Javelin I & II Power Supply Operator’s Manual

 

Javelin I & II Power Supply 

Power Factor Corrected AC-DC Switcher 

Javelin I & II Power Supply “Quick Install” Instructions

 

 

   The Javelin can be mounted at either of two sides (top or bottom). 

 

   Use #8-32 mounting screws.  Maximum penetration should not exceed 0.21″ (5,33mm). 

 

   Maintain 2″ (50,8mm) clearance at either end for airflow. 

 

Input AC or DC power is applied to connector J1 using a 3W3 Power 
Connector (Table 1). 

 

To connect, use ITT/Cannon mating receptacle P/N DAM3W3SA197 
with pins, P/N DM53744-6. 

 

A fault-clearing device, such as a fuse or circuit breaker, with  
maximum 15A rating at the power supply input is required for 
safety agency compliance. 

Single Phase 

DC 

 A1         L1 

 A1        + 

 A2         L2/N 

 A2         – 

 A3         Earth Gnd 

 A3        Earth Gnd 

Table 1.  AC and DC Input Connections 

Status/Control Connector (J2) 

 

J2-1 and J2-9 are spare pins and are not used. 

 

J2-2 and J2-4 are Signal Return pins. 

 

J2-3 is +12V fan power. 

 

J2-5 is VCC +5V @ 300mA. 

 

J2-6 is AC Power OK (+5V = true). 

 

J2-7 and J2-8 are used in conjunction according to the following table: 

Input Connections 

Input Connector (J1) 

Mounting the Javelin Power Supply 

J2-8 

INHIBIT′ 

J2-7 

ENABLE′ 

POWER SUPPLY 

STATE 

ON 

ON 

OFF 

Table 2. Inhibit/Enable Logic Table

 

 

Use ITT/Cannon mating connector P/N DE9PK87 with Amp cover 
shell P/N 205729-1. 

 

Use 20-24 AWG stranded wire. 

Rev. 05/11/2012    Mission Power Solutions        (760) 631-6846          [email protected]             Pg. 2

 

J2 Interface Pin Out 

J2-1 

Spare 

J2-2   Signal Return 
J2-3 

Fan Power 

J2-4 

Signal Return 

J2-5 

VCC +5V @ 300mA 

J2-6 

AC Power OK 

J2-7 

PS Enable 

J2-8 

PS Inhibit 

J2-9 

Spare 

A1     A2     A3 

Содержание Javelin I

Страница 1: ...Supply Operator s Manual I II Power Supply Power Factor Corrected AC DC Switcher Operator s Manual and Quick Install Instructions www mpwrs com Rev 05 11 2012 Mission Power Solutions 760 631 6846 sal...

Страница 2: ...e Phase DC A1 L1 A1 A2 L2 N A2 A3 Earth Gnd A3 Earth Gnd Table 1 AC and DC Input Connections Status Control Connector J2 J2 1 and J2 9 are spare pins and are not used J2 2 and J2 4 are Signal Return p...

Страница 3: ...sitive load con nection and pin J3 6 to the negative load connection Attach load end of sense lines at the point where regulation is desired J3 2 and J3 8 provide DC OK and DC OK signals J3 3 and J3 7...

Страница 4: ...ith Auto Sense Output overcurrent overvoltage and overtemperature protection Ride through holdup time 20 ms at 1200W load Size 4 9 H x 7 0 W x 10 75 L 9 5 L for Javelin II Heavy duty ruggedized enclos...

Страница 5: ...power output to come up 15 30 ms later An auxiliary Vcc output of 5 VDC capable of sourcing up to 300mA is provided for peripheral use An output Inhibit Enable function is provided by using an optocou...

Страница 6: ...ame as Earth Ground on input power connector J1 Inhibit Enable J2 7 to J2 8 The Inhibit Enable control pins allow the output to be controlled with either inhibit or enable logic Con necting Inhibit J2...

Страница 7: ...voltage drop along the output power cables the output can be trimmed up or configured for Remote Sense Use stranded twisted pair 20 24 AWG wire for the Remote Sense lines Remote Sense can compensate f...

Страница 8: ...nals i e a fuse Use proper size wires to avoid overheating and excessive voltage drop Do not attempt to repair or modify the power supply in any manner Do not restrict airflow to the unit The cooling...

Страница 9: ...Javelin I II Power Supply Operator s Manual Mechanical Drawing Javelin I Rev 05 11 2012 Mission Power Solutions 760 631 6846 sales mpwrs com Pg 9...

Страница 10: ...Javelin I II Power Supply Operator s Manual Mechanical Drawing Javelin II page 1 Rev 05 11 2012 Mission Power Solutions 760 631 6846 sales mpwrs com Pg 10...

Страница 11: ...Javelin I II Power Supply Operator s Manual Mechanical Drawing Javelin II page 2 Rev 05 11 2012 Mission Power Solutions 760 631 6846 sales mpwrs com Pg 11...

Страница 12: ...W load Transient Surge IEC 801 5 level 3 Common Mode Normal Mode Dielectric Withstand Primary to Chassis GND 2121 VDC Primary to Secondary 4242 VDC Secondary to Chassis GND 500 VDC Output Parameter MI...

Страница 13: ...ower 55 C to 55 C M Grade Half Power 55 C to 70 C Product Weight 11 50 lbs 11 0 lbs Javelin II Dimensions 4 9 H 124 46mm x 7 0 W 177 8mm x 10 75 L 273 1mm 9 5 L 241 3mm for Javelin II Warranty 1 Year...

Страница 14: ...00 1200 1400 1600 1800 2000 0 20 40 60 80 100 Pout max Temperature Ambient C Maximum Output Power vs Temperature 400W 600W 800W 1200W 1600W 1800W Rev 05 11 2012 Mission Power Solutions 760 631 6846 sa...