Installation and operating instructions
CHIMNEY
Main component: 15125R
Extension parts: 15200R, 15225R, 15325R
The Misa system chimney has been tested and marked for use in accordance with the EN
1856-1:2009 standard in fireplaces with the maximum continuous flue-gas temperature of
+600°C.
The clearance requirement from flammable structures is 50 mm.
The product is CE marked. The area code of the chimney is:
EN 1856-1 – T600 – N1 – D – Vm – L20100 – G50
Explanations:
-
T600:
the allowed maximum continuous flue-gas temperature is +600°C
-
N1:
density classification
-
D:
fireplaces that use solid fuel, such as wood-burning sauna stoves
-
Vm:
corrosion durability
-
L20100:
the material of the flue pipe stainless steel EN 1.4301, thickness 1 mm
-
G50:
resistant to chimney fires, clearance requirement from flammable structures 50 mm
Structure of the chimney:
In addition, sheeting for both the roof and the ceiling is provided with the main component 15125R.