background image

Troubleshooting

15

TROUBLESHOOTING PROCEDURES

Issue

Cause

What to do

After installation, 

the unit doesn’t 

work.

1.  The power source is not turned ON.

1.  Make sure the circuit breaker and the unit’s 

power is ON.

2.  The power line and the cable locking connector 

is not connecting properly.

2.  Check the power connection with the unit is 

connected properly.

3.  The switch board and control board wirings are 

disconnected.

3.  Make sure the wirings between the switch 

board and control board are connected 

properly.

4.  On the switch board, Black/White wire or White 

wire is disconnected.

4.  Make sure the Black/White wire or White wire 

connects properly.

5.  The switch board or control board is defective.

5.  Change the switch board or control board.

Light works, 

but motor is not 

turning.

1.  The blower is defective, possible seized.

1.  Change the blower.

2.  The thermally protected system detects if the 

motor is too hot to operate and shuts the motor 

down.

2.  The motor will function properly after the 

thermally protected system cool down.

3.  Damaged capacitor.

3.  Change the capacitor.

The unit is 

vibrating.

1.  The blower is not secure in place.

1.  Tighten the blower in place.

2.  Damaged blower wheel.

2.  Change the blower.

3.  The hood is not secured in place.

3.  Check the installation of the hood.

The motor is 

working, but the 

lights are not.

1.  Defective halogen bulb.

1.  Change the halogen bulb.

2.  The light bulb is loose.

2.  Tighten the light bulb.

The hood is 

not venting out 

properly.

1.  The hood might be hanging to high from the 

cook top.

1.  Adjust the distance between the cook top and 

the bottom of the hood within 26” to 34” range.

2.  The wind from the opened windows or opened 

doors in the surrounding area are affecting the 

ventilation of the hood.

2.  Close all the windows and doors to eliminate 

the outside wind flow.

3.  Blocking in the duct opening or duct work.

3.  Remove all the blocking from the duct work or 

duct opening.

4.  The direction of duct opening is against the wind. 4.  Adjust the duct opening direction.
5.  Using the wrong size of ducting.

5.  Change the ducting to at least 6” or higher.

Metal filter is 

vibrating.

1.  Metal filter is loose.

1.  Change the metal filter.

2.  Spring clip is broken.

2.  Change the spring clip.

Содержание MH80120AS

Страница 1: ...Installation Use and Care Guide READ AND SAVE THESE INSTRUCTIONS 2017 APR READ AND SAVE THESE INSTRUCTIONS MH80120AS MODEL ...

Страница 2: ......

Страница 3: ...Height Clearance 6 Ducting Options 7 Specifications 8 Electrical 9 Installing the Power Pack 10 FEATURES CONTROLS Slide Controls 11 MAINTENANCE Cleaning and Installing Filters 12 Recirculating Kit 13 Lights 14 TROUBLESHOOTING 15 LIST OF PARTS AND ACCESSORIES 16 WARRANTY 17 Table of Contents ...

Страница 4: ... of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT US...

Страница 5: ...e Do not ground to a gas pipe Check with a qualified electrician if you are not sure the range hood is properly grounded Do not have a fuse in the neutral or ground circuit National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 This appliance requires a 120V 60Hz electrical supply and connected to...

Страница 6: ...e installed 1 Single internal blower pre installed 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Optional stainless steel liner AK084xAS Optional Recirculating Kit ZRC 8400A Suction Cup 1 M4 x 1 4 M4 x 1 1 2 4 ...

Страница 7: ...10 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 roundto 3 1 4 x 10 rect transition 900 elbow 16 Ft x Ft 7 roundto 3 1 4 x 10 rect transition 8 Ft x Ft 7 roundto 3 1 4 x 10 rect transition 900 elbow 23 Ft x Ft ...

Страница 8: ...d be no higher than 34 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose its performance and efficiency If available also refer range manufacturer s height clearance requirements and recommended hood mounting height above range Vertical Ducting 6 round ...

Страница 9: ...ll exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ...

Страница 10: ...8 Installation Specifications top bottom side 20 9 16 10 5 8 3 1 4 1 5 16 19 1 2 12 1 8 11 4 6 5 1 16 1 5 8 14 3 16 1 15 16 6 7 16 16 9 16 9 15 16 1 3 16 9 11 16 11 3 16 front ...

Страница 11: ... circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Grounding This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an excape wire for the electrical current This appliance is equipped with a cord having a grounding wire with a grounding plug The pl...

Страница 12: ...s from Power Pack face plate The face plate will drop down and hang by internal chains Access to front long side of Power Pack is now available Fasten 2 M4 screws into the front long side of Power Pack 7 Re install Power Pack face plate by 4 previously removed screws 8 Install duct work and seal with duct tape 9 Install electrical 10 Remove all packing materials before using Power Pack Switch powe...

Страница 13: ...ed Selection 1 Lights Bright Dim Off 2 0 I I I Features Controls Slide Controls BLOWER ON OFF SPEED SELECTION 0 is off I is low speed II is medium speed and III is high speed LIGHTS BRIGHT DIM OFF 0 is off I is dim and II is bright 1 2 ...

Страница 14: ...sh cleaners to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth or micro fiber cloth and buff in the direction of the stainless steel grain Aluminum Mesh Filters The aluminum mesh filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Re...

Страница 15: ... top of the standard metal mesh filter and a return air vent is needed to direct air back into the kitchen The standard metal mesh filter is intended to capture residue from cooking and the optional charcoal filter helps to purify fumes exhausted from cooking in recirculating mode Purchase recirculating kit as follows Hood Model Part No Qty to Order MH80120AS ZRC 8400A 1 Charcoal filters must be r...

Страница 16: ...ulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type MR16 GU 10 35W halogen For part numbers please turn to p...

Страница 17: ...otected system cool down 3 Damaged capacitor 3 Change the capacitor The unit is vibrating 1 The blower is not secure in place 1 Tighten the blower in place 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The light bulb is loose 2 Tighte...

Страница 18: ...Z0B 0023 Aluminum Mesh Filter each 50200054 Charcoal Filter each Z0F C084 Optional Accessories Liner 30 AK0840AS Liner 36 AK0846AS Recirculating Kit ZRC 8400A Light Bulb MR16 GU 10 LED each Z0B 0040 To order parts call us at 1 888 750 1698 List of Parts and Accessories ...

Страница 19: ...rchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECED...

Отзывы: