QMP-5100B and QMP-5101B Installation and Operation Instructions

9

of closed doors; and, smoke and heat detectors may not detect smoke or heat from fires on another level of the 
residence or building. 

Software

Most Mircom products contain software. With respect to those products, Mircom does not warranty that the 
operation of the software will be uninterrupted or error-free or that the software will meet any other standard of 
performance, or that the functions or performance of the software will meet the user’s requirements.  Mircom shall 
not be liable for any delays, breakdowns, interruptions, loss, destruction, alteration or other problems in the use of a 
product arising our of, or caused by, the software.

Every fire is different in the amount and rate at which smoke and heat are generated. Smoke detectors cannot 
sense all types of fires equally well. Smoke detectors may not provide timely warning of fires caused by 
carelessness or safety hazards such as smoking in bed, violent explosions, escaping gas, improper storage of 
flammable materials, overloaded electrical circuits, children playing with matches or arson. 

Even if the smoke detector or heat detector operates as intended, there may be circumstances when there is 
insufficient warning to allow all occupants to escape in time to avoid injury or death. 

•Alarm Notification Appliances

 

Alarm Notification Appliances such as sirens, bells, horns, or strobes may not warn people or waken someone 
sleeping if there is an intervening wall or door. If notification appliances are located on a different level of the 
residence or premise, then it is less likely that the occupants will be alerted or awakened. Audible notification 
appliances may be interfered with by other noise sources such as stereos, radios, televisions, air conditioners or 
other appliances, or passing traffic. Audible notification appliances, however loud, may not be heard by a hearing-
impaired person. 

Telephone Lines

 

If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods of time. Also 
the telephone lines may be compromised by such things as criminal tampering, local construction, storms or 
earthquakes. 

•Insufficient Time

There may be circumstances when the system will operate as intended, yet the occupants will not be protected from 
the emergency due to their inability to respond to the warnings in a timely manner. If the system is monitored, the 
response may not occur in time enough to protect the occupants or their belongings. 

•Component Failure

 

Although every effort has been made to make this system as reliable as possible, the system may fail to function as 
intended due to the failure of a component. 

•Inadequate Testing

 

Most problems that would prevent an alarm system from operating as intended can be discovered by regular testing 
and maintenance. The complete system should be tested as required by national standards and the Local Authority 
Having Jurisdiction and immediately after a fire, storm, earthquake, accident, or any kind of construction activity 
inside or outside the premises. The testing should include all sensing devices, keypads, consoles, alarm indicating 
devices and any other operational devices that are part of the system. 

•Security and Insurance

 

Regardless of its capabilities, an alarm system is not a substitute for property or life insurance. An alarm system 
also is not a substitute for property owners, renters, or other occupants to act prudently to prevent or minimize the 
harmful effects of an emergency situation. 

IMPORTANT NOTE: End-users of the system must take care to ensure that the system, batteries, telephone lines, 
etc. are tested and examined on a regular basis to ensure the minimization of system failure.  

Содержание QMP-5100B Series

Страница 1: ...ior notice U S A 42 20 Steve Reynolds Blvd Unit 17 Norcross Atlanta GA 30093 Tel 1 888 660 4655 Fax 1 888 660 4113 www mircom com QMP 5100B and QZP 5100 Series Firefighters Master Paging Module and An...

Страница 2: ......

Страница 3: ...oduction 1 Mounting 1 Labels 1 Paging Modules 2 Single Stage Operation 4 Two Stage Operation 4 QMP 5100B QMP 5101B Paging Wiring 5 QMP 5100B and QMP 5101B Paging Configuration 6 Paging Operation 7 QMP...

Страница 4: ...Contents ii...

Страница 5: ...io Paging Zones for ease of ribbon cable connection Labels Slide in labels which are supplied with the QMP 5100B and QMP 5101B as NP 776 E1 E2 English or F1 F2 French are to be separated and inserted...

Страница 6: ...ter Paging Module See also the section Paging Operation The QMP 5101B Master Paging Module has a ribbon cable connection to the first QZP 5101 Zone Module and wiring terminals for connection to the QI...

Страница 7: ...MPLIFIER TROUBLE CIRCUIT TROUBLE RESET LAMP TEST DIGITIZED MESSAGES P3 P2 SW1 SW2 1 8 1 1 1 8 S S MIC IN MIC OUT PTT IN PTT IN 24VDC INPUT 24VDC OUTPUT RS 485 INTERFACE INPUT I S I OUTPUT I S I CONNEC...

Страница 8: ...There are two buttons and three LEDs per Zone The middle amber LED beside the top button indicates Zone Trouble The upper green LED by the top button indicates whether that Zone is selected for Voice...

Страница 9: ...llowed The 120 ohm End of Line Resistor on the RS 485 Output terminals is removed on all except the last wired Module MIC MIC SHLD 18 22 AWG Twisted Shielded Pair RS485 RS485 SHLD 18 22 AWG Twisted Sh...

Страница 10: ...F OFF ERROR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 DIP Switch SW 1 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF OFF ON ON ON ON OFF OFF...

Страница 11: ...ve green LED illuminates steadily This LED will not function if the DIP Switch SW1 5 is set to ON Warden Page Indicates that the Warden Page function is active green LED illuminates steadily QMP 5100B...

Страница 12: ...operative while it does not have power Power interruptions of any length are often accompanied by voltage fluctuations which may damage electronic equipment such as a fire alarm system After a power i...

Страница 13: ...s televisions air conditioners or other appliances or passing traffic Audible notification appliances however loud may not be heard by a hearing impaired person Telephone Lines If telephone lines are...

Страница 14: ...s caused by failure to provide a suitable installation environment for the products damage caused by use of the products for purposes other than those for which it was designed damage from improper ma...

Страница 15: ...information is accurate as of the date of publishing and is subject to change or revision without prior notice at the sole discretion of the Company WARNING Mircom Technologies Ltd recommends that the...

Страница 16: ...5 660 4113 Mircom 2011 Printed in Canada Subject to change without prior notice www mircom com U S A 4575 Witmer Industrial Estates Niagara Falls NY 14305 Tel 888 660 4655 905 660 4655 Fax 905 660 411...

Отзывы: