USER SAFETY INFORMATION

1.  Make sure that you fully understand how 

to operate this shower before use, read 

all operating instructions and retain this 

guide for future reference.

2.  This shower is not intended for use 

by  persons  (including  children)  with 

reduced physical, sensory or mental 

capabilities, or lack of experience and 

knowledge, unless they have been given 

supervision or instruction concerning 

the use of the shower by a person 

responsible for their safety.

3.  Children should be supervised to ensure 

that they do not play with the shower.

4. 

DO NOT

 switch the shower on if there is 

a possibility that the water in the shower 

is frozen.

5. 

DO NOT

 switch the shower on if water 

leaks from the shower unit. Isolate 

the electrical supply to the shower 

immediately.

6. 

DO NOT

 switch the shower on if 

the case appears to be damaged or 

incorrectly  fitted.  Isolate  the  electrical 

supply to the shower immediately. 

7.  Switch off the appliance at electrical 

isolating switch when not in use. This is 

for safety and is recommended with all 

electrical appliances.

8. 

DO NOT

 connect the outlet of the 

shower to any tap, control valve, trigger 

handset or showerhead other than those 

specified for use with this shower. Only 

Kohler Mira recommended accessories 

should be used. 

9. 

Always  check  the  water  temperature 

before entering the shower. Sunburn 

or skin conditions can increase your 

WARNING

 - 

THIS SHOWER CAN DELIVER SCALDING TEMPERATURES IF 

NOT OPERATED, INSTALLED OR MAINTAINED IN ACCORDANCE WITH THE 

INSTRUCTIONS, WARNINGS AND CAUTIONS CONTAINED IN THIS GUIDE AND 

ON OR INSIDE THE APPLIANCE. 

To reduce the risk of fire, electric shock or injury:

sensitivity to hot water. Make sure 

that you set the shower to a cooler 

temperature.

10. 

DO NOT

 operate the temperature 

control rapidly, allow 10 – 15 seconds for 

the temperature to stabilise before use.

11.  Care is required if the shower is turned 

off and back on during showering as 

this may result in unstable temperature. 

Ensure  temperature  has  stabilised 

before re-using shower.

12.  The showerhead must be de-scaled 

regularly, refer to the user maintenance 

section towards the rear of this guide 

for details.

13.  The shower hose must be checked 

regularly and replaced if damaged, refer 

to the user maintenance section towards 

the rear of this guide for details.

14. 

DO NOT 

store bathroom items on top of 

the shower unit (i.e. shampoo or shower 

gel containers).

15.  The shower must be operated and 

maintained in accordance with the 

requirements of this guide.

16.  If any of the following conditions occur, 

isolate the electricity and water supplies 

and contact Kohler Mira Customer 

Service.

• 

If the case is damaged or the cover 

is not correctly fitted and water has 

entered the shower case.

• 

If the shower begins to make an 

odd noise, smell or smoke. 

• 

If the shower shows signs of a 

distinct change in performance 

indicating a need for maintenance.

Содержание J95A

Страница 1: ...1 These instructions must be left with the user Installation Guide Mira Sport 7 5 9 0 9 8 kW...

Страница 2: ...Patents and Design Registration 3 Important Safety Information 4 Pack Contents Checklist 5 Wiring Diagram 6 Specifications 7 Plumbing 7 Electrical 7 Dimensions 7 Installation Requirements 8 Plumbing...

Страница 3: ...s guide Product Model Number Colour Mira Sport 7 5 J95A White Chrome Mira Sport 9 0 J95B J95V White Chrome Chrome Mira Sport 9 8 J95C J95W White Chrome Chrome Guarantee For domestic installations Mira...

Страница 4: ...bility that the water in the shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate the electrical supply to the shower immediately 7 DO NOT connect the ou...

Страница 5: ...f with the part names and to confirm that the parts are included q 3 x Wall Plugs q 1 x Compression Nut q 3 x Fixing Screws q 2 x Case Inserts q 1 x Olive q 1 x Mira Sport 7 5 9 0 or 9 8 Documentation...

Страница 6: ...BLACK BLUE BLUE GREEN GREEN BLACK RED RED RED Thermal Cutout Dual Disc L Solenoid Valve Pressure Power Selector Switch Low Flow Neon Power On Neon N E Tank Connection Inlet Connector Internal Wiring D...

Страница 7: ...ort 9 0 Sport 9 8 Nominal Power at 230 V ac 6 9 kW 8 3 kW 9 0 kW Nominal Power at 240 V ac 7 5 kW 9 0 kW 9 8 kW Recommended MCB Rating 40 A 40 A 45 A Maximum Supply Cable Size 16 mm Recommended RCD Ra...

Страница 8: ...and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted to a waterproof flat and...

Страница 9: ...itable Zone of Backflow Risk 30 mm Minimum Toilet or Bidet FC5 Hand Basin FC3 Bath or Shower Tray FC3 Electric Shower 25 mm Minimum 25 mm Minimum 15 A full bore non restrictive servicing valve must be...

Страница 10: ...ains system A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must...

Страница 11: ...Sport Attention Installer Caution Do not drill into buried cables or pipes Drill and plug the three holes using template R e m o v e c o v e r a n d determine supply pipe position For back inlet use s...

Страница 12: ...wires are clear of all mounting holes Refit the Service Tunnel and Cover Make sure they fit correctly Do not overtighten screws Do not use alternative screws to secure the Cover This can cause intern...

Страница 13: ...g COMMISSIONING Electrical supply is turned off at the mains Turn control to full cold Turn water supply fully on Check for water leaks Set control to LOW Switch on electrical supply Push START button...

Страница 14: ...l affect the tone This is quite normal in use Set control to HIGH _ The temperature will rise further Adjust temperature as required Flow rate will adjust automatically Press STOP and isolate power Th...

Страница 15: ...CTIONS The warmer the shower the lower the flow rate and vice versa _ COLD _ _ Hot water is produced by passing cold water through a heating tank The shower has three heater settings How Your Electric...

Страница 16: ...wer select HIGH Adjust the temperature as required The flow rate will adjust automatically The Effect of Seasonal Changes The Effect of Other Water Devices Showering temperature will stabilize to with...

Страница 17: ...burn or skin conditions can increase your WARNING THIS SHOWER CAN DELIVER SCALDING TEMPERATURES IF NOT OPERATED INSTALLED OR MAINTAINED IN ACCORDANCE WITH THE INSTRUCTIONS WARNINGSAND CAUTIONS CONTAIN...

Страница 18: ...un for a few seconds before stopping _ Switch on electrical supply Press START button Set to desired position Allow 10 15 seconds for any temperature adjustments to reach the handset _ Check water tem...

Страница 19: ...t double pole switch Fuse blown or MCB RCD tripped indicating possible electrical fault Switch on electrical s up p l y vi a the pullcord or wall mounted switch Renew the fuse or reset the MCB R C D I...

Страница 20: ...hut off Flow Valve faulty Min static pressure to ensure shut off and prevent dripping is 20 kPa 0 2 bar N o t e I f o t h e r appliances are operating static p r e s s u r e m a y drop below 20 k P a...

Страница 21: ...k excessively scaled Tu r n o ff o t h e r appliances whilst shower is in use Remove and clean Check case inserts are cut and fitted correctly Check services electrical or plumbing are not interferin...

Страница 22: ...not turn off ON ON OFF ON Any Any Flowvalve solenoid or Start Stop switch faulty Supply pressure b e l o w 2 0 k P a 0 2 bar R e p l a c e a s necessary Contact local water company Check mains water...

Страница 23: ...em of water Unscrew the hose from the showerhead and the shower outlet Inspect the hose Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning p...

Страница 24: ...sary Refit in reverse order making sure the Filter is screwed fully home Do not overtighten Make sure plumbing connections are sealed before restoring electricity supply Refit the cover making sure it...

Страница 25: ...embly 1563 513 Screw Pack components identified A 1563 514 Low Flow Neon Assembly 1563 515 Power On Neon Assembly 1563 516 Outlet Connector 1563 517 Service Tunnel 1563 518 Component Pack components i...

Страница 26: ...58 1563 517 1563 516 A A A B B B B B B B B B 1563 507 1563 519 1563 509 872 28 872 01 Important Push fit connectors must be assembled back to back onto terminals of micro switches A minimum air gap o...

Страница 27: ...002 Stylish slim line and robust shower seat for use in or outside of the shower area Folds up when not in use Maximum User Weight 150 kg 23 5 stone Note Must be installed onto a solid wall Logic Sho...

Страница 28: ...ee if simple home maintenance is required If you require further assistance call our Customer Services Team Extended Guarantees A selection of protection plans are available that enable you to cover r...