70
7.2
Wire Routing
Figure 17 Wire Routing
Notes:
Maximum Loop Resistance Should Not Exceed 25 ohms.
Maximum Wiring Run indicates wiring distance out and back to the panel. The
resistance across the shorted wire should be less than 25 ohms.
Notes:
All external connections are power limited except for the AC connections to the
transformer. Transformer connections must be routed separately from all other
external connections using their own conduit.
i
i
This knockout is to be used
exclusively for TS-1 from
the Power Supply Board
This knockout is to be used
exclusively for AC Input
This knockout is to be
used exclusively for the
City Tie connection
All power limited wiring
shall be routed through
the remaining knockouts.