserting it into the lower cover Place the upper cover and screw it to the column by means of 2 O ring screws supplied ...

Страница 10: ...erly threaded Screw the cover to the column by means of 2 O ring screws supplied Connect the wires to the lamp holder terminal Fix the lamp holder to the cover using the 2 Allen screws found at the sides 5 mm spanner Insert the bulb Place the lamp shade on the supporting base and turn it clockwise Fix it in place using the screw found on the supporting base Viti a brugola vite ...

Страница 11: ...s perimeter check 4 sides perimeter check solution 2 4 complete bidirectional columns each column has a TX one RX device Check of just one side Check of just one side Check of just one side Check of just one side solution 3 2 terminal columns each column has just one TX or RX device To be used when it is sufficient to protect just one side because the remaining perimeter is already protected or in...

Страница 12: ...ilding Example of how to protect an independent building The electromagnetic waves transmitted are high frequency to guarantee maximum protection WARNINGS Ensure no interference is caused by the presence of photocells for automatic gates or microwave sensors as these may blind the barriers ex video infrared lighting for night vision high frequency electromagnetic waves transmitted by the columns c...

Страница 13: ... of supply of RX terminal column using the GAR POW dual power supply unit 220 Vac 6 5 4 3 2 1 GND 12 Vdc 12 Vdc Vin WARNINGS To function correctly the column needs 230 Vac filtered and stabilized voltage supply Therefore check the electrical system before powering up GARPOW MICROWAVE ...

Страница 14: ... waves processes them into an electric signal and analyses this signal The person who crosses the DZ triggers the modulation of the signal at the entry of the RU The depth of the modulation and the form of signal depend on the size and mass of the person the place where the area is crossed the relief of the land and the speed of movement IMPORTANT To use no aligning kit or programming software are...

Страница 15: ...it maximum current constant or alternate maximum voltage 30 mA 72 V Minimum signal duration 5 s Operating frequency da 24 00 a 24 25 GHz C C C Connections onnections onnections onnections After fixing the base see the installation options on p 6 and how to fix the column to the base on p 8 of the manual and powering the column see page 15 follow the following instructions 1 carry out the manual ad...

Страница 16: ...ve surfaces fences ground etc it is necessary to change the position and orientation of the aerials 5 A possible cause for the false alarms of the device might be the RU unit receiving the emissions of different Tus 6 Carry out testing for no less than 3 days and check the crossing sensing at least twice in 24 hours 7 The device works properly and does not give false alarms even in the event of di...

Страница 17: ...Garden Tower MICRO Use and installation manual Page 17 of 20 NOTES ...

Страница 18: ...Garden Tower MICRO Use and installation manual Page 18 of 20 ...

Страница 19: ...Garden Tower MICRO Use and installation manual Page 19 of 20 ...

Страница 20: ... manual Page 20 of 20 MITECH S r l Main Office Via Roncaglia 14 20146 Milano Italy Telefono 39 02 48006383 Fax 39 02 48025620 Production site Via Ramazzone 23 43010 Fontevivo Parma Italy Email tech mitech security com www mitech security com ...

Отзывы: