background image

Canada
25 Interchange Way
Vaughan, ON L4K 5W3
Tel: 905-660-4655 Fax: 905-660-4113

©

 Mircom 2003

Printed in Canada
Subject to change without prior notice

www.mircom.com

TAS-2000 SERIES

NSL Telephone Access System

LT-956 Rev. 0
April 2005

User Guide

Advanced Life Safety Solutions

Advanced Life Safety Solutions

RELAY CABINET No. __
DECODER/MOTHER BOARD No. __

RELAY/LINE

NUMBER

RELAY CARD

NUMBER

8

7

6

5

4

3

2

1

_____ to _____

_____ to _____

_____ to _____

_____ to _____

_____ to _____

_____ to _____

_____ to _____

_____ to _____

3

5

4

7

9

0

8

U.S.A.
60 Industrial Parkway
Cheektowaga, NY 14227
Tel: 1-888-660-4655 Fax: 1-888-660-4113

Содержание TAS-2000 Series

Страница 1: ...6 Rev 0 April 2005 User Guide Advanced Life Safety Solutions Advanced Life Safety Solutions RELAY CABINET No __ DECODER MOTHER BOARD No __ RELAY LINE NUMBER RELAY CARD NUMBER 8 7 6 5 4 3 2 1 _____ to...

Страница 2: ......

Страница 3: ...ds 6 Editing Records 8 Deleting Records 10 Setting Main and Aux Door DTMF 11 Setting the Online and Door Timers 12 Changing Your Password 13 Part 2 Scrolling Directory Programming Entering Names 16 Pr...

Страница 4: ...ii...

Страница 5: ...display screen The easiest way to determine if you have a non scrolling directory is to look at the screen on your TAS 2000 when it is in normal mode The display should look like this If your screen l...

Страница 6: ...ure you have filled out the Resident Directory Worksheet on page 29 Entering Programming mode 1 Press 2 Enter the password If you have not set a personal password press ten digit factory default If yo...

Страница 7: ...e you must first be in the programming menu If you are not in the programming menu use the keypad navigation diagram to exit from the mode you are currently in Exiting Programming Mode 1 Press to scro...

Страница 8: ...Introduction 4...

Страница 9: ...5 Part 1 Non Scrolling Directory Programming...

Страница 10: ...Relay Code 1 Enter the relay code 2 Press to save and continue Step 4 Enter NSL ID 1 Enter the NSL ID 2 Press to save and continue Step 5 Enter Elevator Code If elevator control is not being used pres...

Страница 11: ...ough 8 Step 7 Enter Keyless Code If keyless codes are being used enter the 4 digit code Press to save and continue If keyless codes are not being used press to save and continue Step 8 Enter Ring Patt...

Страница 12: ...te Records are listed according to resident dial code Step 3 Enter Dial Code If you want to change the dial code enter a code that is between 1 to 4 digits long Press to save and continue If you do no...

Страница 13: ...eing used please contact your technician for assistance Step 8 Enter Keyless Code If keyless codes are being used enter the 4 digit code Press to save and continue If keyless codes are not being used...

Страница 14: ...p 2 To exit Delete Record mode press to return to the programming menu Step 1 Enter Delete Record mode 1 Press scroll up or scroll down to find Delete record 2 Press when the arrow is pointed beside D...

Страница 15: ...y enters Main Door DTMF setup Step 2 Set Main Door DTMF 1 Choose any digit between 0 and 9 This will become the designated touch tone number that opens the lobby door the factory default is 9 2 Press...

Страница 16: ...er You can now set the length of time that a visitor may talk with a resident 1 Enter time duration between 0 to 9999 seconds The factory default is 60 seconds 2 Press to save and continue Step 1 Sele...

Страница 17: ...play now returns to the programming menu Step 1 Select Change Password 1 Press scroll up or scroll down to find Change Password 2 Press when the arrow is beside Change Password The display enters Chan...

Страница 18: ...Programming 14...

Страница 19: ...15 Part 2 Scrolling Directory Programming...

Страница 20: ...pressing the key and after a one second delay the character will appear in the display For example to enter the last name Doe 1 Press 3 once for the letter D 2 Press 6 three times for the letter O 3 P...

Страница 21: ...be between 1 to 4 digits long 2 Press to save and continue Step 4 Enter Relay Code 1 Enter the relay code 2 Press to save and continue Step 5 Enter NSL ID 1 Enter the NSL ID 2 Press to save and conti...

Страница 22: ...at steps 1 through 7 Step 8 Enter Keyless Code If keyless codes are being used enter the 4 digit code Press to save and continue If keyless codes are not being used press to save and continue Step 9 E...

Страница 23: ...he resident s name enter it now see page 16 for instructions The name may be up to 15 characters long Press to save and continue If you do not want to change the resident s name press to continue Step...

Страница 24: ...contact your technician for assistance Step 8 Enter Elevator ID If elevator ID is not being used press to continue If elevator ID is being used please contact your technician for assistance Step 9 En...

Страница 25: ...step 2 To exit the Delete Record mode press to return to the programming menu Step 1 Enter Delete Record mode 1 Press scroll up or scroll down to find Delete record 2 Press when the arrow is pointed b...

Страница 26: ...in Door DTMF setup Step 2 Set Main Door DTMF 1 Choose any digit between 0 and 9 This will become the designated touch tone number that opens the lobby door The factory default is 9 2 Press to save and...

Страница 27: ...Set Online Timer You can now set the length of time that a visitor may talk with a resident 1 Enter time duration between 0 to 9999 seconds The factory default is 60 seconds 2 Press to save and contin...

Страница 28: ...turns to the programming menu Step 1 Select Change Password 1 Press scroll up or scroll down to find Change Password 2 Press when the arrow is beside Change Password The display enters Change Password...

Страница 29: ...eypad Navigation Instructions on how to use the keypad Non Scrolling Directory A paper directory that lists the residents of the building NSL No Subscriber Line When a visitor enters a resident s code...

Страница 30: ...Glossary 26...

Страница 31: ...following The online timer may be set for too short a duration While in programming mode check that the online timer is set to more than 30 seconds factory default is set to 60 seconds If the tenant...

Страница 32: ...l is located on the back of the keypad display board Adjust the potentionmeter counter clockwise for a darker display and clockwise for a lighter display Q Why is there no dial tone when a visitor cal...

Страница 33: ...User s Guide 29 Resident Directory Worksheet For your records photocopy this sheet and fill in the resident information Unit No Resident s Name Dial Code Relay Number Phone Type Keyless Entry Code Fl...

Страница 34: ...utside telephone line you will hear a distinct tone when a guest places a call to you Briefly push the hangup switch to answer the call This action will automatically put the outside telephone line on...

Страница 35: ......

Страница 36: ...5W3 Tel 905 660 4655 Fax 905 660 4113 Mircom 2005 Printed in Canada Subject to change without prior notice www mircom com Advanced Life Safety Solutions U S A 60 Industrial Parkway Cheektowaga NY 142...

Отзывы: