7
SPECIFICATIONS
European Conformity Information
Mira Sport range of showers complies with the following European directives:
2006/95/EC Low Voltage Directive, 2004/108/EC EMC Directive.
Mira Sport range of showers are high power appliance and are subject to
conditional connection. If the main electrical supply fuse is rated less than 80
Amps, the local electricity supply company must be contacted to confirm if the
electrical supply is adequate.
Mira Sport range of showers complies with the requirements of the UK’s water
regulations.
Dimensions
Height
340 mm
Width
204 mm
Depth
80 mm
Electrical
Variant
Sport 7.5
Sport 9.0
Sport 9.8
Nominal Power at 230 V ac
6.9 kW
8.3 kW
9.0 kW
Nominal Power at 240 V ac
7.5 kW
9.0 kW
9.8 kW
Recommended MCB Rating
40 A
40 A
45 A
Maximum Supply Cable Size
16 mm²
Recommended RCD Rating
30 mA tripping current
Recommended Isolator Switch
45 A double-pole with 3 mm contact separation
Appliance Sealing Rating
IP X4 - Suitable for installation in Zone 1
Maximum Ambient Temperature
30°C
Minimum Ambient Temperature
2°C
Plumbing
Variant
Sport 7.5
Sport 9.0
Sport 9.8
Minimum Dynamic Pressure
70 kPa
(0.7 bar)
70 kPa
(0.7 bar)
70 kPa
(0.7 bar)
Maximum Static Pressure
1000 kPa (10 bar)
Minimum Static Pressure
20 kPa (0.2 bar)
Maximum Inlet Temperature
30°C
Minimum Inlet Temperature
2°C
Inlet Connection
1/2” BSP Male / 15 mm Compression Fitting
Maximum Water Hardness
200 ppm CaCO
3
Outlet Connection
1/2” BSP Male