background image

 

http://www.tyan.com 

106 

4.3.9      PCI Subsystem   

 

 

Above 4G Decoding   

Globally Enables or Disables 64bit capable Devices to be decoded in Above 4G 
Address Space(Only if System supports 64 bit PCI Decoding).   

Enabled

 

Disabled 

 

SR-IOV Support 

If system has SR-IOV capable PCIe devices, this option Enable or Disable Single 
root IO virtualization Support 

Enabled

 

Disabled 

 

PCI Express Settings 

Change PCI Express Devices Settings 
 
 
 
 
 
 
 
 
 

Содержание TYAN B8026G62FE10HR

Страница 1: ...GT62F B8026 Service Engineer s Manual ...

Страница 2: ...lity or warranties relating to fitness for a particular purpose or merchantability TYAN retains the right to make changes to produce descriptions and or specifications at any time without notice In no event will TYAN be held liable for any direct or indirect incidental or consequential damage loss of use loss of data or other malady resulting from errors or inaccuracies of information contained in...

Страница 3: ... limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to...

Страница 4: ...re There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Dispose of used battery according to manufacturer instructions and in accordance with your local regulations VCCI A この装置は クラスA情報技術装置です この装置を家庭環境で使用すると 電波妨害を引き起こすことがあります この場合には使用者が適切な対策を 講ずるよう要求されることがあります Safety IEC EN 60950 1 This equipment is compliant ...

Страница 5: ...s list and accessories describes the external components gives a table of key Chapter2 Setting Up This chapter Covers procedures on installing the CPU memory modules add on card and hard drives Give an overview about theGT62F B8026 barebone from an overall angle Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components ...

Страница 6: ...se of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not be in the way of foot traffic Follow all warnings and cautions in this manual and on the unit case Do not push objects in the ventilation slots as they may touch high voltage components and result in...

Страница 7: ...ons are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning This symbol indicates the presence of hazardous energy circuits or electric shock hazards Refer all servicing to qualified personnel Warning This symbol indicates the presence of a hot surface or hot component If this surface is contacted th...

Страница 8: ... or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rack by yourself a minimum of two people are needed to move a rack Do not attempt to move a fully loaded rack Remove equipment from the rack before moving it Do not attempt to move a rack on an incline that is greater than 10 degrees from the h...

Страница 9: ...s power to the rack is not overloaded This will reduce the risk of personal injury fire or damage to the equipment The total rack load should not exceed 80 percent of the branch circuit rating Consult the electrical authority having jurisdiction over your facility wiring and installation requirements Verify that the AC power supply branch circuit that provides power to the rack is not overloaded T...

Страница 10: ...ry to temperatures higher than 60 C 140 F The system battery is not replaceable If the battery is replaced by an incorrect type there is danger of explosion Replace the battery only with a spare designated for your product Do not attempt to recharge the battery Dispose of used batteries according to the instructions of the manufacturer Do not dispose of batteries with the general household waste T...

Страница 11: ...e gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider Examples of damage requiring service include The power cord extension cord or plug has been damaged Liquid has been spilled on the product or an object has f...

Страница 12: ...he Memory 36 2 1 5 Installing Hard Drives 39 2 1 6 Installing the Add On Card 41 2 2 Rack Mounting 44 2 2 1 Installing the Server in a Rack 45 2 2 2 Installing the inner Rails to the Chassis 45 2 2 3 Installing the Outer Rails to the Rack 47 2 2 4 Rack mounting the Server 47 Chapter 3 Replacing Pre Installed Components 49 3 1 Introduction 49 3 2 Disassembly Flowchart 49 3 3 Removing the Cover 50 3...

Страница 13: ...he Motherboard 76 Chapter 4 BIOS Setup 78 4 1 About the BIOS 78 4 2 Main Menu 80 4 3 Advanced Menu 82 4 4 Chipset Menu 113 4 5 AMD CBS Menu 118 4 6 Server Management 133 4 7 Security 138 4 8 Boot 143 4 9 Save Exit 146 Appendix I Fan and Temp Sensors 148 Appendix II Installing IO Plate for OCP Card 152 Appendix III Cable Connection Tables 156 Appendix IV FRU Parts Table 158 Appendix V Technical Sup...

Страница 14: ... system is capable of offering scalable 32 and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation GT62F B8026 not only empowers your company in today s demanding IT environment but also offers a smooth path for future application usage TYAN also offers theGT62F B8026 in a version that can support up to ten 2 5 Hot Swap SSDs HDDs NVMe GT62F B8026 uses rack mou...

Страница 15: ...D HDD Backplane Support SAS 12Gb s SATA 6Gb s Supported HDD Interface 10 SATA 6Gb s Notification The SAS SATA HDD backplane is connected to onboard SATA connection by default Please contact Tyan technical support if a discrete SAS HBA RAID adapter installed is required System Cooling Configuration FAN 4 4cm fans Power Supply Type RPSU Input Range AC 100 240V 9A Frequency 50 60 Hz Output Watts 650 ...

Страница 16: ...t left 1 M7106 R16 1F riser card for 1 PCI E Gen3 x16 slot Others 1 PCI E Gen3 x16 OCP 2 0 slot conn A conn B LAN Q ty Port 2 GbE ports 1 GbE dedicated for IPMI Controller Broadcom BCM5720 PHY Realtek RTL8211E Storage SATA Connector 10 SATA Controller Direct from AMD EPYC CPU Speed 6Gb s RAID N A Notification The 2 right most SATA SSDs HDDs 8 9 are not available when AMD EPYC 7002 Series Processor...

Страница 17: ...ironment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboa...

Страница 18: ...ing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Barebone 1 GT62F B8026 Barebone Manual 1 Quick Installation Guide Installation CD 1 TYAN Device Driver CD B8026G62FE10HR Specifications System Form Factor 1U Rackmount Chassis Model GT62F Dimension D x W x H 24 6 x 17 2 x 1 72 625 4 x 436 x 43 6mm Motherboard Name S8026GM2NRE Gross Weight 20 kg 44 lbs Net weight 10 5kg 23 5 lbs Front Panel B...

Страница 19: ...ge Max up to 180W Memory Supported DIMM Qty 16 DIMM slots DIMM Type Speed DDR4 ECC RDIMM LRDIMM 2666 2400 Capacity Up to 1 024GB RDIMM LRDIMM Memory channel 8 Channels per CPU Memory voltage 1 2V Notification LRDIMM is not supported when AMD EPYC 7002 Series Processors deployed in all configurations Please contact Tyan Technical Support for more details Expansion Slots PCI E 2 PCI E Gen3 x16 slots...

Страница 20: ... Ports USB 2 USB3 0 ports rear 2 USB3 0 ports front COM 1 DB 9 port COM1 1 header COM2 VGA 1 D Sub 15 pin port RJ 45 2 GbE ports 1 GbE dedicated for IPMI TPM Optional TPM Support Please refer to our TPM supported list System Monitoring Chipset Aspeed AST2500 Temperature Monitors temperature for CPU memory system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temp...

Страница 21: ...ke on LAN ACPI sleeping states S0 S1 S5 Operating System OS supported list Please refer to our AVL support lists Regulation FCC DoC Class A CE DoC Class A CB LVD Yes RCM Class A VCCI Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Barebone 1 GT62...

Страница 22: ...M1286G62F BP12E 10 B8026 HDD Backplane pre installed 1 M1716G75 Front Panel Board pre installed 1 M1620G62F D PDB or Tiger PDB pre installed 1 M7106 L16 1F Riser Board pre installed 1 M7106 R16 1F Riser Board pre installed GT62F B8026 B8026G62FV10HR LE Box Content 1 1U barebone with 10 fixed HDD bays 1 1 ERP1U 650W RPSU 80 Platinum DPS 650AB 14 D 1 S8026GM2NR LE system Board pre installed 4 4028 S...

Страница 23: ...owse to TYAN s website for service http www tyan com GT62F B8026 Accessory Kit 1 Sliding rail 1 CPU Heatsink 2 US Power Cord 2 EU Power Cord 1 Mounting Ear Kit x1 1 Air Duct 1 MEZZ card screw package 2 2 5 HDD screw package 1 I O Plate LAN Kit 1 I O Plate SFP Kit 2 Power Clip 1 QIG 1 Driver ...

Страница 24: ...he product 1 3 1 System Front View HDD Sequence B8026G62FV10HR NVMe1 NVMe3 NVMe5 NVMe7 NVMe9 NVMe0 NVMe2 NVMe4 NVMe6 NVMe8 HDD Sequence B8026G62FV10HR LE HDD1 SSD1 HDD3 SSD3 HDD5 SSD5 HDD7 SSD7 HDD9 SSD9 HDD0 SSD0 HDD2 SSD2 HDD4 SSD4 HDD6 SSD6 HDD8 SSD8 ...

Страница 25: ...Green off Blue Solid On Warning System normal Off System Normal Amber Off System Warning Amber Solid On System alert Amber HDD HDD Ready Off HDD Access Green Blinking HDD Ready Green Off HDD Access Blinking LAN1 Access Green Access Green Blinking Linking Green Off Off Link Green Off Link Green Off Link Off LAN2 Access Green Access Green Blinking Linking Green Off Off Link Green Off Link Green Off ...

Страница 26: ...A Port 9 1Gb RJ45 LAN3 from PHY dedicated for BMC IPMI 1 3 3 LED Definitions 1Gbps LAN Port LAN Indication 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Link Activity Right LED Speed No Link OFF OFF 10 Mbps Link Solid Green OFF Active Blinking Green OFF 100 Mbps Link Solid Green Solid Green Active Blinking Green Solid Green 1000 Mbps 1Gbps Link Solid Green Solid Amber Active Blinking Gree...

Страница 27: ...1 3 4 Internal View B8026G62FE10HR B8026G62FV10HR LE ...

Страница 28: ...wap SSDs HDDs 3 M1286G62F BP12E 10 B8026 HDD Backplane 4 4 cabled fans 5 CPU socket Heatsink 6 Memory Slots 7 PCIE3 0 SLOT x24 PESLOT2 8 PCIE3 0 SLOT x24 PESLOT1 9 OCP A Slot OCP1_A 10 OCP B Slot OCP1_B 11 1 1 ERP1U 650W RPSU 80 Platinum DPS 650AB 14 D 12 M1620G62F D PDB or Tiger PDB ...

Страница 29: ...prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static pad Most of the electrical and mechanical connections can be disconnected using your fingers It is recommended that you do not use needle nosed pliers to remove connectors as these ...

Страница 30: ...ssis of the unit case or the bare metal body of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static surface until you are ready to reinstall it Hold electronic circuit boards by the edges only Do not touch the components ...

Страница 31: ... Removing the Chassis Cover Follow these instructions to remove GT62F B8026 chassis cover 1 Remove the side screw on the chassis cover as in the small diagram 2 Loosen the Thumb screw on the back side of the chassis as in the small diagram in a counterclockwise direction 3 Push the cover in the direction of the arrow and take out the top cover from chassis kit ...

Страница 32: ...2 1 2 Removing the Air Duct 1 Remove the air duct from the chassis ...

Страница 33: ...driver to loosen the screws securing the force frame in a sequential order 3 2 1 Note The force frame will automatically eject after the captive screws are being released 2 By placing your both index fingers on the sides on the metal handle pull to release the rail frame Then lift the rail frame to its fully open position ...

Страница 34: ...tion observe the following NOTE During installation observe the following 1 Make sure to push the carrier frame with package towards the end of the rail frame until it clicks into place 2 Do not drop the carrier frame or touch the package pad to avoid component damage 5 Using your thumbs and forefinger remove the PnP cap by lifting it up vertically ...

Страница 35: ...rmly until it locks in place 7 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure the force frame in a sequential order 1 2 3 8 To secure the heatsink use a T30 Security Torx to tighten the screws Tighten the four screws in a diagonal sequence to secure the heat sink ...

Страница 36: ...to the motherboard 1 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly the memory slot locking levers lock automatically onto the indentations at the ends of the module ...

Страница 37: ...DIMM Location ...

Страница 38: ...H_G0 P0_D2_Umc1_CH_G1 P0_D2_Umc0_CH_H0 P0_D2_Umc0_CH_H1 NOTE 1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM 4 Dual rank DIMMs are recommended over single rank DIMMs 5 Un buffered DIMM can offer slightly better performance than registerd DIMM if po...

Страница 39: ...heGT62F B8026 supports 10 2 5 Hard Drives Follow these instructions to install a hard drive 2 5 Hard Disk Drive 1 Located at the 2 5 HDD tray 2 Press the locking lever to release the 2 5 SSD HDD tray 3 Pull out the 2 5 SSD HDD tray ...

Страница 40: ...the 4 screws to detach HDD tray bracket 5 Place a hard drive into the drive tray Use four screws to secure the HDD 6 Reinsert the HDD tray into the chassis 7 Press the locking lever to lock the 2 5 SSD HDD tray ...

Страница 41: ...pansion slot which is available with riser card The following instructions are for Add On card installation You may refer to the procedures below for the installation 1 Remove the screw of PCI E bracket and lift up the bracket 2 Release the screws on both sides of the riser card bracket as shown 3 Remove the PCI E cover shields from the chassis ...

Страница 42: ...4 Insert the PCI E card in the direction of arrows as shown ...

Страница 43: ...5 Screw the PCI E cards firmly to the riser card bracket ...

Страница 44: ...the necessary components the TYAN GT62F B8026 can be mounted in a rack using the supplied rack mounting kit Rack mounting kit Sliding Rails x 2 Mounting Ears including screws x 2 Screws Kit x 1 Mounting Brackets x 4 Installing the Server in a Rack Follow these instructions to mount the TYAN GT62F B8026 into an industry standard 19 rack Screws List No Screw Size Quantity Rail Kit A M5 washer 8pcs B...

Страница 45: ...nts have been installed and that the unit has been fully tested However to make the installation easier we suggest that you remove all HDD trays before you insert the chassis into the rack 2 2 2 Installing the inner Rails to the Chassis 1 Release and detach the inner rail from the sliding rail 2 Press the button in the direction of the arrow to release the inner sliding rail 3 Align the inner slid...

Страница 46: ... inner sliding rail forward to secure it to the chassis And secure the inner rail to the chassis with 2 screws 5 Screw the mounting ear to each side of TYAN GT62F as shown using two screws of 6 32 L5 3 D from the supplied screws kit ...

Страница 47: ...ure the outer rail to the rack using 8 M5 washer A screws for each side 2 2 4 Rack mounting the Server 1 Lift the unit and then insert the inner slide rails into the middle rails 2 Press the white button in the direction of the arrow to push the whole system into the rack ...

Страница 48: ...http www tyan com 48 3 Secure the mounting ears of chassis to the rack with 2 M5 15L C screws ...

Страница 49: ...ed components including the S8026GM2NRE S8026GM2NR LE Motherboard M1716G75 FPB Front Panel Board M1274G62B BP12 10 B8026 M1286G62F BP12E 10 B8026 Backplane M7106 L16 1F M7106 R16 1F Riser Card System Fan and M1620G62F D PDB Power Distribution Board etc 3 2 Disassembly Flowchart The following flowchart outlines the disassembly procedure ...

Страница 50: ... Follow Chapter 2 1 1 to remove the cover of GT62F B8026 3 4 Replacing the Riser Card 1 The GT62F B8026 has preinstalled 2 riser cards Release the 2 screw to lift the riser bracket from the chassis Remove the screw of PCI E bracket and lift up the bracket 2 Remove the PCI E cover shields from the chassis ...

Страница 51: ...http www tyan com 51 3 Remove the 2 screws to release the M7106 R16 1F riser card 4 Remove the 2 screws to release the M7106 L16 1F riser card ...

Страница 52: ...http www tyan com 52 3 4 1 Riser Card Features M7106 L16 1F Riser Card M7106 R16 1F Riser Card ...

Страница 53: ...ur system fans Disconnect the fan cable which you need to replace up 2 Take out the fan module from the chassis 3 Release the rubber screws and the push pins from the fan 4 Replace the failed fan module with a new one Follow the procedures described earlier in reverse order to reinstall ...

Страница 54: ...low these instructions to replace the M1274G62B BP12 10 B8026 M1286G62 BP12E 10 B8026 HDD Backplane 1 First pull the HDD trays slightly forwards to make the HDD BP Board easier to uninstall 5 Disconnect all the cables connected to the HDD Backplane 6 Remove the four screws securing the bracket and lift the bracket ...

Страница 55: ...http www tyan com 55 7 Remove the eight screws securing the bracket to the HDD backplane ...

Страница 56: ... 6 SAS SATA HDD Connectors 4 MINI SAS HD Connector connect to MB 2 MINI SAS Connector connect to MB 2 SATA connector connect to MB 1 2 10 Pin FAN connector connect to MB 6 8 Pin FAN connector connect to FAN 2 1 4Pin power connector connect to MB 2 2x5 pin JTAG connector 1 2x5 pin SGPIO connector connect to MB LEDs 10 Green LEDS for HDD activity 10 Red LEDS for HDD fault ...

Страница 57: ...ctor NVMe Connector NVMe Connector NVMe Connector SAS SATA PCIe HDD Connector SAS SATA PCIe HDD Connector SAS SATA PCIe HDD Connector SAS SATA PCIe HDD Connector SAS SATA HDD Connector SAS SATA HDD Connector SAS SATA HDD Connector SAS SATA HDD Connector SAS SATA HDD Connector SAS SATA HDD Connector Mini SAS Connector Mini SAS Connector SGPIO Connector Power Connector Power Connector FAN Connector ...

Страница 58: ...t View Rear View PCB Dimensions 420 4 36 7 2mm Thickness 2mm Layer 8 layers Integrated I O 10 HDD NVMe Connector 5 OCCulink Connector 6 FAN Connector 1 4X2pin Power Connector 1 4Pin Power Connector 2 SGPIO Header J12 J13 1 JTAG Header 2 SATA Connector ...

Страница 59: ...CCulink Connector OCCulink Connector OCCulink Connector OCCulink Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector HDD NVMe Connector SGPIO Header SGPIO Header Power Connector Power Connector FAN Connector FAN Connector FAN Connector FAN Connector FAN Connector FAN Con...

Страница 60: ...28 GND NC E1 E2 NC VCC3_AUX E3 E4 NC PE_RST_N_R E5 E6 NC PE_CLK_DP E7 E8 PE_CLK_DN GND E9 E10 PE_TX_DP0 PE_TX_DN0 E11 E12 GND PE_RX_DN0 E13 E14 PE_RX_DP0 GND E15 E16 NC PE_TX_DP3 E17 E18 PE_TX_DN3 GND E19 E20 PE_RX_DN3 PE_RX_DP3 E21 E22 GND PE_SMB_CLK E23 E24 PE_SMB_DAT HD_DP_EN_N E25 PE_WAKE_N P1 P2 NC DEV_SLP P3 P4 IFDET GND P5 P6 GND VDD_5_RUN P7 P8 VDD_5_RUN VDD_5_RUN P9 P10 HD_PRS_L HD_LED P1...

Страница 61: ...P10 HD2_PRS_L HD2_LED P11 P12 GND HD2_VDD12 P13 P14 VDD12 VDD12 P15 GND GND1 GND2 GND SATA8 9 SATA Connector Definition Pin Pin Definition GND 1 2 SAS_TX_DP8 SAS_TX_DN8 3 4 GND SAS_RX_DN8 5 6 SAS_RX_DP8 GND 7 GND GND1 GND1 GND FAN1 6 8 Pin FAN Connector Definition Pin Pin Definition CON_PWM 1 2 CON_PWM FAN_TACH 3 4 GND GND 5 6 FAN_TACH VDD_12 7 8 CON_PWM J1 JTAG Connector Definition Pin Pin Defini...

Страница 62: ... Mini SAS Connector Definition Pin Pin Definition GND A1 A2 SAS_TX_DP0 SAS_TX_DN0 A3 A4 GND SAS_TX_DP1 A5 A6 SAS_TX_DN1 GND A7 A8 SAS_SIO_CLK_A SAS_SIO_END_A A9 A10 GND SMB2_CLK3 A11 A12 GND SAS_TX_DP2 A13 A14 SAS_TX_DN2 GND A15 A16 SAS_TX_DP3 SAS_TX_DN3 A17 A18 GND GND B1 B2 SAS_RX_DP0 SAS_RX_DN0 B3 B4 GND SAS_RX_DP1 B5 B6 SAS_RX_DN1 GND B7 B8 SMB2_DATA3 GND B9 B10 SAS_SIO_DOUT_A SAS_SIO_DIN_A B1...

Страница 63: ... SCLOCK P3V3_AUX 9 10 HD_ERROR_LED PW2 Power Connector Definition Pin Pin Definition VDD_12V_RUN 1 2 GND GND 3 4 VDD_5V_RUN J7 Front Panel Connector Signal Pin Pin Signal TACH1 1 2 TACH6 TACH2 3 4 TACH7 TACH3 5 6 TACH8 TACH4 7 8 TACH9 TACH5 9 10 TACH10 GND 11 12 KEY PW2 13 14 PW1 TACH11 15 16 SDA TACH12 17 18 SCL VCC 19 20 PW3 ...

Страница 64: ...A14 B14 PEBp2 PEAp2 A15 B15 PEBp2 GND5 A16 B16 GND17 PEAn3 A17 B17 PEBp3 PEAn3 A18 B18 PEBp3 GND6 A19 B19 GND18 A20 A20 B20 B20 A21 A21 B21 B21 GND7 A22 B22 GND19 PEAn4 A23 B23 PEBp4 PEAn4 A24 B24 PEBp4 GND8 A25 B25 GND20 PEAn5 A26 B26 PEBp5 PEAn5 A27 B27 PEBp5 GND9 A28 B28 GND21 A29 A29 B29 B29 A30 A30 B30 B30 A31 A31 B31 B31 A32 A32 B32 B32 A33 A33 B33 B33 GND10 A34 B34 GND22 PEAp6 A35 B35 PEBp6...

Страница 65: ... Solid OFF Identify Locate the HDD Blinking 1Hz OFF Rebuild Blinking 4Hz OFF B8026G62FE10HR HDD Status ODn0 Act ODn1 Locate ODn2 Fail Activity LED Color Green Status LED Color Amber Drive not Present x x x OFF x Driver Present No Activity 0 x x ON x Activity 1or 4Hz x x OFF Blinking HDD Fail x 1 0 On Solid OFF Identify Locate the HDD x 1 0 x Blinking 1Hz Identify Locate the HDD x Blinking 2Hz 1 Re...

Страница 66: ...the Front Panel Board Follow these instructions to replace the M1716G75 FPB Front Panel Board 1 Unscrew the front panel tray 2 Pull the front panel tray forwards 4 Disconnect the control cable and USB3 0 cable from the front panel board ...

Страница 67: ...http www tyan com 67 5 Unscrew the front panel board from the front panel tray for a new one 6 Reinstall the Front Panel Board into the chassis following the steps in reverse ...

Страница 68: ...t Panel Board Features Front View Rear View Form Factor 28 x 35 4 x 1 6 mm 4 layer PCB Specifications I O 2 USB3 0 Port LED Indicators 1 HDD LED 1 Warning LED 2 LAN LED 1 Power ID LED Switch 1 Reset Button 1 ID Button 1 Power Button ...

Страница 69: ...cation Definition HDD_LED HDD LED BMC_EVENT_LED Warning LED LAN1_LED LAN1 LED LAN2_LED LAN2 LED ID_PW_LED Power ID LED J1 USB3 0 Port J2 USB3 0 Port J3 Reset Button J5 ID Button J6 Power Button J4 Front Panel Control Board Connector J7 USB3 0 Connector ...

Страница 70: ...wer Supply To replace the power supply follow these instructions 1 Located at the power supply usage 2 Free the power from the power socket 3 Replace a new power supply and reinsert it into the power socket following the above steps in reverse ...

Страница 71: ...fore you follow these instructions to replace the M1620G62F D PDB Power Distribution Board 1 Disconnect all the power cables 2 Unscrew to take off the power distribution board and replace with a new one 3 Follows the procedures described in reverse order to reinstall the power distribution board ...

Страница 72: ...M1620G62F D PDB 3 9 2 Connector Definitions M1620 Location Definition J2 J3 PWR1 PW2 PW5 PW3 PW4 PW1 DOM_5V_PW1 DOM_5V_PW2 Power Supply slot Power Supply slot ATX Power 12x2 ATX Power 4x2 ATX Power 4x2 HDD Power 4x1 HDD Power 4x1 PM Bus DOM Power DOM Power ...

Страница 73: ... PDB Redundant Control Board Form Factor 114 62mm L x 105 6mm W x 28mm H Specifications CON1 CON2 Input connector CON3 Mini fit 24 pin power connector CON4 CON5 HDD 4 pin power connector CON6 PMBus 5 pin CON7 CON8 Mini fit 8 pin ...

Страница 74: ...ON DC_GOOD S9 S10 A1 SMBus address 5Vsb S11 S12 5Vsb C_R S13 S14 SGND PRESENT A0 SMBus address S15 S16 B P SIG N A S17 S18 N A N A S19 S20 SGND B P FAIL S21 S22 N A 5Vsb S23 S24 5Vsb CON3 Mini fit 24 pin Output connector Pin assignment Definition Pin Pin Definition 3 3V 1 2 3 3V SGND 3 4 5V SGND 5 6 5V SGND 7 8 PWR OK 5Vsb 9 10 12V 12V 11 12 3 3V 3 3V 13 14 12V SGND 15 16 PS ON SGND 17 18 SGND SGN...

Страница 75: ... 8 PWR OK 5Vsb 9 10 12V 12V 11 12 3 3V 3 3V 13 14 12V SGND 15 16 PS ON SGND 17 18 SGND SGND 19 20 N A 5V 21 22 5V 5V 23 24 SGND CON6 PMBus 5 pin Definition Pin Pin Definition SCL 1 2 SDA SMBAlert 3 4 SGND N A 5 CON7 CON8 Mini fit 8 pin Definition Pin Pin Definition SGND 1 2 SGND SGND 3 4 SGND 12V 5 6 12V 12V 7 8 12V ...

Страница 76: ... of the aforementioned cables follow these instructions to remove the motherboard from the chassis 1 Disconnect SATA and USB cables For B8026G62FV10HR LE SKU 1 Disconnect NVMe Oculink Cable and USB cables For B8026G62FE10HR SKU 2 Disconnect the power cable and PSMI Cable ...

Страница 77: ... cable 3 11 Removing the Motherboard After removing all of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the nine screws securing the motherboard to the chassis 2 Carefully lift the motherboard from the chassis ...

Страница 78: ... to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are then stored in a dedicated battery backed memory called NVRAM that retains the information even when the power is turned off To start the BIOS setup utility 1 Turn on or reboot your system 2 Press F2...

Страница 79: ...seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 4 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic look and function of the BIOS setup remains more or less the same for most systems the appearance of your Setup screen may differ from the charts shown in this section Each system design and chipset...

Страница 80: ...s that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Product Name It displays Product information BIOS Version It displays BIOS version information Build Date and Time It displays the time when built Memory Information It displays the total memory size Memory Frequency It displays Memory frequency ...

Страница 81: ...m Date Set the Date Use Tab to switch between Date elements Default Ranges Year 2005 2099 Months 1 12 Days dependent on month System Time Adjust the system clock HH 24 hours format MM Minutes SS Seconds Access Level Adminstrator ...

Страница 82: ...U Configuration CPU Configuration parameters Onboard Device Configuration Onboard Device and Function Configuration PCIE Slot Configuraion Onboard PCIE Slot Configuration Trusted Computing Trusted Computing settings Hardware Health Configuration Hardware Health Configuration S5 RTC Wake Settings S5 RTC Wake Settings ...

Страница 83: ...ion SIO Configuration PCI Subsystem Settings PCI PCI X and PCI Express Settings CSM Configuration CSM Configuration Enable Disable Option ROM execution setting etc NVMe Configuration NVMe Device Options settings SATA Configuration SATA Device Information USB Configuration USB Configuration Parameters ...

Страница 84: ... tyan com 84 4 3 1 CPU Configuration SVM Mode Enable disable CPU virtulization Disabled Enabled SMEE Control secure memory encryption enable Disabled Enabled CPU 0 Information View Information related to CPU 0 ...

Страница 85: ...http www tyan com 85 4 3 1 1 CPU0 Information ...

Страница 86: ...ed Active Video Select between onboard or external VGA support Onboard Offboard Onboard LAN B5720 Enable Disable Onboard LAN Device Disabled Enabled LAN1 Port1 OPROM Enable Disable Load Option ROM For Onboard LAN Disabled Enabled LAN1 Port2 OPROM Enable Disable Load Option ROM For Onboard LAN Disabled Enabled ...

Страница 87: ...NMI Button Enable or disable NMI button Disabled Enabled Clock Spread Spectrum Enable Disable CG1_PLL Spread Spectrum Disabled Enabled Serial IRQ Mode Configure Serial IRQ Mode Quiet Continuous 4 3 3 PCIE Slot Configuration ...

Страница 88: ...dth Configuration Auto is detected by GPIO x8x8 x16 x4x4x4x4 x8x8 x16 Auto Riser L Down Slot Link Width Configution Setting Pcie Slot Link Width x4x4 x8 Riser R Middle Slot Link Width Configuration Right Riser Middle Slot Link Width Configuration x4x4x4x4 x8x8 x16 Auto Riser R Down Slot Link Width Configuration Setting Pcie Slot Link width x4x4 x8 OCP Slot OPROM Enable Disable Load Option ROM For ...

Страница 89: ...nk Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Riser L Middle Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Riser L Down Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Riser R Up Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s G...

Страница 90: ...ted Computing Security Device Support Enable or disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Enabled Disabled ...

Страница 91: ... www tyan com 91 4 3 5 Hardware Health Configuration Auto Fan Control Auto Fan Control help Disabled Enabled BMC Alert Beep Enable Disable BMC Alert Beep On Off PMBus support PMBus Support Disabled Enabled ...

Страница 92: ...m 92 4 3 5 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be modified Read only ...

Страница 93: ...http www tyan com 93 ...

Страница 94: ...ttings Wake system from S5 Enable or disable system wake on alarm event Select Fixed time system will wake on the hr min sec specified Select dynamic time system will wake on the current time increase minute s Disabled Fixed Time Dynamic Time ...

Страница 95: ...rial Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the host computer which the user is using will exchange data Both computers should have the same or compatible settings NOTE Console Redirection Settings menu only appear when Console Redirection was set...

Страница 96: ...erial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if the num of 1 s in the data bits is odd Mark parity bit is always...

Страница 97: ...t to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Disabled Enabled...

Страница 98: ...t VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes VT UTF8 VT100 VT100 ANSI Bits per Second Select serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 ...

Страница 99: ...ire more than 1 stop bit 1 2 Flow Control Flow Control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 C...

Страница 100: ... Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST when Bootloader is selected then Legacy Console Redirection is disabled before booting to legacy OS when Always Enable is selected then Legacy Console Redirection is enabled for Legacy OS Default setting for this option is set to Always Enable Always Enable BootLoader ...

Страница 101: ...er OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Settings page for more Help with Terminal Type Emulation VT UTF8 VT100 VT100 ANSI Bits per Second Select serial port transmission speed The speed must be matched on the other side Long or noisy lines may ...

Страница 102: ...hen sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS Data Bits Parity Stop Bits Read only ...

Страница 103: ...ve Serial Port 1 View and Set Basis properties of the SIO Logical device Like IO Base IRQ Range DMA Channel and Device Mode Active Serial Port 2 View and Set Basis properties of the SIO Logical device Like IO Base IRQ Range DMA Channel and Device Mode ...

Страница 104: ...nabled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 3 4 5 7 9 10 11 12 DMA IO 2F8h IRQ 3 4 5 7 9 10 11 12 DMA IO 3E8h IRQ 3 4 5 7 9 10 11 12 DMA IO 2E8h IRQ 3 4 5 7 9 10 11 12 DMA ...

Страница 105: ...nabled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 3 4 5 7 9 10 11 12 DMA IO 2F8h IRQ 3 4 5 7 9 10 11 12 DMA IO 3E8h IRQ 3 4 5 7 9 10 11 12 DMA IO 2E8h IRQ 3 4 5 7 9 10 11 12 DMA ...

Страница 106: ...evices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe devices this option Enable or Disable Single root IO virtualization Support Enabled Disabled PCI Express Settings Change PCI Express Devices Settings ...

Страница 107: ...http www tyan com 107 4 3 9 1 PCI Express Subsystem Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value Auto 128 Bytes 256 Bytes 512 Bytes ...

Страница 108: ...Network Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Storage Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Video Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Other PCI devices Determines OpRom execution policy for devices other than network storage or video Do not launch UEFI legacy ...

Страница 109: ...http www tyan com 109 4 3 11 NVMe Configuration ...

Страница 110: ...http www tyan com 110 4 3 12 SATA Configuration ...

Страница 111: ...nabled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support Enable Disable USB Mass Storage Driver Support Disabled Enabled Port 60 64 Emulation Enable I O port 60h 64h emulation support This should be enabled for the complete USB keyboard legacy support fo...

