Dry Wall
Stud W
all
Tub Flange
13”
13”
6”
MODEL
BELAIRE SECTIONAL BA54L/R - DOME LESS TUB SHOWER
INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL
READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
PLEASE RECORD THE SERIAL NUMBER _________ OF YOUR TUB SHOWER AND SAVE THIS
MANUAL FOR FUTURE REFERENCE
1
FIGURE 1 -
LAYOUT DIMENSIONS
FIGURE 2 -
SHOWING THE TOP VIEW OF THE
SHOWER IN THE ALCOVE.
HELP LINE INFO:
1-800-MIROLIN.
VISIT
www.mirolin.com
FOR INFORMATION CALL:
TOLL FREE
TOOLS AND MATERIALS REQUIRED
CAUTION:
Tools:
Materials:
Tape Measure, Electric Drill, Drill Bit (3/16”), Level, Hole
Saw and Caulking Gun
Mildew Resistant Silicone Bathroom Caulking,
Drywall Screws and Shims (if required).
To cut plumbing fixture openings on the tub shower unit:
Use correct size hole saw based on selected fixture design.
Cut from the finished side of the unit.
Use masking tape to mask the surrounding surface to
prevent scratches and other damages.
"
"
"
Important:
General Installation Notes
Shimming May Be Required
The Acrylic Tub Shower is carefully inspected and
packed for shipment. You should check your unit and if there are
any problems, contact your dealer before installation.
For whirlpool models refer to Whirlpool Owner’s Manual for
additional Installation and Operating Instructions.
For Jet Air models refer to Jet Air Owner’s Manual.
The Tub Shower is to fit into framed alcove as shown in
Figure 1 and Figure 2.
.
Framing:
Inside dimension of the studded alcove are to be as
specified in Figure 1.
The unit will rest on the front edge and the two legs at the
rear and one leg in the centre of the bathing well. Shims may
be required to level the tub to ensure adequate drainage.
The shower is fastened in place using dry wall screws. Holes
are to be drilled in the flange on both sides and across the
top. The holes are to be drilled by the installer as illustrated
in figures 3 - 6 on the following pages.
Protect the tub and walls from dirt and damage by leaving
the polyethylene protective film in place until installation
and other related construction are complete.
Follow Local Building Codes.
Note: Dimensions are for framed openings. Refer to
specification sheet for specific product dimensions.
”
!
!
!
!
!
Rough-in dimensions are 80” x 60 1/4
©
Copyright 2010
The Copyright includes all content on the document.
Mirolin Ind.
33
½”
6”
22”
80”
34 ½
”
FOR
WHIRLPOOL
13
”
60 1/4”
16 1/8
”
17 1/8
”
FOR
WHIRLPOOL
7 3/8”
STUD
LOCA
TION
STUD