SpecIFIcaTIonS
pressures
Minimum maintained pressure:
0.1 bar
(10 kPa).
Maximum maintained pressure:
5.0 bar
(500 kPa).
Warning!
Exceeding the stated maximum maintained pressure could result in
excessive spray forces and possible damage to the product.
Installation must be carried out in accordance with these instructions, and must be
conducted by designated, qualified and competent personnel.
InSTallaTIon requIremenTS
1.
the soap dish supplied
must
be used to stop the showerhead from dropping
below the spill-over level of the bath or shower tray. Pass the hose through the
soap dish and ensure there is a minimum of 25 mm between the showerhead
and bath/tray spill-over level. this will prevent water supply contamination due
to back-siphonage.
2.
Installations
must
comply with UK water regulations/ Bye-laws (Scotland),
and Building and Plumbing regulations in force at the time of installation
3.
avoid layouts where the shower hose will be sharply kinked. this may reduce
the life of the hose.
4.
do not
fit any form of flow control in the shower outlet.
5.
do not
use excessive force when making connections.
6.
do not
install the fittings in a position where it could become frozen.
Soap Dish
25 mm Minimum
Spill-over level