Step 12

After PVC cement has been applied, push the riser pipe into
the  bottom  fitting  and  align  with  the  “T”  fitting  so  the  “T”
fitting fits into the 1

1

/

4

” hole at the top of the riser pipe.

Step 13

Apply teflon tape sealer to the valve threads.

523548_Miraco_3410-4:Layout 1  3/19/14  11:47 PM  Page 6

Содержание MiraFount 3410-4

Страница 1: ...TIONS FOR MODEL 3410 4 READ CAREFULLY MIRACO A DIVISION OF AHRENS AGRICULTURAL INDUSTRIES INC BOX 686 GRINNELL IOWA 50112 PHONE 641 236 5822 TOLL FREE 1 800 541 7866 FAX 1 641 236 3341 523548_Miraco_3...

Страница 2: ...escription Dimensions Weight 3410 4 200 hd hogs 15 4 lift up lids 34 x 361 2 x 16 85 80 hd sows 834 insulated tube Miraco plastic valve with stainless steel rod and ends 523548_Miraco_3410 4 Layout 1...

Страница 3: ...ulated tube for heat wells This 30 long unit provides maximum protection for your water line Step 3 Attach anchor chips with 5 16 x 1 stainless steel bolts and tighhten Step 4 Place the tank over the...

Страница 4: ...6 With a pen or pencil make a mark on the fill line 23 4 below the top of the 4 outer fill pipe Step 7 The riser pipe is not glued into the bottom fitting Pull the riser pipe out of the bottom fitting...

Страница 5: ...pointed at 90 pointing to the short end of the tank Point the fitting toward the wall that s closest Step 10 Make any adjustments before the cement sets up Step 11 Using the same PVC cement apply it t...

Страница 6: ...the riser pipe into the bottom fitting and align with the T fitting so the T fitting fits into the 11 4 hole at the top of the riser pipe Step 13 Apply teflon tape sealer to the valve threads 523548_...

Страница 7: ...w so the valve is tight In most cases hand tight is sufficient If wrenches are required be careful not to over tighten Step 15 Install the bob float and arm with the brass thumb screw 523548_Miraco_34...

Страница 8: ...12 OR 16 DRAINAGE TILE OR TREATED PLYWOOD WITH STYROFOAM LINED WALLS OR INSULATED TUBE 3 4 PVC PIPE 1 05 0 D 523548_Miraco_3410 4 Layout 1 3 19 14 11 47 PM Page 8...

Страница 9: ...12 OR 16 DRAINAGE TILE OR TREATED PLYWOOD WITH STYROFOAM LINED WALLS OR INSULATED TUBE 3 4 PVC PIPE 1 05 0 D 523548_Miraco_3410 4 Layout 1 3 19 14 11 47 PM Page 9...

Страница 10: ...523548_Miraco_3410 4 Layout 1 3 19 14 11 47 PM Page 10...

Страница 11: ...e attended to immediatley This is good practice for any make of waterers 4 The MiraFount should be cleaned periodically especially the ones being used for hogs Mud can hamper the proper operation of t...

Страница 12: ...or omission including but not limited to acts of nature which affect the Miraco unit materially and adversely and are not attributable to Miraco This warranty is limited to the repair or replacement...