The MIRA Safety MB-90 PAPR is intended for use as respiratory protection from airborne contaminants when used in 

conjunction with a filter and gas mask/full-face respirator.

1

The personnel using this respirator must have read this manual completely, and, ideally, received training from their 

employer or team leader prior to use. Each user must also have received training in the use of their existing respirator 

equipment including, but not limited to, pre-use check, donning, seal check, use, doffing and after-use care of the 

respirator.

2

To use this equipment, you must follow the instructions regarding the use of the filter and gas mask/full-face 

respirator you attach to it. Most (but not all) gas masks/full-face respirators are incompatible with facial hair. Beards, 

sideburns, and other facial hair must be shaved clean so the mask can securely seal around its edges. Likewise, most 

gas masks are not compatible with corrective lenses that could interfere with the seal. Consult your gas 

mask/full-face respirator instruction manual for details.

3

The individual using the respirator must ensure it is properly inspected before use, properly decontaminated after 

use (if necessary), properly cleaned and maintained after use, and properly stored between uses.

4

The MIRA Safety MB-90

 PAPR (when used with compatible gas mask/full-face respirator and filter) protects only the 

face and respiratory tract from airborne contaminants. Additional protective clothing, equipment, and headwear will 

often be required, though it must not interfere with the operation of the respirator.

5

Use in explosive atmospheres is NOT PERMITTED. The MIRA Safety MB-90 PAPR contains a battery and must not be 

taken into or used in atmospheres containing flammable or explosive gases, vapors, or dusts when the concentration 

of such contaminants constitutes a fire or explosion hazard.

6

The MIRA Safety MB-90 PAPR is NOT A TOY and should only be used according to the instructions herein. Do NOT 

use the MB-90

 PAPR for firefighting, in oxygen-deficient atmospheres, or for protection against contaminants that 

the filter elements do not protect against.

7

The MIRA Safety MB-90

 PAPR must NOT be used with expired or incompatible filter elements and/or gas masks.

8

Page 3

Содержание MB-90

Страница 1: ...MB 90 PoweredAir Purifying Respirator PAPR RD011721...

Страница 2: ......

Страница 3: ...EMENT NOT REPLACE EXISTING TRAINING AND PROTOCOL REGARDING THE USE OF PPE AND GAS MASKS FULL FACE RESPIRATORS PLEASE CONSULT LEADERSHIP OR RELEVANT AUTHORITIES REGARDING THE DEPLOYMENT OF THIS EQUIPME...

Страница 4: ...F power switch is on the top front of the blower assembly On the front there are two 2 threaded inlets to attach 40 mm filters The MIRA Safety MB 90 PAPR can use up to two 2 filters New filters must b...

Страница 5: ...respirator instruction manual for details 3 The individual using the respirator must ensure it is properly inspected before use properly decontaminated after use if necessary properly cleaned and mai...

Страница 6: ...on and that the batteries are fully charged Turn the power switch ON briefly to ensure the unit is functioning Turn the power switch OFF again 1 The blower assembly and breathing tube must be arranged...

Страница 7: ...rough the respirator and immediately leave the contaminated area Decontaminate and if necessary check the PAPR 16 Manually inspect the seals and junctions of your gas mask breathing tube and PAPR filt...

Страница 8: ...acepiece from the breathing tube or remove the facepiece THIS WILL TERMINATE RESPIRATORY PROTECTION AND THE USER WILL BE BREATHING THE ATMOSPHERE THE RESPIRATOR WAS INTENDED TO PROTECT AGAINST PERFORM...

Страница 9: ...R DEATH Termination of use occurs when the user leaves the contaminated area and does not intend to reenter Removal must be done in a fresh air environment after thorough decontamination To doff the f...

Страница 10: ...tridges please contact MIRA Safety Customer Service Your MIRA Safety MB 90 PAPR comes with an enclosed breathing tube If the tube is damaged or dysfunctional in any way contact MIRA Safety for a repla...

Страница 11: ...ecting sanitizing preparations used Used filter elements must be removed and disposed of as directed in the DISPOSAL OF USED FILTER ELEMENTS section of this manual CLEANINGANDSTORAGE Warning INSPECT T...

Страница 12: ...Rinse thoroughly with clean water 3 DO NOT STORE BATTERIES IN THE BLOWER UNIT Store AA batteries separately according to the manufacturer s guidance 1 Store the MIRA Safety MB 90 PAPR blower belt and...

Страница 13: ...purchase may be required 2 Return the product to the retailer where the product was purchased for an exchange provided that the store is a participating retailer Returns to a retailer should be made w...

Страница 14: ...1 N FM 620 RD STE 259 155 Austin TX 78726 2021 MIRA Safety LLC MIRA Safety the MIRA Safety logo and MB 90 are registered and or unregistered marks of MIRA Safety LLC or its affiliates 888 316 1462 sup...

Отзывы: