http://www.tyan.com
122
4.5.2 DF Common Options Submenu
DRAM scrub time
Provide a value that is the number of hours to scrub memory.
Disabled / 1 hour / 4 hours / 8 hours / 16 hours / 24 hours / 48 hours /
Auto
Redirect scrubber control
Control DF::RedirScrubCtrl [EnRedirScrub]
Disabled / Enabled /
Auto
Memory interleaving
Controls fabric level memory interleaving (AUTO, none, channel, die, socket). Note
that channel, die, and socket has requirements on memory populations and it will be
ignored if the memory doesn
’t support the selected option.
None / Channel / Die / Socket /
Auto
Memory interleaving size
Controls the memory interleaving size. The valid value are AUTO, 256 bytes, 512
bytes, 1 Kbytes or 2Kbytes. This determines the starting address of the interleave
(bit 8,9,10 or 11).
256 Bytes / 512 Bytes / 1 KB / 2 KB /
Auto
Содержание TYAN B8026G62FE10HR
Страница 1: ...GT62F B8026 Service Engineer s Manual ...
Страница 27: ...1 3 4 Internal View B8026G62FE10HR B8026G62FV10HR LE ...
Страница 32: ...2 1 2 Removing the Air Duct 1 Remove the air duct from the chassis ...
Страница 37: ...DIMM Location ...
Страница 42: ...4 Insert the PCI E card in the direction of arrows as shown ...
Страница 43: ...5 Screw the PCI E cards firmly to the riser card bracket ...
Страница 48: ...http www tyan com 48 3 Secure the mounting ears of chassis to the rack with 2 M5 15L C screws ...
Страница 52: ...http www tyan com 52 3 4 1 Riser Card Features M7106 L16 1F Riser Card M7106 R16 1F Riser Card ...
Страница 55: ...http www tyan com 55 7 Remove the eight screws securing the bracket to the HDD backplane ...
Страница 85: ...http www tyan com 85 4 3 1 1 CPU0 Information ...
Страница 93: ...http www tyan com 93 ...
Страница 109: ...http www tyan com 109 4 3 11 NVMe Configuration ...
Страница 110: ...http www tyan com 110 4 3 12 SATA Configuration ...
Страница 116: ...http www tyan com 116 4 4 1 2 Socket 0 Information ...
Страница 118: ...http www tyan com 118 4 5 AMD CBS Menu ...
Страница 120: ...http www tyan com 120 4 5 1 1 Core Thread Enablement Submenu ...
Страница 123: ...http www tyan com 123 4 5 3 UMC Common Options Submenu ...
Страница 124: ...http www tyan com 124 4 5 3 1 DDR4 Common Options Submenu ...
Страница 127: ...http www tyan com 127 4 5 3 2 Security Submenu Data Scramble Data scrambling DataScrambleEn Enabled Disabled Auto ...
Страница 130: ...http www tyan com 130 4 5 4 1 NB Configuration Submenu IOMMU Enable Disable IOMMU Disabled Enabled Auto ...
Страница 131: ...http www tyan com 131 4 5 4 FCH Common Options Submenu ...
Страница 136: ...http www tyan com 136 4 6 2 BMC Network Configuration Submenu ...
Страница 154: ...http www tyan com 154 7 Insert the LAN card into the OCP slot ...
Страница 155: ...http www tyan com 155 8 Secure the LAN card to the chassis ...
Страница 159: ...http www tyan com 159 NOTE ...