Warning
IF YOU DETECT ANY CONTAMINANT ODOR OR TASTE, OR
IRRITATION OF EYES, NOSE OR THROAT THAT SUGGESTS
EXPOSURE TO THE CONTAMINANT, RETURN TO FRESH AIR
IMMEDIATELY. DETERMINE THE REASON FOR THE EXPOSURE
AND TAKE APPROPRIATE CORRECTIVE ACTION BEFORE
CONTINUING USE OF THE RESPIRATOR. FAILURE TO TAKE THE
PROPER CORRECTIVE ACTION MAY RESULT IN EXPOSURE TO
THE CONTAMINANT WHICH COULD CAUSE SERIOUS INJURY
OR DEATH.
Warning
IF BATTERY COMPARTMENT BECOMES HOT, IMMEDIATELY
LEAVE THE AREA REQUIRING RESPIRATORY PROTECTION,
TURN OFF THE EQUIPMENT, AND ALLOW THE BATTERIES TO
COOL AT LEAST 60 MINUTES BEFORE REMOVING IT. DO NOT
HANDLE BATTERY DIRECTLY IF YOU SMELL AN ACRID ODOR.
Warning
DO NOT REMOVE THE FACEPIECE,
BREATHING TUBE, OR ADAPTER
FROM THE FACEPIECE WHILE IN A
HAZARDOUS ATMOSPHERE EXCEPT
IN AN EMERGENCY. REMOVING ANY
OF THESE ITEMS WILL TERMINATE
RESPIRATORY PROTECTION AND
EXPOSE THE USER TO THE
HAZARDOUS ATMOSPHERE, WHICH
MAY RESULT IN SERIOUS INJURY OR
DEATH.
Termination of use occurs when the user leaves the contaminated area and does not
intend to reenter. Removal must be done in a fresh air environment after thorough
decontamination. To doff the facepiece
The MIRA Safety MB-90 PAPR must be cleaned, inspected, and prepared for its next use. Refer to the CLEANING AND
STORAGE section of this manual.
TERMINATION OF USE
Exit the area requiring respiratory protection and, if necessary, proceed to
decontamination as directed by your respiratory protection program.
1
Remove the blower assembly by disengaging the belt and removing the blower assembly from the belt.
3
Open the battery compartment by unthreading (counterclockwise) its cover and remove the batteries.
5
Unthread and remove the filter elements. Replace the cap and plug on each filter element. Do not dispose of filter
elements as ordinary waste. See DISPOSAL OF USED FILTER ELEMENTS in this manual.
4
When it is safe to remove the respirator and handle it:
2
Turn the power switch to the OFF position.
a
Remove the respirator facepiece as directed
by its instruction manual. Do not remove
the facepiece by pulling on the breathing
tube assembly.
b