INTRODUCTION
Thank you for purchasing a quality Mira product. To
enjoy the full potential of your new product, please
take time to read this guide thoroughly, having
done so, keep it handy for future reference.
These shower fittings are designed to give a
satisfactory shower over a range of pressures
between 0.1 and 5.0 bar.
1.
Mark the positions of the backplate fixing
holes.
Caution!
Be aware of hidden pipes or
cables.
2.
For solid walls drill the fixing holes for the
backplate with a 6 mm drill and insert the
wall plugs (supplied). For other types of wall
structure alternative fixings may be required
(not supplied).
Caution!
Take care not to drill into hidden
pipes or cables.
3.
Carefully fit the backplate over the outlet pipe
and secure with the fixing screws (supplied).
Caution!
Take care not to damage the ‘O’ Seal
in the back of the backplate.
Screws
Backplate
Wall Plugs
4.
Fit the olive and compression nipple over
the outlet pipe and tighten the compression
nipple.
Olive
Compression Nipple
5.
Fit the concealing shroud onto the shower arm.
6.
Fit the compression nut and olive onto the
shower arm.
INSTALLATION
General
1.
Make sure that the shower fittings are installed
by a competent installer.
2.
Installations must comply with Water Regulations
(Bye-Laws, Scotland), and any other Local
Regulations and Building Regulations in force
at the time of installation.
3.
Before installation carefully inspect the new
fixture for any signs of damage.
4.
The shower fittings should be positioned at a
convenient height for all the family and so that
the deluge head will discharge down the centre
of a bath or shower cubicle. Position the deluge
head to spray across rather than towards the
opening of the cubicle (if applicable) and also
away from the shower control.
5.
Special consideration should be given to the
fixing arrangements when installing onto a
dry lined, stud partition, shower cubicle or
laminated panel wall structures. Installers may
wish to obtain alternative proprietary cavity
fixings, or choose other options, however,
these methods of fixing are beyond the scope
of this guide.
Install the Shower Arm and Deluge
Head
The shower arm and deluge head must be fitted
after the installation of the shower control and the
outlet pipe must protrude 18 mm (± 2 mm) from
the finished wall surface. The outlet pipe must be
fitted at a suitable height and so that the deluge
head will discharge down the centre of a bath or
shower cubicle.