background image

7.

  Fit the shower arm into the compression nipple 

and tighten the compression nut.

8.

  Hand tighten the concealing shroud onto the 

backplate.

9.

  Screw the deluge head onto the shower arm, 

if necessary fit the flow regulator.

 

Important! 

Certain mixing valves may have 

flow regulators, refer to your shower control 

installation and user guide for details.

 

Caution! 

The shower arm is not designed to 

take weight, therefore care needs to be taken 
when installing the deluge head.

Shower Arm

Deluge Head

Flow Regulator 
(some models)

10.

 Turn on the shower control and check for leaks.

1656.132

Concealing 
Shroud

SPARE PARTS

MAINTENANCE

Cleaning

Warning!

 Many household cleaners contain 

abrasive and chemical substances, and should not 

be used for cleaning plated or plastic fittings.
These  finishes  should  be  cleaned  with  a  mild 

washing up detergent or soap solution, and then 
wiped dry using a soft cloth.
Use your thumb or a soft cloth to wipe any 
limescale from the soft nozzles and the front 
surface of the showerhead spray plate.

Do not 

use descalents on this product.

4.

  Remove the screws and backplate from the 

wallplate.

5.

  Drill the two backplate fixing holes, if necessary 

make a recess approximately 6 mm deep to 

accept the wallplate. Plug the two fixing holes.

6.

  Place the wallplate over the copper pipe and 

fix to the wall with the two wallplate screws.

7.

  Temporarily  fit  the  two  backplate  screws  to 

the wallplate. This will prevent the holes from 
becoming blocked with plaster and grout.

8.

  Finish the surface of the wall as required ensuring 

the pipework is protruding by 18 mm ± 2 mm.

9.

  Remove the two backplate screws.

10.

 Place the backplate against the finished wall 

surface and use the two backplate screws 

supplied to fix the backplate to the wallplate.

11.

 Follow steps 4 - 9 from previous section to 

complete the shower arm installation.

Alternative Installation procedure 
using the wallplate

1. 

Loosely screw the backplate to the wallplate 
with the two backplate screws provided.

2.

  Place the wallplate and backplate assembly 

over the copper pipe.

3.

  Mark the position of the wallplate and its fixing 

holes on the wall.

Concealing 
Shroud

Olive

Compression 
Nut

Shower 
Arm

Copper Pipe

Backplate

Backplate 
Screw

6 mm Recess

1656.131

Backplate Assembly

1660.161

 - Mira 18.5 cm (Chrome)

1799.007

 - Mira Beat 20 cm (Chrome

1799.008

 - Mira Beat 25 cm (White/Chrome)

Deluge Head

1799.009

Shower Arm

Отзывы: