background image

• On firm level surface.
• Free from flooding or sprinklers.
• Near GFCI outlet and faucet.

1.

Position Gen III+ Unit

• Confirm faucet is able to deliver at 

least 1 gal/min..

• Be careful not to introduce dirt or 

other contaminants into line.

• Insert 3/8” tubing/filter assembly into 

3/8” bulkhead fitting located at the 
back right corner of unit.

• Thread adapter onto faucet (or 

optional hose bib “Y”).

• Measure and cut 3/8” nylon tubing
• Run water to flush line before 

connecting to filter inlet.

2.

Install Water Supply 
Line

3.

Connect Nozzle 
Circuit

• To ¼” bulkhead fitting at back right 

corner of unit.

• If zone kit, install according to 

instructions provided.

Section 3

Setting Up the Unit

• SET-UP Menu, ALT.
• If sensor installed, set 

time (in seconds) that 
alarm will sound prior to 
each scheduled and 
remote mist.

j.

Establish 
optional 
External Alarm

• CYCLES Menu.
• 2 – 3 scheduled mists of 30 – 60 

seconds in duration is common. 

• See Section 5, Managing Insecticide 

for field standard frequency, duration 
and mist times.

• Blinking C# identifies each 

automatic mist cycle with current 
mist duration and mist time.  Limit is 
24 cycles per day.

• Set mist duration and time (note 

a.

Set AUTO 
MIST Cycles

9.

Set Misting Schedule

Section 3

Setting Up the Unit

• GFCI Outlet.
• 115 volts minimum.  Confirm voltage 

with multi-meter.

• 15 amp circuit required.  Unit draws 

9 amps when misting.  Ensure total 
load of unit plus all other devices on 
circuit does not exceed breaker 
rating.

5.

Connect Electric 
Power

instructions provided.

4.

Connect Remote 
Antenna

• Thread onto coax fitting on top of 

unit.

• MAINTENANCE Menu, scroll to INS.
• Depress Green 

button 5 seconds

• Unit will fill and mist for 5 minutes or 

until stopped.

• Confirm pump pressure (240 psi) 

and insert plastic plug into pump 
adjustment port. 

• Confirm no leaks in nozzle circuit
• If zone valve installed, repeat for 

INS2.

6.

Run Inspection 
Cycle

• Set mist duration and time (note 

AM/PM) for each desired scheduled 
mist.

• MAINTENANCE Menu, scroll to 

CHG.

• Depress Green 

button 5 seconds.

• DOSE will flash for extended period 

as batch tank of fresh water is 
brought to target concentration.

10. Charge Insecticide

• If you don’t want to schedule mists 

for every day.

• CUSTOM PGM Menu.
• Set selected days to ON or OFF.
• System Mode must be set to AUTO 

Custom.

b. Set AUTO MIST 

Days