Javelin I & II Power Supply Operator’s Manual
Environmental
MIL-STD
810E
Storage Temperature
C Grade
40
C to
125
C
T Grade
40
C to
125
C
H Grade
55
C to
125
C
M Grade
65
C to +125
C
Operating Temperature
C Grade, Full Power
20
C to +55
C
C Grade, Half Power
20
C to +70
C
T Grade, Full Power
40
C to
55
C
T Grade, Half Power
40
C to
70
C
H Grade, Full Power
40
C to
55
C
H Grade, Half Power
40
C to
70
C
M Grade, Full Power
55
C to
55
C
M Grade, Half Power
55
C to
70
C
Product Weight
11.50 lbs. (11.0 lbs. Javelin II)
Dimensions
4.9
H (124,46mm) x 7.0
W (177,8mm) x 10.75
L (273,1mm)
[9.5
L (241,3mm) for Javelin II]
Warranty
1 Year Limited
Rev. 05/11/2012 Mission Power Solutions (760) 631-6846 [email protected] Pg. 13
INPUT POWER
RATING MAXIMUM INPUT TYPE (#)
INPUT VOLTAGE RANGE
(WATTS)
Vout >10 / Vout<10
1
600
(1) SINGLE PHASE 80 / 85 TO 254 VAC
(2) DIRECT CURRENT80 / 85 TO 380 VDC
2
800
(1) SINGLE PHASE 102 / 108 TO 254 VAC
(2) DIRECT CURRENT102 / 108 TO 380 VDC
3
1200 (1) SINGLE PHASE 146 / 158 TO 254 VAC
(2) DIRECT CURRENT146 / 158 TO 380 VDC
4
1600 (1) SINGLE PHASE 192 TO 254 VAC
(2) DIRECT CURRENT192 TO 380 VDC
5
1800 (1) SINGLE PHASE 215 TO 254 VAC
(2) DIRECT CURRENT215 TO 380 VDC
Maximum Output Power vs. Input Voltage AC or DC
0
200
400
600
800
1000
1200
1400
1600
1800
2000
50
100
150
200
250
Minimum Input Voltage AC or DC
M
a
x
im
u
m
O
u
tp
u
t P
o
w
e
r
Output Voltages > 10Vdc
Output Voltages <10 Vdc
Maximum Output Power vs. Temperature
0
200
400
600
800
1000
1200
1400
1600
1800
2000
0
20
40
60
80
100
TA max
P
ou
t m
ax
400W
600W
800W
1200W
1600W
1800W
Graph 1. Maximum Output Power vs. Input Voltage