Страница 112: ...evice reset time out USB mass storage device Start Unit command time out 20 sec 10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller AUTO uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Auto Manual ...

Страница 113: ...w tyan com 113 4 4 Chipset Menu SMT Mode simultaneous multithreading OFF 1T single thread Auto 2T two thread if capable off Auto North Bridge North Bridge Parameters Error Management Error Management settings ...

Страница 114: ...http www tyan com 114 4 4 1 North Bridge Configuration Memory Configuration Memory Configuration Socket 0 Configuration View Information related to Socket 0 ...

Страница 115: ...http www tyan com 115 4 4 1 1 Memory Configuration Memory Clock This option Allows User to select different memory Clock Default value is 2400 MT s Auto 1333MHz 1600MHz 1866MHz 2133MHz 2400MHz 2667MHz ...

Страница 116: ...http www tyan com 116 4 4 1 2 Socket 0 Information ...

Страница 117: ...able PFEH cloak individual banks and mask deferred error interrupts from each bank Disabled Enabled NOTE The item Platform First Error Handling must be set up to Enabled the following item will appear MCA Error Threshold Count MCA Error Threshold Count 0 Disable Error 0 1 5 10 100 1000 ...

Страница 118: ...http www tyan com 118 4 5 AMD CBS Menu ...

Страница 119: ... Submenu Core Performance Boost Allows Core Performance Boost CPB to be forced to disabled Disabled Auto Global C state Control Controls IO based C state generation and DF C states Disabled Enabled Auto Core Thread Enablement Core Thread Enablement ...

Страница 120: ...http www tyan com 120 4 5 1 1 Core Thread Enablement Submenu ...

Страница 121: ...Submenu Downcore control Sets the number of cores to be used Once this option has been used to remove any cores a POWER CYCLE is required in order for future selections to take effect TWD 1 1 TWD 2 0 THREE 3 0 FOUR 2 2 FOUR 4 0 SIX 3 3 Auto ...

Страница 122: ...nterleaving Controls fabric level memory interleaving AUTO none channel die socket Note that channel die and socket has requirements on memory populations and it will be ignored if the memory doesn t support the selected option None Channel Die Socket Auto Memory interleaving size Controls the memory interleaving size The valid value are AUTO 256 bytes 512 bytes 1 Kbytes or 2Kbytes This determines...

Страница 123: ...http www tyan com 123 4 5 3 UMC Common Options Submenu ...

Страница 124: ...http www tyan com 124 4 5 3 1 DDR4 Common Options Submenu ...

Страница 125: ... www tyan com 125 4 5 3 1 1 Common RAS Options Submenu Data Poisoning Enable disable data poisoning UMC_CH EccCtrl UcFatalEn UMC_CH EccCtrl WrEccEn Should be enabled disabled together Disabled Enabled Auto ...

Страница 126: ... 1 1 1 ECC Configuration Submenu DRAM ECC Symbol Size DRAM ECC Symbol Size x4 x8 UMC_CH EccCtrl EccSymbolSize X4 x8 Auto DRAM ECC Enable Use this option to enable disable DRAM ECC Auto will set ECC to enable Disabled Enabled Auto ...

Страница 127: ...http www tyan com 127 4 5 3 2 Security Submenu Data Scramble Data scrambling DataScrambleEn Enabled Disabled Auto ...

Страница 128: ...g Submenu Chipselect Interleaving Interleave memory blocks across the DRAM chip selects for node 0 Disabled Auto BankGroupSwap This is an advanced performance setting specifies if the system should use DRAM Bank Group Swap mode Enabled Disabled Auto ...

Страница 129: ...eterminism settings power performance Auto Power Perfomance cTDP Control Auto Use the fused cTDP Manual User can set customized cTDP Manual Auto ACS Enable Supported functions of Access Control Services Enable Disabled Auto PCIe ARI Support Enables Alternative Routing IO Interpretation Disable Enable Auto ...

Страница 130: ...http www tyan com 130 4 5 4 1 NB Configuration Submenu IOMMU Enable Disable IOMMU Disabled Enabled Auto ...

Страница 131: ...http www tyan com 131 4 5 4 FCH Common Options Submenu ...

Страница 132: ...http www tyan com 132 4 5 4 1 Ac Power Loss Options Submenu Restore Ac Power Loss Select Ac Loss Control Method Power Off Power On Last State ...

Страница 133: ...imer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FBR 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing Reset Power Down Power Cycle OS Watchdog Timer If enabled starts a BIOS timer which can only be shut off by management Software after the OS loads Helps determine that the OS successfully loaded or fo...

Страница 134: ...isabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled Do Nothing Reset Power Down Power Cycle BMC Logo Enable or Disable BMC logo Disabled Enabled System Event Log Press Enter to change the SEL event log configuration BMC network configuration Configure...

Страница 135: ...g boot Enabled Disabled Erase SEL Choose options for erasing SEL No Yes on next reset No on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Log EFI Status Codes Disable the logging of EFI Status Codes or log only error code or only progress code or both Both Disabled Error Code Progress Code ...

Страница 136: ...http www tyan com 136 4 6 2 BMC Network Configuration Submenu ...

Страница 137: ...ny BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Configure IPV4 support Management Port 2 Enable Disable BMC Share NIC Disabled Enabled Configure IPV6 support Management Port 1 IPV6 Support Enable or Disable LAN1 IPV6 Support Disabled Enabled Management Port 2 IPV6 Support Enable or Disable LAN2 IPV6 Support Disabled Enabled ...

Страница 138: ...strator Password Set Administrator Password User Password Set User Password Security Frozen Mode Enable or disable HDD security freeze lock Disable to support secure erase function Disabled Enabled Secure Boot Customizable Secure Boot settings ...

Страница 139: ...nrolled System mode is User Deployed and CSM function is disabled Enabled Disabled Secure Boot Mode Secure Boot mode selector Custom mode enables users to change Image execution policy and manage secure boot keys Standard Custom Key Management Enables expert users to modify Secure Boot Policy variables without full authentication ...

Страница 140: ...to User Mode install all Factory Default keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 hash of the binary into Autorized Signature Database db Platform Key PK Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Vari...

Страница 141: ...Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test Forbidden Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SH...

Страница 142: ...lt External Mixed Test OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test ...

Страница 143: ...5 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enabled or Disabled Endless boot Disabled Enabled Wait for ESC if Error Wait for ESC stop when BIOS has error appeared Disabled Enabled ...

Страница 144: ...http www tyan com 144 Boot Option Priorities Boot Option 1 Sets the system boot order Device Name Disabled Delete Boot Option Remove an EFI boot option from the boot order ...

Страница 145: ...http www tyan com 145 4 8 1 Delete Boot Option Configuration Delete Boot Option Sets the system boot order Device Name Select one to Delete ...

Страница 146: ...xit Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes done so far to any of the setup options ...

Страница 147: ... Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Device Name ...

Страница 148: ...he motherboard A table of BIOS Temp sensor name explanation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan speed rpm 2 Temp Sensor SYS_Air_Outlet and MB_Air_Inlet etc They detect the system temperature around ...

Страница 149: ...http www tyan com 149 NOTE The system temperature is measured in a scale defined by AMD not in Fahrenheit or Celsius BIOS Temp Sensor Name Explanation ...

Страница 150: ...ghest temperature of CPU0 D1UMC0 channel A slot P0_D1_UMC1_CH_B The highest temperature of CPU0 D1 UMC1 channel B slot P0_D0_UMC1_CH_C The highest temperature of CPU0 D0 UMC1 channel C slot P0_D0_UMC0_CH_D The highest temperature of CPU0 D0 UMC0 channel D slot P0_D3_UMC0_CH_E The highest temperature of CPU0 D3 UMC0 channel E slot P0_D3_UMC1_CH_F The highest temperature of CPU0 D3 UMC1 channel F sl...

Страница 151: ...N_4 Fan speed of SYS_FAN_4 SYS_FAN_5 Fan speed of SYS_FAN_5 SYS_FAN_6 Fan speed of SYS_FAN_6 SYS_FAN_7 Fan speed of SYS_FAN_7 SYS_FAN_8 Fan speed of SYS_FAN_8 SYS_FAN_9 Fan speed of SYS_FAN_9 SYS_FAN_10 Fan speed of SYS_FAN_10 SYS_FAN_11 Fan speed of SYS_FAN_11 SYS_FAN_12 Fan speed of SYS_FAN_12 ...

Страница 152: ...to install the IO Plate for OCP Card Here shows how to install the IO Plate for the dual port LAN card M7106 X557 2T2E 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis 3 Use a screwdriver to break the semi shearing for the OCP card slot Discharge the metal slug ...

Страница 153: ...out the IO plate for LAN card Use a screwdriver to break the LAN port s semi shearing Break one semi shearing if a single port LAN card is installed Break both for a dual port LAN card 5 Insert the IO Plate to the OCP card LAN port ...

Страница 154: ...http www tyan com 154 7 Insert the LAN card into the OCP slot ...

Страница 155: ...http www tyan com 155 8 Secure the LAN card to the chassis ...

Страница 156: ...an4 FAN5 2 FP Control Cable and USB Cable M1716G75 FPB Control Board to S8026 MB M1716G75 FPB Connect to S8026 FP Ctrl Cable J4 FPIO_1 USB Cable J7 USB3_FPIO1 3 OCulink Cable SATA Cable FAN Ctrl Cable FOR B8026G62FV10HR LE M1274 Backplane BP Board to S8026 MB Cable M1274G62B BP1 2 10 B8026 Connect to S8026GM2NR LE OCulink Cable TO MINI SAS SATA0_3 SATA4_7 OCUL1 SATA Cable SATA8 SATA9 SATADOM1 SATA...

Страница 157: ...9 FAN_HD1 SATA Cable SATA8 SATA9 SATADOM1 SATADOM2 4 Power Cables TD15 0128 02 PDB to S8026 MB TD15 0128 02 Connect to S8026 2x12P Cable CON3 PW1 2x4P Cable CON7 PW3 PSMI Cable CON6 PSMI1 TD15 0128 02 PDB to M1274 Backplane BP Board TD15 0128 02 Connect to M1274G62B BP12 10 B8026 B4P Cable CON5 PW1 B4P Cable CON4 PW2 TD15 0128 02 PDB to M1286 Backplane BP Board TD15 0128 02 Connect to M1286G62F BP...

Страница 158: ...ts FRU AS 0020 452T15200002 Slide Rail Kit Cable FRU CS 0681 422T57100007 Oculink to Mini SAS Cable 700mm B8026G62FV10HR LE SKU FRU CS 0791 422T57100006 Oculink to Oculink Cable Reversed Signal 600mm B8026G62FE10HR SKU FRU CS 0781 422T57100005 Oculink to Oculink Cable 600mm B8026G62FE10HR SKU FRU CS 0330 332810000514 A C Power Cord L 1800mm US type CCBL 0300 332810000281 A C Power Cord L 1830mm EU...

Страница 159: ...http www tyan com 159 NOTE ...

Страница 160: ...r expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find their latest software and operating system components to keep their systems runni...

Страница 161: ...roper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufacturer for a Return Merchandise Authorization RMA number The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid TYAN will pay t...

Отзывы: